TITLE

Status of the new multipoint, multipulse Thomson scattering diagnostic for the MST RFP (abstract)

AUTHOR(S)
Den Hartog, D. J.; Andrew, P. L.; Holly, D. J.
PUB. DATE
January 2001
SOURCE
Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1133
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We are building a new Thomson scattering diagnostic system to measure electron temperature and density on the Madison Symmetric Torus (MST) reversed-field pinch experiment. This system has been designed to produce accurate single-shot measurements for 10 eV=10[sup 18] m[sup -3]. Scattered light will be simultaneously recorded from 20 radial locations across the 50 cm minor radius of the plasma. Multipulse capability will be provided by two identical Nd:YAG pulsed lasers whose trigger timing can be independently varied. This will allow several combinations of input energy and pulse timing during an MST discharge, ranging from one 4 J pulse for increased accuracy during low density operation to 1 J pulses at 100 Hz for temporal evolution measurements. Scattered light will be collected by a custom deep-focus lens and coupled by optical fiber to 20 identical filter polychromators. These polychromators are being manufactured by General Atomics and use silicon avalanche photodiode detectors. Each polychromator contains three wavelength channels to allow determination of T[sub e], plus one channel at the laser wavelength to allow calibration using Rayleigh scattering for measurement of n[sub e]. System control and data acquisition will be done with dedicated personal computers. © 2001 American Institute of Physics.
ACCESSION #
4716990

 

Related Articles

  • The new RFX Thomson scattering system. Pasqualotto, R.; Nielsen, P.; Giudicotti, L. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1134 

    The present Thomson scattering system at the reversed field experiment routinely determines electron temperature and density profiles in various modes of operation but only provides a single profile of each discharge. The new system will use a Nd:YLF laser providing measurements every 20 ms. At...

  • High-resolution edge Thomson scattering measurements on the Alcator C-Mod tokamak. Hughes, J. W.; Mossessian, D. A.; Hubbard, A. E.; Marmar, E. S.; Johnson, D.; Simon, D. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1107 

    A high-resolution Thomson scattering diagnostic is in operation on the Alcator C-Mod tokamak, measuring radial profiles of electron temperature and density at the plasma edge. Photons are scattered from a Nd–yttrium–aluminum–garnet laser beam pulsed at 30 Hz (1.3 J, 8 ns...

  • Measurements of the electron temperature by the Thomson scattering system on the Hanbit magnetic mirror device. Lee, H. G.; Lee, S. G.; Kim, B. C.; Hong, J.; Kim, W. C.; Choh, K. K.; Choi, J. H.; Yang, J. G.; Na, H. K.; Doh, C. J.; Hwang, S. M.; Kwon, M.; Won, Y. H. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1118 

    A Thomson scattering system on the Hanbit magnetic mirror device has been installed to measure the electron temperature and density of the plasma in the central cell. The configuration is based on a standard 90° scattering scheme. The optical system consists of a Q-switched Nd:YAG laser,...

  • Upgraded calibrations of the Thomson system at DIII-D. Bray, B.; Hsieh, C.; Carlstrom, T. N.; Makariou, C. C. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1115 

    The DIII-D Thomson system measures electron density (n[sub e]) and temperature (T[sub e]) with eight pulsed ND:YAG lasers along three paths through the plasma vessel. The components of the Thomson system are absolutely calibrated so the measurements can be combined into a single profile from a...

  • Optical measurements for turbulence characterization in RFX-mod edge. Agostini, M.; Scarin, P.; Cavazzana, R.; Fassina, A.; Alfier, A.; Cervaro, V. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D715 

    The edge of the reversed field pinch experiment RFX-mod (R=2 m, a=0.46 m) is characterized by a complex magnetic topology and strong pressure gradients. A set of fast spectroscopic diagnostics has been designed to characterize both main plasma edge parameters and turbulence, including coherent...

  • Active control of laser beam direction for LHD YAG Thomson scattering. Yamada, I.; Narihara, K.; Yamauchi, K.; Hayashi, H. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1126 

    We have developed a YAG Thomson scattering (TS) system for the measurements of electron temperature and density profiles on the large helical device (LHD). The LHD-TS has four YAG lasers, and flexible operational modes are possible by using them. For example, (1) high-energy mode: The pulse...

  • Advances in the CO[sub 2] laser collective Thomson scattering fast ion/alpha particle diagnostic (abstract). Richards, R. K.; Hutchinson, D. P. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1147 

    A collective Thomson scattering diagnostic is being developed for the measurement of confined fast ions in hot, dense plasmas. This includes such measurements as the ion tail in JT-60U and the alphas produced in a burning reactor or the upgraded Joint European Torus device. The diagnostic also...

  • Apparatus for multipoint Thomson scattering measurements in the ETA-BETA II reversed field pinch experiment. Bassan, M.; Buffa, A.; Giudicotti, L. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p1027 

    A multipoint Thomson scattering apparatus under development for the measurement of spatial T[sub e] and n[sub e] profiles in the ETA-BETA II reverse field pinch experiment is described. The apparatus is based upon the two-channel analysis method already adopted in the TFR tokamak. The 90°...

  • Thomson scattering measurements in the RFX reversed field pinch Bassan, M.; Bilato, R.; Giudicotti, L.; Pasqualotto, R.; Sardella, A. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p718 

    Reports on the first systematic measurements of the electron temperature spatial profile in the reversed field pinch experiment RFX using a single pulse Thomson scattering diagnostic. Design of the diagnostic; Electron temperature profiles; Improved detection electronics and profile measurements.

Share

Read the Article

Courtesy of

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics