TITLE

Analysis of the high-frequency response of atomic force microscope cantilevers

AUTHOR(S)
Rabe, U.; Turner, J.; Arnold, W.
PUB. DATE
June 1998
SOURCE
Applied Physics A: Materials Science & Processing;1998, Vol. 66 Issue 7, pS277
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract. In most commercial atomic force microscopes, dynamic modes are now available as standard operation modes. Acoustical vibrations of atomic force microscope cantilevers can be excited either by insonification of the sample or by vibration of the clamped cantilever end. The resulting dynamical system is complex and highly nonlinear. Simplification of this problem is often realized by modeling the cantilever as a one-degree-of-freedom system such that the higher-order flexural modes are neglected. This point-mass model has been successful in advancing material property measurement techniques. The limits and validity of such an approximation have not been fully addressed. In this paper, the flexural beam equation is examined and compared with the point-mass model by using analytical and finite difference numerical techniques. The two systems are shown to have differences in drive-point impedance and are influenced differently by the surface damping and the contact stiffness. The angular deflection at the end of the beam and the influence of lateral sensor tip motion are considered. It is shown that the higher modes must be included for excitations above the first resonance if both the low- and the high-frequency dynamics are to be modeled accurately.
ACCESSION #
4733635

 

Related Articles

  • The role of adhesion in tapping-mode atomic force microscopy. Sarid, D.; Hunt, J.P.; Workman, R.K.; Yao, X.; Peterson, C.A. // Applied Physics A: Materials Science & Processing;1998, Vol. 66 Issue 7, pS283 

    Abstract. The equation of motion of the cantilever of an atomic force microscope (AFM) operating in the tapping mode in the presence of tip-sample adhesion modeled by the JKR theory is solved self-consistently. The vibration of the cantilever is discussed in terms of the parameters...

  • Effect of Contact Position and Tip Properties on the Flexural Vibration Responses of Atomic Force Microscope Cantilevers. Abbasi, M.; Mohammadi, A. Karami // International Review of Mechanical Engineering;Mar2009, Vol. 3 Issue 2, p196 

    The characteristic equation of the flexural vibration of an AFM cantilever with different contact position is derived. Because the tip is not exactly located at one end of the cantilever, the cantilever is modeled as two beams. The effects of tip length, effective mass, contact position and...

  • Nonlinear vibration of rectangular atomic force microscope cantilevers by considering the Hertzian contact theory. Sadeghi, Ali; Zohoor, Hassan // Canadian Journal of Physics;May2010, Vol. 88 Issue 5, p333 

    The nonlinear flexural vibration for a rectangular atomic force microscope cantilever is investigated by using Timoshenko beam theory. In this paper, the normal and tangential tip-sample interaction forces are found from a Hertzian contact model and the effects of the contact position, normal...

  • Dynamic atomic force microscopy operation based on high flexure modes of the cantilever. Girard, P.; Ramonda, M.; Arinero, R. // Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p096105 

    We show the interest of the high flexure modes of vibration for amplitude-controlled atomic force microscopy (AFM). In connection with AFM working conditions, we define the stabilization time threshold of the oscillating sensor. We show experimentally that, in both air and vacuum, the...

  • Optimization and calibration of atomic force microscopy sensitivity in terms of tip-sample interactions in high-order dynamic atomic force microscopy. Liu, Yu; Guo, Qiuquan; Nie, Heng-Yong; Lau, W. M.; Yang, Jun // Journal of Applied Physics;Dec2009, Vol. 106 Issue 12, p124507-1 

    The mechanism of dynamic force modes has been successfully applied to many atomic force microscopy (AFM) applications, such as tapping mode and phase imaging. The high-order flexural vibration modes are recent advancement of AFM dynamic force modes. AFM optical lever detection sensitivity plays...

  • Hydrodynamics of oscillating atomic force microscopy cantilevers in viscous fluids. Maali, Abdelhamid; Hurth, Cedric; Boisgard, Rodolphe; Jai, Cédric; Cohen-Bouhacina, Touria; Aimé, Jean-Pierre // Journal of Applied Physics;4/1/2005, Vol. 97 Issue 7, p074907 

    We present a study of thermal noise of commercially available atomic force microscopy (AFM) cantilevers in air and in water. The purpose of this work is to investigate the oscillation behavior of a clamped AFM microlever in liquids. Up to eight vibration modes are recorded. The experimental...

  • Parametric effects in nanobeams and AFM. Claeyssen, J. C. R.; Tonetto, L.; Carvalho, J. B.; Copetti, R. D. // AIP Conference Proceedings;2014, Vol. 1637, p210 

    Vibration dynamics of forced cantilever beams that are used in nanotechnology such as atomic force microscope modeling and carbon nanotubes is considered in terms of a fundamental response within a matrix framework. The modeling equations are written as a matrix differential equation subject to...

  • Improving the signal-to-noise ratio of high-speed contact mode atomic force microscopy. Payton, O. D.; Picco, L.; Miles, M. J.; Homer, M. E.; Champneys, A. R. // Review of Scientific Instruments;Aug2012, Vol. 83 Issue 8, p083710 

    During high-speed contact mode atomic force microscopy, higher eigenmode flexural oscillations of the cantilever have been identified as the main source of noise in the resultant topography images. We show that by selectively filtering out the frequencies corresponding to these oscillations in...

  • Sensitivity of higher mode of rectangular atomic force microscope to surface stiffness in air environment. Damircheli, M.; Korayem, M. H. // Micro & Nano Letters;2013, Vol. 8 Issue 12, p877 

    The sensitivity of the resonance frequencies and the amplitudes of the first four flexural vibration modes of atomic force microscopy with a rectangular cross-section cantilever in an air environment to variation of a sample's stiffness have been analysed. The cantilever has been modelled using...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics