TITLE

A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators

AUTHOR(S)
Jirschik, Mario; Keyl, Cornelius; Beyersdorf, Friedhelm
PUB. DATE
November 2009
SOURCE
Perfusion;Nov2009, Vol. 24 Issue 6, p423
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Microbubbles generated during heart surgery on extracorporeal circulation have been implicated as a possible cause of postoperative neurocognitive dysfunction and negative outcome. The main sources of microbubbles in the extracorporeal circuit are air leaking from the venous cannulation site, air delivered by drug and volume administration, during the taking of blood samples, during hemofiltration, and by using vacuum-assisted venous drainage (VAVD). Membrane oxygenators, although not designed for the elimination of gaseous microbubbles, can eliminate much of this air. Aim of the study / hypothesis: The aim of this study was to test the hypothesis that the amount of microbubbles passing through the oxygenator varies depending on the oxygenator design. Methods: one hundred patients undergoing aortic valve replacement with cardiopulmonary bypass (CPB) were included in a retrospective clinical trial assessing the bubble elimination of the two oxygenators routinely used in our clinic. The oxygenators (Quadrox-i Adult / Polystan Safe Maxi) are manufactured with the same hollow-fiber material, but display different designs. Bubbles were detected by a two-channel ultrasound bubble counter. The probes were placed directly at the inlet and the outlet of the oxygenators. The filtration index was calculated by the bubble counter as a measure of the percentage reduction of bubble volume and number. Results: The Quadrox has a significantly higher filtration index (92.3% [89.7; 95.1], median [25th,75th percentile]) than the Polystan (74.9% [64.2;80.9], p<0.001), indicating the superior ability of the Quadrox to eliminate microbubbles. Conclusion: Our study demonstrates major differences in the capacity of bubble elimination of the oxygenators being investigated, possibly depending on oxygenator design.
ACCESSION #
47781238

 

Related Articles

  • Postoperative Morbidity Following Red Cell Deformability Changes During Cardiopulmonary Bypass Using Bubble and Membrane Oxygenators. Belboul, Ali; Khaja, Najib Al; Bergman, Per; Roberts, Donald; William-Olsson, Göran // Vascular Surgery;Jul/Aug1989, Vol. 23 Issue 4, p258 

    The preoperative blood cell trauma and postoperative morbidity were compared in a prospective randomized study in two groups of patients undergoing cardiac surgery with extracorporeal circulation (ECC). One group was oxygenated during ECC with a membrane oxygenator (MO) and the other with a...

  • Cardiac ECMO for biventricular hearts after paediatric open heart surgery. Chaturvedi, R. R.; Macrae, D.; Brown, K. L.; Schindler, M.; Smith, E. C.; Davis, K. B.; Cohen, G.; Tsang, V.; Elliott, M.; de Leval, M.; Gallivan, S.; Goldman, A. P. // Heart;May2004, Vol. 90 Issue 5, p545 

    Objective: To delineate predictors of hospital survival in a large series of children with biventricular physiology supported with extracorporeal membrane oxygenation (ECMO) after open heart surgery.Results: 81 children were placed on ECMO after open heart surgery. 58%...

  • Renal medullary hypoxia during experimental cardiopulmonary bypass: a pilot study. Stafford-Smith, Mark; Grocott, Hilary P. // Perfusion;Jan2005, Vol. 20 Issue 1, p53 

    Objectives: To determine the effect of cardiopulmonary bypass (CPB) on renal medullary oxygenation. Design: Observational. Setting: Laboratory. Participants: Pigs (n=3). Interventions: Following induction of general anesthesia, a ParatrendTM blood gas probe was placed directly into the left...

  • Development of an instrument to indirectly monitor arterial pCO2 during cardiopulmonary bypass. Høgetveit, Jan Olav; Kristiansen, Frode; Pedersen, Thore H // Perfusion;Jan2006, Vol. 21 Issue 1, p13 

    Arterial blood carbon dioxide tension (PaCO2) during cardiopulmonary bypass (CBP) is important to the conduct of perfusion with alpha-stat or pH-stat strategy. Temperature changes during CBP complicate any attempts to monitor carbon dioxide tension in the exhaust outlet of an oxygenator (PexCO2)...

  • Cerebral oxygen saturation changes during modified ultrafiltration. Medlin, William M.; Sistino, Joseph J. // Perfusion;Nov2006, Vol. 21 Issue 6, p325 

    Background: A number of adverse effects are associated with the use of cardiopulmonary bypass (CPB) in pediatric patients undergoing cardiac surgery. Pulmonary compliance and gas exchange are decreased, and myocardial edema may result in diastolic dysfunction. Modified ultrafiltration (MUF)...

  • Comparison of hollow-fiber membrane oxygenators with different perfusion modes during normothermic and hypothermic CPB in a simulated neonatal model. Ündar, Akif; Bingyang Ji; Lukic, Branka; Zapanta, Conrad M.; Kunselman, Allen R.; Reibson, John D,; Khalapyan, Tigran; Baer, Larry; Weiss, William J.; Rosenberg, Gerson; Myers, John L. // Perfusion;Nov2006, Vol. 21 Issue 6, p381 

    Purpose: The objectives of this investigation were (1) to compare two hollow-fiber membrane oxygenators (Capiox Baby RX versus Lilliput 1-D901) in terms of pressure drops and surplus hemodynamic energy (SHE) during normothermic and hypothermic cardiopulmonary bypass (CPB) in a simulated neonatal...

  • Interleukin-6 may predict survival in extracorporeal membrane oxygenation treatment. Risnes, I.; Wagner, K.; Ueland, T.; Mollnes, T. E.; Aukrust, P.; Svennevig, J. L. // Perfusion;May2008, Vol. 23 Issue 3, p173 

    The cytokine network and its association with complement activation during cardiac surgery with cardiopulmonary bypass (CPB) is complex. Extracorporeal membrane oxygenation (ECMO) differs from CPB in duration of days to weeks rather than hours. However, few studies have analyzed the levels of...

  • Does CO2 flushing of the empty CPB circuit decrease the number of gaseous emboli in the prime? Nyman, J.; Rundby, C.; Svenarud, P.; van der Linden, J. // Perfusion;Jul2009, Vol. 24 Issue 4, p249 

    Twenty (20) CPB-circuits were randomized to a CO2 group or a control group. In the CO2 group, each circuit was flushed with CO2 (10L/min) at the top of the venous reservoir for 5 minutes, after which priming fluid was added without interruption of the CO2 inflow. Control group circuits were not...

  • Effects of centrifugal and roller pumps on survival of autologous red cells in cardiopulmonary bypass surgery. Valeri, C. R.; MacGregor, H.; Ragno, G.; Healey, N.; Fonger, J.; Khuri, S. F. // Perfusion;Sep2006, Vol. 21 Issue 5, p291 

    Background: Either a roller pump or a centrifugal pump can be used in the extracorporeal circuit during surgery with cardiopulmonary bypass. In this study, we assessed the effect of these two pumps on the 24-h post-transfusion survival values of autologous red blood cells (RBC). Study design and...

Share

Read the Article

Courtesy of

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics