TITLE

Unstable trochanteric fractures: the role of lateral wall reconstruction

AUTHOR(S)
R. Gupta; Kapil Sangwan; Pradeep Kamboj; Sarabjeet Punia; Pankaj Walecha
PUB. DATE
January 2010
SOURCE
International Orthopaedics;Jan2010, Vol. 34 Issue 1, p125
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract  The sliding compression device, a widely used implant in unstable proximal femoral fractures, suffers from two major limitations: excessive collapse and screw cut-out. Commonly attributed reasons for these are lateral wall comminution and single-point fixation, respectively. We report our experience of stabilising 74 unstable trochanteric fractures, of which 46 cases underwent lateral wall reconstruction using a trochanteric stabilising plate (TSP) in combination with a dynamic hip screw (DHS), and 34 cases with an intact lateral wall had a DHS with an additional anti-rotation screw providing two-point fixation. Fracture consolidation was observed in all cases at an average of 13.56 weeks. Overall functional hip score as per the Salvati and Wilson scoring system was >30 points in 55 patients. Lateral wall reconstruction is an important component in stabilisation of unstable trochanteric fractures and a combination of TSP with a DHS appears to be a useful device to achieve this. Addition of an antirotation screw is likely to enhance the stability further by providing two-point fixation.
ACCESSION #
47380020

 

Related Articles

  • Crutches in Cushing's disease. Davies, M. B.; Scott, I. R.; Babu, V. V. Suresh // Journal of the Royal Society of Medicine;Jul2001, Vol. 94 Issue 7, p348 

    The article discusses the medical case of a 25-year-old woman who reported pain in her shoulder after using crutches for six months. Before using crutches, the woman was diagnosed with hip fracture and was treated with dynamic hip screw and plate fixation. The pain had been present at the time...

  • The effect of moment arm length on high angled femoral neck fractures (Pauwels' III). LePine, Matthew S.; Barfield, William R.; DesJardins, John D.; Hartsock, Langdon A. // Journal of Biomedical Science & Engineering;May2010, Vol. 3 Issue 5, p448 

    This study investigated loads among five fixation types (FT) [three cannulated screws (CS), dynamic hip screws with and without derotational screws (DHS-DS and DHS), and dynamic helical hip screws with and without derotational screws (DHHS-DS and DHHS)] across three fracture moment lengths (ML)...

  • Integrity of the Lateral Femoral Wall in Intertrochanteric Hip Fractures: An Important Predictor of a Reoperation. Palm, Henrik; Jacobsen, Steffen; Sonne-Holm, Stig; Gebuhr, Peter // Journal of Bone & Joint Surgery, American Volume;Mar2007, Vol. 89-A Issue 3, p470 

    Background: Reoperations after intertrochanteric fractures are often necessitated by fracture displacement following mobilization of the patient. The biomechanical complexity of the fracture, the position of the implant, and the patient's characteristics are known to influence postoperative...

  • Comment on: "Outcome of short proximal femoral nail antirotation and dynamic hip screw for fixation of unstable trochanteric fractures. A randomised prospective comparative trial". Fang-Jie Zhang; Guang-Hua Lei // Hip International;Apr-Jun2012, Vol. 22 Issue 2, p234 

    A letter to the editor is presented in response to the article "Outcome of Short Proximal Femoral Nail Antirotation and Dynamic Hip Screw for Fixation of Unstable Trochanteric Fractures. A Randomised Prospective Comparative Trial” by Garg et al., which appeared in a 2011 issue.

  • Use of the Schanz screw as a joystick and the Poller screw in intramedullary nailing for subtrochanteric or proximal femoral fracture. Chen, Chun-Yu; Lin, Kai-Cheng; Yang, Shan-Wei; Tarng, Yih-Wen; Hsu, Chien-Jen; Renn, Jenn-Huei // European Journal of Orthopaedic Surgery & Traumatology;Feb2013, Vol. 23 Issue 2, p241 

    A letter to the editor is presented in response to the article "Use of Blocking Screws in Intramedullary Fixation of Subtrochanteric Fractures’’ by N. Amin et al.

  • Low Incidence of Anti-Osteoporosis Treatment After Hip Fracture. Rabenda, Véronique; Vanoverloop, Johan; Fabri, Valérie; Mertens, Raf; Sumkay, François; Vannecke, Carine; Deswaef, André; Verpooten, Gert A.; Reginster, Jean-Yves // Journal of Bone & Joint Surgery, American Volume;Oct2008, Vol. 90-A Issue 10, p2142 

    Background: Following hip fracture, pharmacologic treatment can reduce the rate of subsequent fragility fractures. The objective of the present study was to assess the proportion of patients who are managed with bisphosphonates or selective estrogen-receptor modulators after hip fracture and to...

  • Distal unlocked proximal femoral intramedullary nailing for intertrochanteric femur fractures. Ozkan, Korhan; Unay, Koray; Demircay, Can; Cakir, Mustafa; Eceviz, Engin // International Orthopaedics;Oct2009, Vol. 33 Issue 5, p1397 

    We investigated whether a proximal femoral nail (PFN) having two lag screws can be implanted without distal locking screws in AO/OTA 31-A1 and 31-A2 intertrochanteric femur fractures. Twenty-four patients with AO/OTA 31-A1 and 31-A2 fractures were treated with a PFN without distal interlocking...

  • Accuracy and awareness of lag screw placement when using the dynamic hip screw for fracture fixation. Matharu, Gulraj S; Shahid, Mohammad; Pynsent, Paul B; Rowlands, Tom // Trauma;Jan2015, Vol. 17 Issue 1, p39 

    The article offers information on a study aimed at determining the accuracy and awareness of lag screw placement while using dynamic hip screw for fracture fixation. Accuracy of lag screw placement was found by using the final intra-operative fluoroscopy images stored in the electronic picture...

  • Individual headless compression screws fixed with three-dimensional image processing technology improves fusion rates of isolated talonavicular arthrodesis. Mei-ming Xie; Kang Xia; Hong-xin Zhang; Hong-hui Cao; Zhi-jin Yang; Hai-feng Cui; Shang Gao; Kang-lai Tang // Journal of Orthopaedic Surgery & Research;1/23/2017, Vol. 12, p1 

    Background: Screw fixation is a typical technique for isolated talonavicular arthrodesis (TNA), however, no consensus has been reached on how to select most suitable inserted position and direction. The study aimed to present a new fixation technique and to evaluate the clinical outcome of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics