TITLE

Frequency-agile terahertz-wave parametric oscillator in a ring-cavity configuration

AUTHOR(S)
Minamide, Hiroaki; Ikari, Tomofumi; Ito, Hiromasa
PUB. DATE
December 2009
SOURCE
Review of Scientific Instruments;Dec2009, Vol. 80 Issue 12, p123104
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We demonstrate a frequency-agile terahertz wave parametric oscillator (TPO) in a ring-cavity configuration (ring-TPO). The TPO consists of three mirrors and a MgO:LiNbO3 crystal under noncollinear phase-matching conditions. A novel, fast frequency-tuning method was realized by controlling a mirror of the three-mirror ring cavity. The wide tuning range between 0.93 and 2.7 THz was accomplished. For first demonstration using the ring-TPO, terahertz spectroscopy was performed as the verification of the frequency-agile performance, measuring the transmission spectrum of the monosaccharide glucose. The spectrum was obtained within about 8 s in good comparison to those of Fourier transform infrared spectrometer.
ACCESSION #
47244401

 

Related Articles

  • Phase-sensitive terahertz spectroscopy with backward-wave oscillators in reflection mode. Pronin, A. V.; Goncharov, Yu. G.; Fischer, T.; Wosnitza, J. // Review of Scientific Instruments;Dec2009, Vol. 80 Issue 12, p123904 

    In this article we describe a method which allows accurate measurements of the complex reflection coefficient r⁁=|r⁁|·exp(iφR) of a solid at frequencies of 1–50 cm-1 (30 GHz–1.5 THz). Backward-wave oscillators are used as sources for monochromatic coherent...

  • Evaluation of the sensitivity to mechanical vibrations of an IR Fourier spectrometer. Comolli, L.; Saggin, B. // Review of Scientific Instruments;Dec2005, Vol. 76 Issue 12, p123112 

    This article presents an experimental and theoretical investigation of the sensitivity to mechanical disturbances of a Fourier-transform infrared spectrometer, the Planetary Fourier Spectrometer, currently orbiting around Mars onboard ESA Mars Express orbiter. A theoretical analysis has been...

  • Modulated photoluminescence spectroscopy with a step-scan Fourier transform infrared spectrometer. Shao, Jun; Lu, Wei; Lü, Xiang; Yue, Fangyu; Li, Zhifeng; Guo, Shaoling; Chu, Junhao // Review of Scientific Instruments;Jun2006, Vol. 77 Issue 6, p063104 

    Fourier transform infrared (FTIR) spectrometer is a powerful tool for studying the photoluminescence (PL) properties of semiconductors, due to its well-known multiplexing and throughput advantages. However, it suffers from internal He–Ne laser disturbance in near-infrared and/or...

  • Order received for commercial GC/FTMS.  // LC-GC Europe;May2006, Vol. 19 Issue 5, p10 

    The article reports that Varian Inc. has received an order for its gas chromatogram (GC)/ Fourier transform mass spectrometer (FTMS). The system incorporates a Varian GC with a high performance FTMS that would provide researchers in environmental laboratories with optimum structural elucidation...

  • Fourier Transform Infrared (FT-IR) Spectrometry. Sherma, Joseph; Larkin, John D.; Larkin, Frances H. // Journal of AOAC International;Jul/Aug2004, Vol. 87 Issue 4, p113A 

    Presents a field guide to Fourier Transform Infrared (FT-IR)-based spectrometry instrumentation. Description of the principle operation of FT-IR instruments to obtain a spectrum for analysis; Shift from radiation dispersion to interferometry and a processing circuit to perform Fourier analysis;...

  • Technique for measuring the groove density of a diffraction grating with elimination of the eccentricity effect. Jun Lim, Takao; Seungyu Rah, Takao // Review of Scientific Instruments;Mar2004, Vol. 75 Issue 3, p780 

    For absolute measurement of groove density of diffraction gratings, we suggest a simple method that utilizes two parallel beams, a rotary beam splitter and single-beam long trace profiler. We use the fact that two parallel beams are focused on a point in the focal plane of a Fourier transform...

  • Pressure jump relaxation setup with IR detection and millisecond time resolution. Schiewek, Martin; Krumova, Marina; Hempel, Günter; Blume, Alfred // Review of Scientific Instruments;Apr2007, Vol. 78 Issue 4, p043101 

    An instrument is described that allows the use of Fourier transform infrared (FTIR) spectroscopy as a detection system for kinetic processes after a pressure jump of up to 100 bars. The pressure is generated using a high performance liquid chromatography (HPLC) pump and water as a pressure...

  • Preparation of ultrathin free-standing targets for (e,2e) spectroscopy. Fang, Z.; Guo, X.; Utteridge, S.; Canney, S.A.; McCarthy, I.E; Vos, M.; Weigold, E. // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4396 

    Describes the procedures used for the preparation of ultrathin free-standing membranes for spectroscopy. Importance of the development of radio frequency plasma source; Importance of a conducting sublayer in avoiding charging problem; description of a well prepared target.

  • Absolute spectral sensitivity of linear-photodiode arrays in 7–20 keV energy x-ray range. Dolbnya, I. P.; Kurylo, S. G. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p677 

    This paper deals with the study of the absolute spectral sensitivity of linear photodiode arrays (of LF1024-25/2 type) as x-ray one-coordinate detectors within the 7-20 keV energy range. The threshold sensitivity of such detectors was estimated in the indicated range. The measurements were made...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.