TITLE

Experimental study of a low radio frequency power driven relativistic klystron amplifier

AUTHOR(S)
Zheng-Hong Li
PUB. DATE
February 2010
SOURCE
Physics of Plasmas;Feb2010, Vol. 17 Issue 2, p023113
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Using particle in cell simulation codes, a low radio frequency (rf) power driven relativistic klystron amplifier is designed according to the beam with current of 7.5 kA and voltage of 750 kV with special measures to avoid the mode competition. Simulated power reaches 1.7 GW when the driven rf power is 7.0 kW, the corresponding gain is 53.9 dB. Also the experiment is carried out on a telsa-typed accelerator, whose beam is with current of 8 kA and voltage of 800 kV. The measured rf output power reaches 2.04 GW in the experiment when the input rf power is 62 kW and frequency 2.850 GHz, the corresponding gain is 45.1 dB and efficiency is 32%. The maximum gain reaches 46.7 dB when the input decreases to 39 kW, the corresponding output rf power is 1.84 GW.
ACCESSION #
48352259

 

Related Articles

  • VUCC.  // QST;Aug2005, Vol. 89 Issue 8, p49 

    Reports that the VHF/UHF Century Club is the counterpart to DXCC for the bands 50 megahertz to 300 gigahertz.

  • radio frequency.  // American Heritage Student Science Dictionary;2009, p286 

    A definition for "radio frequency" is presented. It refers to a frequency at which radio waves can be transmitted, ranging from extremely low frequency, below 300 hertz, to extremely high frequency, between 30 and 300 gigahertz.

  • The road to the Radio Synoptic SKA (RSSKA). Myers, Steven T. // AIP Conference Proceedings;8/15/2008, Vol. 1035 Issue 1, p310 

    The next generation of radio arrays are being designed under the umbrella of the “Square Kilometer Array” (SKA) project. The leading concept for a “mid-frequency” (0.3–10 GHz) array is a large wide-field Radio Synoptic SKA (RSSKA), which is being developed for...

  • Determination of Harmonic-Transfer-Matrices by Simulation. Müller, R.; Jentschel, H.-J. // Advances in Radio Science;2005, Vol. 3, p349 

    In this paper a method to obtain harmonic transfer matrices (HTM) from simulated or measured values (signature & signature response) is presented. These matrices subserve a description of complex systems (e.g. RF front-ends) with real properties, which can't be specified by simple analytic...

  • Characterization of Iridium Thin Films for TES Microcalorimeters. D. Bogorin; M. Galeazzi // Journal of Low Temperature Physics;Apr2008, Vol. 151 Issue 1/2, p167 

    Abstract  We are developing transition edge sensors (TES) using single layer iridium (Ir) as the detector and deposited tin (Sn) as the absorber. We obtained good Ir devices with reproducible and uniform transition temperature around 120 mK, transition widths of...

  • Remote actuation of a mechanical resonator. Hatanaka, D.; Mahboob, I.; Yamaguchi, H. // Applied Physics Letters;9/5/2011, Vol. 99 Issue 10, p103105 

    A micron-sized mechanical resonator is placed inside a coil operating at radio frequencies (RFs). The mechanical response is highly sensitive to continuous RF irradiation with the observation of both resonance frequency and quality factor shifts. If the RF amplitude is modulated at the natural...

  • Second harmonic acoustic responses induced in matter by quasi continuous radiofrequency fields. Kellnberger, Stephan; Omar, Murad; Sergiadis, George; Ntziachristos, Vasilis // Applied Physics Letters;10/7/2013, Vol. 103 Issue 15, p153706 

    We subjected conductive matter and tissue to intermittent continuous-wave radiofrequency fields and investigated whether acoustic responses could be recorded. By placing samples in the near-field of the excitation, we observed frequency-domain acoustic responses from tissues responding to CW...

  • GESTURENAIL:WIRELESS HAND GESTURE SYSTEM. Emi Tamaki; Ken Iwasaki // International Journal of Computer Science, Engineering & Applica;Oct2013, Vol. 3 Issue 5, p29 

    The hand gesture input systems will be adopted for use in many applications anytime and anywhere. In this research, a stating notification when and where a user can start using hand gestures for input are focused. However existing devices and systems could be used only in certain situations...

  • Application of radionics on primary and metastatic tumours of the liver. Andreadis, E.; Saliangas, K.; Economou, A.; Nikoloudis, N.; Manna, I.; Prodromou, K.; Siminou, S.; Chrissidis, T. // Techniques in Coloproctology;Nov2004 Supplement 1, Vol. 8, ps184 

    The aim of our study is to present our initial experience on the use of radiofrequency ablation (RFA) on hepatic tumours. Four patients with tumours of the liver were submitted to RFA. The first patient underwent an emergency left lobectomy due to rupture of a tumour of the left hepatic lobe. A...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics