TITLE

Upgrade of the extraction system of permanent magnet electron cyclotron resonance ion source

AUTHOR(S)
Zhang, M.; Peng, S. X.; Ren, H. T.; Song, Z. Z.; Yuan, Z. X.; Zhou, Q. F.; Lu, P. N.; Xu, R.; Zhao, J.; Yu, J. X.; Chen, J. E.; Guo, Z. Y.; Lu, Y. R.
PUB. DATE
February 2010
SOURCE
Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B715
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A set of new ion extraction electrodes have been designed for the permanent magnetic electron cyclotron resonance ion source at Peking University to improve beam quality and transmission. PBGUNS has been used to optimize the extraction electrodes and simulate the beam behavior at the extraction region. The experiments showed that with the new system, the beam half divergence angle can be less than 40 mrad and the normalized rms emittance is about 0.13Ï€ mm mrad when the extracted current is 100 mA at 50 keV in pulse mode. The voltage of the suppression electrode has great effect on beam divergence. The effect of the microwave power and gas flow is also studied.
ACCESSION #
48352523

 

Related Articles

  • Effect of the plasma electrode position on the beam intensity and emittance of the RIKEN 18 GHz ECRIS. Higurashi, Y.; Nakagawa, T.; Kidera, M.; Aihara, T.; Kase, M.; Yano, Y. // AIP Conference Proceedings;2005, Vol. 749 Issue 1, p71 

    We measured the beam intensity of Ar, Kr and Xe ions as a function of plasma electrode position. The beam intensities of lower charge state heavy ions increased when moving the plasma electrode toward the ECR zone. The RF power absorbed in the plasma chamber was slightly dependent on the gas...

  • Design aspects of the Debrecen ECR ion source. Biri, S.; Vamosi, J. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p971 

    Reports on the design and construction of the Debrecen electron cyclotron resonance ion source. Functions of the coil and hexapole of the magnetic system; Function of the independent cooling system; Functions of the extraction-focusing electrode system; Capabilities of the TrapCAD code.

  • Improved ion extraction from an electron cyclotron resonance ion source by a metal-dielectric-extraction electrode. Schachter, L.; Dobrescu, S.; Stiebing, K. E. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A905 

    The goal of the experiment was to study the influence and the physics of the boundary region (between the plasma and the extraction potential) with direct impact on the source ion-beam output. A specially processed high-emissive metal-dielectric structure was installed on the extraction...

  • Spatially resolved charge-state and current-density distributions at the extraction of an electron cyclotron resonance ion source. Panitzsch, Lauri; Peleikis, Thies; Stalder, Michael; Wimmer-Schweingruber, Robert F. // Review of Scientific Instruments;Sep2011, Vol. 82 Issue 9, p093302 

    In this paper we present our measurements of charge-state and current-density distributions performed in very close vicinity (15 mm) of the extraction of our hexapole geometry electron cyclotron resonance ion source. We achieved a relatively high spatial resolution reducing the aperture of our...

  • Experiments with biased side electrodes in electron cyclotron resonance ion sources. Drentje, A. G.; Kitagawa, A.; Uchida, T.; Rácz, R.; Biri, S. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    The output of highly charged ions from an electron cyclotron resonance ion source (ECRIS) consists of ionic losses from a highly confined plasma. Therefore, an increase of the output of the ions of interest always is a compromise between an increase in the confinement and an increase of the...

  • A mode converter to generate a Gaussian-like mode for injection into the VENUS electron cyclotron resonance ion source. Lyneis, C.; Benitez, J.; Hodgkinson, A.; Plaum, B.; Strohmeier, M.; Thuillier, T.; Todd, D. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    A number of superconducting electron cyclotron resonance (ECR) ion sources use gyrotrons at either 24 or 28 GHz for ECR heating. In these systems, the microwave power is launched into the plasma using the TE01 circular waveguide mode. This is fundamentally different and may be less efficient...

  • Status of the multiply charged heavy-ion source MINIMAFIOS. Geller, R.; Jacquot, B.; Pontonnier, M. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1505 

    The principles, construction, and performance of the MINIMAFIOS electron cyclotron resonance ion source (ECRIS) are reviewed. The source can operate either pulsed, with pulse width of >50 ms, or cw, with 1011 fully stripped light ions per second and much higher amounts of lower charge state...

  • Enhanced ECR ion source performance with an electron gun. Xie, Zuqi; Lyneis, C. M.; Lam, R. S.; Lundgren, S. A. // Review of Scientific Instruments;Mar91, Vol. 62 Issue 3, p775 

    An electron gun for the advanced electron cyclotron resonance (AECR) source has been developed to increase the production of high charge state ions. The AECR source, which operates at 14 GHz, is being developed for the 88-in. cyclotron at Lawrence Berkeley Laboratory. The electron gun injects 10...

  • 18 GHz upgrading of the superconducting electron cyclotron resonance ion source SERSE. Gammino, S.; Ciavola, G.; Celona, M.; Castro, F.; Chines, F.; Marletta, S. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3577 

    Discusses an 18 GHz upgrading of the superconducting electron cyclotron resonance ion source SERSE of INFN-Laboratori Nazionali del Sud. Extension of the validation of high B mode to higher frequency; Role of the magnetic field and frequency on the ion yield at higher levels.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics