TITLE

Cardioplegia heat exchanger design modelling using computational fluid dynamics

AUTHOR(S)
van Driel, Michael R.
PUB. DATE
October 2000
SOURCE
Perfusion;Oct2000, Vol. 15 Issue 6, p541
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new cardioplegia heat exchanger has been developed by Sorin Biomedica. A three-dimensional computer-aided design (CAD) model was optimized using computational fluid dynamics (CFD) modelling. CFD optimization techniques have commonly been applied to velocity flow field analysis, but CFD analysis was also used in this study to predict the heat exchange performance of the design before prototype fabrication. The iterative results of the optimization and the actual heat exchange performance of the final configuration are presented in this paper. Based on the behaviour of this model, both the water and blood fluid flow paths of the heat exchanger were optimized. The simulation predicted superior heat exchange performance using an optimal amount of energy exchange surface area, reducing the total contact surface area, the device priming volume and the material costs. Experimental results confirm the empirical results predicted by the CFD analysis.
ACCESSION #
4747975

 

Related Articles

  • Intermittent antegrade warm myocardial protection compared to intermittent cold blood cardioplegia in elective coronary surgery – do we have to change? Franke, Ulrich F.W.; Korsch, Simone; Wittwer, Thorsten; Albes, Johannes M.; Wippermann, Jens; Kaluza, Mirko; Rahmanian, Parwis B.; Wahlers, Thorsten // European Journal of Cardio-Thoracic Surgery;Mar2003, Vol. 23 Issue 3, p341 

    Objective: Intermittent antegrade warm blood cardioplegia (IAWBC) is a simple and cost-effective method of myocardial preservation. However, there are only few prospective trials comparing this type of cardioplegia to established cardioplegic strategies in elective on-pump coronary surgery with...

  • Myocardial protection in adult cardiac surgery: current options and future challenges Nicolini, Francesco; Beghi, Cesare; Muscari, Claudio; Agostinelli, Andrea; Maria Budillon, Alessandro; Spaggiari, Igino; Gherli, Tiziano // European Journal of Cardio-Thoracic Surgery;Dec2003, Vol. 24 Issue 6, p986 

    Current techniques of myocardial protection are evolving with the use of less conventional modalities of cardioplegia and have reduced the morbidity and mortality of cardiac operations. Blood cardioplegic solutions appear superior to cold cardioplegia in terms of myocardial protection and...

  • Cardioplegia and ventricular late potentials in cardiac surgical patients. Schütz, N.; Romand, J.; Yanez, N.; Treggiari, M.; Bendjelid, K. // Journal of Clinical Monitoring & Computing;Aug2011, Vol. 25 Issue 4, p269 

    Background and objective: Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial...

  • Deals roundup.  // Medical Device Daily;12/2/2008, Vol. 12 Issue 233, p9 

    The article discusses the plan of Sorin Group to acquire Datascope's Clearglide endoscopic vessel harvesting product line. Factors that must be satisfied prior to the closing of the transaction are mentioned, including the acquisition deal between Datascope and Getinge. Upon completion of the...

  • Med-Tech Notes.  // Medical Device Daily;9/20/2013, Vol. 17 Issue 182, p4 

    The article reports that Emory Heart & Vascular Center in Atlanta, Georgia has performed its first implant of an eSVS mesh on September 4, 2013 as part of a clinical trial for the device by its developer Kips Bay Medical.

  • Sorin Group reports market release of new CRT-D system.  // Medical Device Daily;12/4/2008, Vol. 12 Issue 235, p2 

    The article reports on the commercial launch of Paradym CRT 8750 cardiac resynchronization therapy defibrillator (CRT-D) by Sorin Group in December 2008.

  • Sorin releases Reply pacemakers.  // Medical Device Daily;5/21/2007, Vol. 11 Issue 97, p7 

    The article reports on the release of the Reply cardiac pacemakers by Sorin in Europe in May 2007.

  • Sorin Group releases new CRT-D system.  // Cardiovascular Devices & Drugs;Jan2009, Vol. 15 Issue 1, p22 

    The article evaluates the Paradym CRT 8750 cardiac resynchronization therapy defibrillator (CRT-D) from Sorin Group.

  • Sorin Group releases new CRT-D system.  // Biomedical Business & Technology;Jan2009, Vol. 32 Issue 1, p35 

    The article evaluates the Paradym CRT 8750 cardiac resynchronization therapy defibrillator (CRT-D) from Sorin Group.

Share

Read the Article

Courtesy of NEW JERSEY STATE LIBRARY

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics