TITLE

Microwave reflectometry for turbulence studies on ASDEX upgrade (abstract)

AUTHOR(S)
Ribeiro, T. T.; Serra, F.; Manso, M. E.; Vergamota, S.; Cupido, L.; Silva, A.; Conway, G. D.; Ryter, F.; Suttrop, W.
PUB. DATE
January 2001
SOURCE
Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p319
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The reflectometry system installed in the tokamak ASDEX Upgrade has 11 channels primarily aimed at profile measurements and two dedicated channels operating at fixed frequency to study density fluctuations. The channels used for profile measurements can also be operated at fixed frequency. In this article we describe the potential of the system to study important characteristics of the plasma turbulence, from combined fixed frequency and profile measurements (to localize the reflecting layers). The numerical tools used to treat fixed frequency data are briefly described. Using a set of similar discharges and the ability of the microwave reflectometry system to probe simultaneously different layers with several channels, we obtain the time evolution of the integrated power spectra of the different signals versus the minor radius of the plasma. In plasma with H-mode edge and internal transport barrier we could identify a zone at the plasma core and another at the edge with reduced fluctuation levels, coinciding with the increase of central electron temperature and the L–H transition, respectively. Before each barrier is established, the turbulence is observed to decrease at the lower frequency range and is enhanced at the higher frequencies. In modulation electron cyclotron resonance heating experiments similar modifications in turbulence spectra are observed and may be correlated with the modulation period. © 2001 American Institute of Physics.
ACCESSION #
4716909

 

Related Articles

  • Plasma mass density, species mix, and fluctuation diagnostics using a fast Alfven wave. Ikezi, H; deGrassie, J S; Pinsker, R I; Snider, R T // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p478 

    Proposes the use of a fast Alfven wave interferometer and reflectometer as a tokamak diagnostic to measure the plasma mass density, deuterium-tritium species mix profile, and density fluctuations. Phase velocity of the fast wave propagating across the magnetic field; Position of the ion-ion...

  • X-mode heterodyne reflectometer for edge density profile measurements on Tore Supra. Clairet, F.; Sabot, R.; Bottereau, Ch.; Chareau, J. M.; Paume, M.; Heuraux, S.; Colin, M.; Hacquin, S.; Leclert, G. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p340 

    A new broadband reflectometer operating in the frequency range 50–75 GHz in extraordinary mode polarization has been developed and tested on Tore Supra to measure edge density profiles. Using solid state source and active frequency multipliers, it performs routine measurements in 20...

  • Refiectometry on ITER and ITER Joint Central Team and Home Teams Vayakis, G.; Bretz, N.; Doyle, E.; Vershkov, V. A.; Donne, A. J. H.; Irby, J.; Mase, A.; Sanchez, J.; Shevchenko, V. F.; Walker, C. I. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p435 

    Focuses on the use of reflectometry on the International Thermonuclear Experimental Reactor to measure the density profile in the main plasma and the divertor and to provide measurements of the plasma position and shape supplementary to the magnetic diagnostics. Systems required to access the...

  • Development of a fast solid-state high-resolution density profile reflectometer system on the DIII-D tokamak Kim, K. W.; Doyle, E. J.; Rhodes, L.; Peebles, W. A.; Rettig, C. L.; Luhmann, Jr., N. C. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p466 

    Describes the implementation of a highly reliable density profile reflectometer system on the DIII-D tokamak via fast-sweep broadband frequency-modulated reflectometry. Density profile measurements; Signal quality variations with changing frequency sweep rates; Planned improvements to the system.

  • The ten-channel pulsed radar reflectometer at the TEXTOR-94 tokamak. van Gorkom, J. C.; van de Pol, M. J.; Donné, A. J. H. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p336 

    A new ten-channel pulsed radar reflectometer has been taken into operation at the Torus Experiment for Technology Oriented Research-94. The system will be used simultaneously as a density profile and as a density fluctuation diagnostic. Ten density layers from 0.4×10[sup 19] to 4×10[sup...

  • Implementation of reflectometry as a standard density profile diagnostic on DIII-D. Zeng, L.; Doyle, E. J.; Luce, T. C.; Peebles, W. A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p320 

    The profile reflectometer system on the DIII-D tokamak has been significantly upgraded in order to improve time coverage, data quality, and profile availability. The performance of the reflectometer system, which utilizes continuous frequency modulated (FMCW) radar techniques, has been improved...

  • Spatial resolution of microwave/millimeter-wave reflectometry. Baang, S.; Domier, C. W.; Luhmann, N. C.; Peebles, W. A.; Rhodes, T. L. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3013 

    Reflectometry is currently being used to investigate density fluctuations and turbulence in tokamak plasmas. However, there are unresolved questions about the spatial resolution and wave number sensitivity of this diagnostic method which impact the interpretation of the data. These questions are...

  • Current profile studies in ITER via dual-polarization reflectometry (abstract). Pavlichenko, O. S.; Skibenko, A. I. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2907 

    The poloidal field of current in a tokamak influences the propagation of the upper extraordinary EM wave (UXW) in a plasma. Calculations show that in an ITER plasma [B = 4.9 T, 1 = 22 MA, n(0) = 1 × 10[sup 20] m[sup -3]] the current profile changes result in a noticeable shift Δr of the...

  • Simulation of reflectometry density changes using a 2D full-wave code. da Silva, F.; Manso, M.; Silva, A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p311 

    Broadband reflectometry is used to obtain density profiles in fusion plasmas using waves reflected at different plasma layers. The reflected signal can be severely affected by plasma fluctuations and/or fast density changes. In order to understand the plasma response, a finite difference time...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics