TITLE

Electrode sheath voltage in pulsed high-pressure mercury arcs

AUTHOR(S)
Kloss, A.; Schneidenbach, H.; Hess, H.
PUB. DATE
May 2001
SOURCE
Applied Physics Letters;5/14/2001, Vol. 78 Issue 20, p3027
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The electric field strength and the electrode sheath voltage in high-pressure mercury arcs were experimentally determined for operation in a current-pulse mode. The current was sinusoidally alternating with a basic frequency of 50 Hz. Each fifth half cycle was pulsed with different ratios of the maximum current in the pulse to those in the other four half cycles. The experimental results quite well agree with model calculations considering radiation transport. The most impressive feature of the electrode sheath voltage is a very pronounced minimum immediately after the reignition peak which can reach high negative values. © 2001 American Institute of Physics.
ACCESSION #
4710710

 

Related Articles

  • High pressure discharges in cavities formed by microfabrication techniques. Khan, Babar A.; Cammack, David A. // Applied Physics Letters;7/14/1997, Vol. 71 Issue 2, p163 

    Presents the operation of a high pressure mercury discharge in electroded and electrodeless structures formed by micromachining techniques. Fabrication of electrodeless and electroded cavities; Formation of high pressure mercury discharge in electrodeless cavities; Measurement of a broad...

  • Electrode-sheath voltages in high-pressure mercury arcs. Kloss, A.; Schneidenbach, H.; Schopp, H.; Hess, H.; Hitzschke, L.; Schalk, B. // Journal of Applied Physics;8/1/2000, Vol. 88 Issue 3, p1271 

    Studies electrode-sheath voltages as a function of time in high-pressure ac mercury arcs running at different frequencies with sinusoidal wave forms. Use of a one-dimensional model to describe the arc-column properties.

  • Voltammetric studies and assay of the anti-inflammatory drug ketoprofen in pharmaceutical formulation and human plasma at a mercury electrode. Ghoneim, M M; Tawfik, A // Canadian Journal of Chemistry;Aug2003, Vol. 81 Issue 8, p889 

    The electrochemical reduction of the anti-inflammatory drug ketoprofen was studied in a Britton-Robinson (B-R.) buffer series of pH 2�11 using dc-polarography, cyclic voltammetry, and coulometry techniques. The electrode reaction pathway of the drug at the dropping mercury electrode was...

  • Photocurrent in ZnO nanowires grown from Au electrodes. Kihyun Keem; Hyunsuk Kim; Gyu-Tae Kim; Jons Soo Lee; Byungdon Min; Kyoungah Cho; Man-Young Sung; Sangsig Kim // Applied Physics Letters;5/31/2004, Vol. 84 Issue 22, p4376 

    ZnO nanowires were grown between two Au electrodes on an Al2O3-deposited Si wafer. Photoresponse, photoresponse spectrum, and current–voltage (I–V) studies were performed for the investigation into photoconduction mechanism in these nanowires. The photoresponse of the nanowires...

  • VOLTAMMETRY OF AQUEOUS CHLOROAURIC ACID WITH HANGING MERCURY DROP ELECTRODE. Korshunov, Andrey V.; Yosypchuk, Bogdan; Heyrovský, Michael // Collection of Czechoslovak Chemical Communications;2011, Vol. 76 Issue 7, p929 

    In d.c. voltammetry of dilute aqueous chloroauric acid with hanging mercury drop electrode, when potential scanning proceeds from negative to positive values, a prominent maximum of cathodic current appears on the curve near 0 V. The effect is explained as due to catalytic evolution of hydrogen...

  • Mercury(II) Selective Membrane Electrode Based on Calix[2]thieno[2]pyrrole. Abbas, Ismail I. // International Journal of Chemistry;Feb2012, Vol. 4 Issue 1, p23 

    The construction, performance, and applications of mercury(II) ion selective electrode based on calix[2]thieno[2]pyrrole receptor are described. The influences of membrane composition and pH on the potentiometric response of the electrode were investigated. The electrode exhibits Nernstian...

  • Electrodeless high-pressure microwave discharges. Offermanns, Stephan // Journal of Applied Physics;1/1/1990, Vol. 67 Issue 1, p115 

    Describes a cylindrical high-pressure mercury plasma sustained by microwave energy within a cavity applicator by solving Maxwell's equations together with the energy balance equation. Advantages of an electrodeless discharge over conventional systems; Characteristics of the microwave discharge...

  • Determination of mercury in aquatic ecosystems. Temerev, S. V. // Journal of Analytical Chemistry;Mar2008, Vol. 63 Issue 3, p292 

    Small concentrations of mercury are determined by the example of the quantitative recovery of a toxicant from snow water in a segregating system with no organic solvent (water-antipyrine-sulfosalicic acid). The organic component of the system in situ forming as a result of acid-base interactions...

  • Voltammetric methods for the determination and electrode process of nitazoxanide bulk drug industry. Krishnaiah, V.; Reddy, M. Thirupal; Reddy, V. Hanuman; Reddy, D. Sudharsan; Reddy, Y. V. Rami // Journal of Chemical & Pharmaceutical Research;2012, Vol. 4 Issue 7, p3601 

    The voltammetric methods were used for investigating the electrochemical properties and the quantitative analysis of nitazoxanide at the Hanging mercury dropping electrode (HMDE). The experimental conditions were optimised to obtain the best characterized peak in terms of peak height with...

Share