TITLE

Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty

AUTHOR(S)
Jiri Gallo; Vitezslav Havranek; Jana Zapletalova
PUB. DATE
January 2010
SOURCE
International Orthopaedics;Jan2010, Vol. 34 Issue 1, p19
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract  We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression analysis. Factors associated with an increased/decreased wear rate included position of the cup relative to Kohler’s line, increase in abduction angle of the cup, traumatic and inflammatory arthritis as a primary diagnosis, and patient height. Severe acetabular bone defects were predicted by an increased wear rate (odds ratio, OR = 5.782 for wear rate above 200 mm3/y), and increased height of the patient (OR = 0.905 per each centimetre). Predictors of severe bone defects in the femur were the increased wear rate (OR = 3.479 for wear rate above 200 mm3/y) and placement of the cup outside of the true acetabulum (OR = 3.292). Variables related to surgical technique were the most predictive of polyethylene wear rate.
ACCESSION #
47380014

 

Related Articles

  • Development and problems of metal-on-metal hip arthroplasty. Shetty, V. D.; Villar, R. N. // Proceedings of the Institution of Mechanical Engineers -- Part H;Feb2006, Vol. 220 Issue 2, p371 

    For over 40 years, the metal-on-polyethylene bearing has dominated the field of total hip replacement. Problems of wear, osteolysis (dissolution of bone), and ultimately failure of prostheses have led to the development of alternative bearing surfaces. Metal-on-metal hip resurfacing has taken...

  • The 2012 John Charnley Award: Clinical Multicenter Studies of the Wear Performance of Highly Crosslinked Remelted Polyethylene in THA. Bragdon, Charles; Doerner, Michael; Martell, John; Jarrett, Bryan; Palm, Henrik; Malchau, Henrik // Clinical Orthopaedics & Related Research;Feb2013, Vol. 471 Issue 2, p393 

    Background: Highly crosslinked polyethylene (HXLPE) in THA was developed to reduce particle-induced periprosthetic osteolysis. A series of clinical studies were initiated to determine the clinical efficacy as judged by patient-reported scores, radiographic osteolysis, and wear analysis of one...

  • Two-year follow-up of revision total hip arthroplasty using a ceramic revision head with a retained wellfixed femoral component: a case series. Ganzer, Dirk; Forke, Lutz; Irlenbusch, Ulrich // Journal of Medical Case Reports;2014, Vol. 8 Issue 1, p325 

    Introduction It is known that a well-fixed stem can be left in situ when only the acetabular component and femoral head have to be changed. However, in a revision case, the use of a ceramic head on an existing taper is not recommended. Slight damages of the taper may increase the risk of a...

  • Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses. Yan, Y.; Neville, A.; Dowson, D,; Williams, S.; Fisher, J. // Proceedings of the Institution of Mechanical Engineers -- Part J;May2008, Vol. 222 Issue 3, p483 

    Osteolysis induced by polyethylene wear debris from metal-on-polyethylene total joint replacements is one of the major reasons for the renewed interest in metal-on-metal (MoM) bearings for total hip arthroplasty. However, long-term clinical performance is as yet unknown for the second generation...

  • POOR SURVIVAL OF ABG I HIP PROSTHESIS IN YOUNGER PATIENTS. Gallo, Jiri; Langova, Katerina; Havranek, Vitezslav; Cechova, Ivana // Biomedical Papers of the Medical Faculty of Palacky University i;2008, Vol. 152 Issue 1, p163 

    Background: Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than two decades. However, the majority of studies have reported only intermediate term outcomes that are not reliable for predicting long-term behavior in all implants. The aim of this study was to...

  • Schmerzhafte Hüftendoprothetik. Hoberg, M.; Holzapfel, B. M.; Rudert, M. // Der Orthopäde;Jun2011, Vol. 40 Issue 6, p474 

    The number of implantations of hip prostheses in Germany is now approximately 190,000 per year. By improving the implants and the development of modern surgical techniques and instruments the revision rate has been significantly reduced. The survival rate of the implants could be further...

  • Risk of Complication and Revision Total Hip Arthroplasty Among Medicare Patients with Different Bearing Surfaces. Bozic, Kevin; Ong, Kevin; Lau, Edmund; Kurtz, Steven; Vail, Thomas; Rubash, Harry; Berry, Daniel // Clinical Orthopaedics & Related Research;Sep2010, Vol. 468 Issue 9, p2357 

    To address the long-term problems of bearing surface wear and osteolysis associated with conventional metal-polyethylene (M-PE) total hip arthroplasty (THA), metal-metal (M-M), and ceramic-ceramic (C-C) bearings have been introduced. These bearing surfaces are associated with unique risks and...

  • Polyethylene and metal wear particles: characteristics and biological effects. Catelas, Isabelle; Wimmer, Markus A.; Utzschneider, Sandra // Seminars in Immunopathology;Sep2011, Vol. 33 Issue 3, p257 

    This paper first presents a brief overview about the mechanism of wear particle formation as well as wear particle characteristics in metal-on-polyethylene and metal-on-metal artificial hip joints. The biological effects of such particles are then described, focusing on the inflammatory response...

  • A 12-station anatomic hip joint simulator. Saikko, V. // Proceedings of the Institution of Mechanical Engineers -- Part H;Nov2005, Vol. 219 Issue 6, p437 

    A novel 12-station hip joint simulator with an anatomic position of the prosthesis was designed and built. The motion of the simulator consists of flexion-extension and abduction-adduction. The load is of the double-peak type. The validation test was done with three similar 28 mm...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics