An automatic classification technique for attenuation correction in positron emission tomography

AUTHOR(S)
Bettinardi, V.; Pagani, E.; Gilardi, M. C.; Landoni, C.; Riddell, C.; Rizzo, G.; Castiglioni, I.; Belluzzo, D.; Lucignani, G.; Schubert, S.; Fazio, F.
PUB. DATE
May 1999
SOURCE
European Journal of Nuclear Medicine;1999, Vol. 26 Issue 5, p447
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract. In this paper a clustering technique is proposed for attenuation correction (AC) in positron emission tomography (PET). The method is unsupervised and adaptive with respect to counting statistics in the transmission (TR) images. The technique allows the classification of pre- or post-injection TR images into main tissue components in terms of attenuation coefficients. The classified TR images are then forward projected to generate new TR sinograms to be used for AC in the reconstruction of the corresponding emission (EM) data. The technique has been tested on phantoms and clinical data of brain, heart and whole-body PET studies. The method allows: (a) reduction of noise propagation from TR into EM images, (b) reduction of TR scanning to a few minutes (3 min) with maintenance of the quantitative accuracy (within 6%) of longer acquisition scans (15-20 min), (c) reduction of the radiation dose to the patient, (d) performance of quantitative whole-body studies.
ACCESSION #
4721212

 

Related Articles

  • Cardiac single-photon emission tomography: is attenuation correction enough? Hutton, Brian F. // European Journal of Nuclear Medicine;1997, Vol. 24 Issue 7, p713 

    Consider the possible solutions to improve cardiac single-photon emission tomography. Application of attenuation correction to reduce the uncertainty of the procedure; Compensation for the distance-dependent resolution; Reasons for the reduced perfusion of the procedure.

  • PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Burger, C.; Goerres, G.; Schoenes, S.; Buck, A.; Lonn, R.; von Schulthess, K. // European Journal of Nuclear Medicine & Molecular Imaging;2002, Vol. 29 Issue 7, p922 

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation...

  • Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [[sup 18] F]FDG PET. Visvikis, D.; Cheze-LeRest, C.; Costa, D. C.; Bomanji, J.; Gacinovic, S.; Ell, P. J. // European Journal of Nuclear Medicine;2001, Vol. 28 Issue 9, p1326 

    Standardised Uptake Values (SUVs) are widely used in positron emission tomography (PET) as a semi-quantitative index of fluorine-18 labelled fluorodeoxyglucose uptake. The objective of this study was to investigate any bias introduced in the calculation of SUVs as a result of employing ordered...

  • Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study. Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D'Aragona Tagliavia, Irene; Casagranda, Mirta; Cannizzaro, Giorgio; Giubbini, Raffaele; Bertagna, Francesco; Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina; Bertolaccini, Pietro; Bonini, Rita; Marzullo, Paolo // European Journal of Nuclear Medicine & Molecular Imaging;Oct2011, Vol. 38 Issue 10, p1890 

    Purpose: In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of...

  • Positron emission tomography/computed tomography–imaging protocols, artifacts, and pitfalls Bockisch, Andreas; Beyer, Thomas; Antoch, Gerald; Freudenberg, Lutz S.; Kühl, Hilmar; Debatin, Jörg F.; Müller, Stefan P. // Molecular Imaging & Biology;Jul2004, Vol. 6 Issue 4, p188 

    There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in...

  • Parameterization of the Mie Extinction and Absorption coefficients for water clouds.  // Journal of the Atmospheric Sciences;5/1/2000, Vol. 57 Issue 9, p1311 

    Presents information on a study which addressed the parameterization of the Mie extinction and absorption coefficients for water clouds. Parameterization of absorption efficiency; Methodology of the study; Results and discussion.

  • Towards a voltage tunable two-color quantum-well infrared photodetector. Majumdar, Amlan; Choi, K. K.; Rokhinson, L. P.; Tsui, D. C. // Applied Physics Letters;1/28/2002, Vol. 80 Issue 4, p538 

    Two-color quantum-well infrared photodetectors (QWIPs), based on electron transfer between coupled QWs, suffer from the presence of the shorter wavelength peak at all bias voltages V[sub b]. We investigate this problem by studying the bias dependence of absorption coefficient α and...

  • Ultrasonic Attenuation as Influenced by Elongated Grains. Ahmed, S.; Thompson, R. B.; Panetta, P. D. // AIP Conference Proceedings;2003, Vol. 657 Issue 1, p109 

    Reliable nondestructive evaluation of structural/machine components fabricated from polycrystalline materials require the knowledge of attenuation and dispersion of an ultrasonic wave propagating through such microscopically inhomogeneous medium. Expected propagation characteristics of...

  • Absorption of coefficient of 4H silicon carbide from 3900 to 3250... Sridhara, S.G.; Devaty, R.P.; Choyke, W.J. // Journal of Applied Physics;9/1/1998, Vol. 84 Issue 5, p2963 

    Focuses on the absorption coefficient of four hydrogen silicon carbide at room temperature. Range of the wave lengths; Correlation of the shift in the band gap with the temperature; Presentation of an estimate of thew absorption coefficient of 4hydrogen silicon carbide at two degrees kelvin.

  • Radiography of nonaxisymmetric objects: An onion-peeling inversion method. Schwierz-Iosefzon, T.; Notea, A.; Deutsch, M. // Applied Physics Letters;9/9/2002, Vol. 81 Issue 11, p2121 

    An onion-peeling method for obtaining the linear attenuation coefficient distribution within a body from a single radiographic projection is presented. Unlike previous methods, which are applicable only to axi- or centrosymmetric objects, ours requires only mirror symmetry relative to the plane...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics