TITLE

Feasibility and applicability of integrated metrology using spectroscopic ellipsometry in a cluster tool

AUTHOR(S)
Piel, J. Ph.; Boher, P.; Stehle┬┤, J. L.; Pickering, C.
PUB. DATE
January 2001
SOURCE
AIP Conference Proceedings;2001, Vol. 550 Issue 1, p538
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
For any industrial integrated metrology application three key issues must be addressed - feasibility, applicability and cost-effectiveness. This paper reports progress on the integration of spectroscopic ellipsometry (SE) in the cool-down chamber. SE is capable of providing rapid information on layer thickness, composition, crystallinity, surface roughness, etc. However, major issues remain to be addressed for integration in commercial tools, including development of compact hardware with high stability and accuracy to fit in the accessible space, automatic alignment and movement systems, and calibration of chamber access windows. Potential uses of integrated metrology are for rapid process development, evaluation of in situ cleaning, measurement of multiple processes without exposure to atmosphere, accurate measurement of layers obscured by later processing, run-to-run, chamber-to-chamber and tool-to-tool repeatability and control, evaluation of cross-wafer uniformity, go/no go decision making after each process step (reducing wafer wastage) and early fault detection.
ACCESSION #
4759627

 

Related Articles

  • Soft x-ray multilayer phase shifter. Yamamoto, M.; Yanagihara, M.; Nomura, H.; Mayama, K.; Kimura, H. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1510 

    Phase shift versus incident angle characteristics of soft x-ray multilayer mirrors have been studied for the first time by rotating analyzer ellipsometry at 97 eV photon energy. Synchrotron radiation was used as a linear polarization source and a multilayer polarizer of 97% polarizance was used...

  • Ellipsometrical determination of the optical constants of gold in the vacuum ultraviolet region. Kandaka, Noriaki; Yuri, Masatada; Fukutani, Hirohito; Koide, Tsuneharu; Shidara, Tetsuo // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1450 

    An ellipsometer has been designed and constructed for use in the vacuum ultraviolet region. To test the performance of the ellipsometer, the optical constants of Au were determined in the energy region 15-28 eV. The theoretical background and the experimental procedures of our ellipsometer are...

  • Active low frequency vertical vibration isolation. Hensley, Joel M.; Peters, Achim; Chu, Steven // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2735 

    Describes the construction of a system that isolates a key element of an experimental setup from vertical motions of the ground and the surrounding apparatus. Theory; Mechanical system; Electronic feedback; Alignment.

  • Three-in-one functionality. whitel // MWP (Online Edition);10/ 4/2012, p207 

    The article evaluates Talyrond 500 instruments for roundness, form and surface finish measurements.

  • Transverse Kerr magneto-optic measurements with a rotating analyzer ellipsometer. Minden, H. T. // Review of Scientific Instruments;Jun92, Vol. 63 Issue 6, p3290 

    The use of a rotating analyzer ellipsometer is proposed to measure the spectral variation of the transverse Kerr magneto-optic effect. A low inductance coil is placed close to the sample in such a way that an alternating magnetic field is applied in the plane of the sample and perpendicular to...

  • A liquid nitrogen immersion cryostat for optical measurements. Andrews, Steven S.; Boxer, Steven G. // Review of Scientific Instruments;Sep2000, Vol. 71 Issue 9 

    A liquid nitrogen immersion cryostat has been developed for optical measurements. Liquid nitrogen in the sample chamber is kept free of bubbles and schlieren by the use of a cooling jacket of sacrificial liquid nitrogen, which is kept at a lower pressure than the sample chamber. This design has...

  • New Literature.  // Physics Today;Apr88, Vol. 41 Issue 4, p107 

    Features catalog of scientific instruments from different companies. 1988 catalog of vacuum equipment from Perkin-Elmer Corp.'s Physical Electronics Division; Catalog of instruments for making resistance versus temperature measurements on high-temperature superconductors from Keithley Instruments.

  • Goniometric optical scatter instrument for out-of-plane ellipsometry measurements. Germer, Thomas A.; Asmail, Clara C. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3688 

    Describes a goniometric optical scatter instrument developed at the National Institute of Standards and Technology which can perform measurements of optical scatter and its associated polarization in directions out of the plane of incidence. Coordinate transformations required to operate such a...

  • New design of the variable angle infrared spectroscopic ellipsometer using double Fourier transforms. Xia, Guo-Qiang; Guo-Qiang Xia; Zhang, Rong-Jun; Rong-Jun Zhang; Chen, Yu-Li; Yu-Li Chen; Zhao, Hai-Bing; Hai-Bing Zhao; Wang, Song-You; Song-You Wang; Zhou, Shi-Ming; Shi-Ming Zhou; Zheng, Yu-Xiang; Yu-Xiang Zheng; Yang, Yue-Mei; Yue-Mei Yang; Chen, Liang-Yao; Liang-Yao Chen; Chu, Jun-Hao; Jun-Hao Chu // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    A new type of incidence-angle-variable infrared spectroscopic ellipsometer working in the 2100-10 000 wave number range has been designed and constructed. For the system, the analyzer and polarizer were driven by two microstepping motors having hollow shafts and rotating synchronously with a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.