TITLE

ADC enables temperature-compensated weigh-scale measurements

AUTHOR(S)
Travis, Bill; Swager, Anne Watson
PUB. DATE
July 2001
SOURCE
EDN;7/5/2001, Vol. 46 Issue 15, p126
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
Describes an analog to digital converter (ADC) that enables temperature-compensated weigh-scale measurements. Simultaneous measurement of both the temperature of the bridge and the primary output of the bridge transducer; Solution to the throughput problem that uses the two independent channels of an AD7719 dual sigma-delta ADC.
ACCESSION #
4798092

 

Related Articles

  • Connect temperature sensors to an ADC. Rose, Martin // Test & Measurement World;Sep2005, Vol. 25 Issue 8, p21 

    Discusses the procedure of connecting temperature sensors to an analog-to-digital converter (ADC). Usefulness of resistance-temperature detectors or thermistor as a cold-junction compensator to measure the temperature where the thermocouple wires when connecting thermocouples to ADC; Requirement...

  • Fine wire resistance thermometer amplifier for atmospheric measurements. Harrison, R. G.; Rogers, G. W. // Review of Scientific Instruments;Nov2006, Vol. 77 Issue 11, p116112 

    An improved amplifier for atmospheric fine wire resistance thermometry is described. The amplifier uses a low excitation current (50 μA). This is shown to ensure negligible self-heating of the low mass fine wire resistance sensor, compared with measured nocturnal surface air temperature...

  • An investigation of the acoustic properties of materials for ultrasonic thermometry. Zalutskaya, T.; Likhnovsky, I.; Lutsyk, Ya. // Measurement Techniques;Sep2012, Vol. 55 Issue 6, p676 

    The results of investigations of the acoustic properties of materials for ultrasonic thermometry are presented. Research apparatus based on a high-speed analog-to-digital converter is used.

  • Alternatives to Phase Map Thermometry: Apparent Diffusion Coefficient and Spectroscopy. Todd, Nick; Jeong, E. K.; Parker, Dennis L. // AIP Conference Proceedings;2007, Vol. 911 Issue 1, p289 

    Many investigators have settled on phase map thermometry as the best way to create the real time temperature maps that aid ablation treatments. The phase map technique is fast and accurate but encounters problems when run under non-ideal conditions. Presented here are two alternative methods for...

  • High resolution space quartz-flexure accelerometer based on capacitive sensing and electrostatic control technology. Tian, W.; Wu, S. C.; Zhou, Z. B.; Qu, S. B.; Bai, Y. Z.; Luo, J. // Review of Scientific Instruments;Sep2012, Vol. 83 Issue 9, p095002 

    High precision accelerometer plays an important role in space scientific and technical applications. A quartz-flexure accelerometer operating in low frequency range, having a resolution of better than 1 ng/Hz1/2, has been designed based on advanced capacitive sensing and electrostatic control...

  • Tethered Swimming as an Evaluation Tool of Single Arm-Stroke Force. Toubekis, A. G.; Gourgoulis, V.; Tokmakidis, S. P. // XIth International Symposium for Biomechanics & Medicine in Swim;2010, Issue 11, p296 

    Eight competitive swimmers performed a series of maximum intensity tethered swimming tests using full-stroke, arms only, right and left arm only. In all tests, the force of each arm-stroke was determined. The validity of each arm-stroke separation was tested in advance using overwater and...

  • Methods of Correcting Frequency Errors in Time-Type Analog-to-Digital Displacement Transducers. Potomskii, S.; Kosinsksii, A. // Measurement Techniques;Dec2014, Vol. 57 Issue 9, p973 

    An optoelectronic time-type displacement transducer with different methods of correction of frequency errors is considered. It is shown that the use of an automatic frequency control loop represents the most promising method. A functional circuit of the device is developed and the basic...

  • Study on Wireless Weighing System. Changbao Wen; Lihong Gao; Yingfei Fu; Yanming Li; Yongfeng Ju // Applied Mechanics & Materials;2014, Issue 644-650, p1365 

    In order to achieve the wireless operation of the data collected and system monitoring in the weighing equipment, a wireless weighing system design was proposed. This scheme combines with the weighing control technology and the wireless communications technology. The weighing system includes the...

  • Design and implementation of digital piezoelectric constant testing system. Bizheng Dong; Denghua Li // Applied Mechanics & Materials;2014, Issue 668-669, p911 

    Digital piezoelectric constant testing system was designed in this paper, which was based on hydrostatic test method. The system is composed of hydrostatic device, charge amplifier circuit, peak holding circuit, A/D calibration circuit, data processing by DSP. Pressure-release value is obtained...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library