ABSTRACT
Abstract. Various points of the experimental implementation of Fourier-transform spectral interferometry are described. It is shown that deviations from the simple theoretical principle of this technique are induced by the use of a spectrometer followed by a pixellated detector. Potential sources of error are studied and techniques of corrections are demonstrated. Various applications of this technique to the study of spectrometers are discussed.
ACCESSION #
4681078

 

Related Articles

  • Extending a continuous scan Fourier transform spectrometer for time-resolved Fourier transform spectroscopy with <0.5 cm-1 spectral and <10 ns time resolution in the visible region Lindner, Jorg; Stahlhut, Oliver; Wilhelm, Ralf; Ermisch, Karsten // Review of Scientific Instruments;Apr98, Vol. 69 Issue 4, p1629 

    Describes the extension of continuous scan Fourier transform spectrometer (FTS) for time-resolved FTS (TS-FTS). Characteristics of the FTS; Realization of the data acquisition and experimental setup; Examples of time-resolved measurements; Signal-to-noise behavior of TS-FTS.

  • Inversion of time domain signals from a Balle–Flygare type microwave spectrometer. Campbell, Edward J. // Review of Scientific Instruments;Aug1993, Vol. 64 Issue 8, p2166 

    The method of sine and cosine Fourier transforms with a phase correction, well known in NMR and traveling wave Fourier transform microwave spectroscopy, is examined for the pulsed beam Fabry-Perot cavity. The validity of this approach is closely related to the result, noted previously elsewhere...

  • Phase-modulated ellipsometer using a Fourier transform infrared spectrometer for real time applications. Canillas, A.; Pascual, E.; Drévillon, B. // Review of Scientific Instruments;Aug1993, Vol. 64 Issue 8, p2153 

    A new Fourier transform infrared phase-modulated ellipsometer is presented. It combines the high frequency provided by a photoelastic modulator (37 kHz) with the low frequency of the Fourier transform infrared spectroscopy (<1 kHz), by means of a numerical data acquisition system. A full...

  • Researchers demonstrate optics-free pixel array.  // Vision Systems Design;Aug2011, Vol. 16 Issue 8, p6 

    The article reports on the development of Planar Fourier Capture Array (PFCA) chip-scale sensor for far field imaging by researchers at Cornell University in Ithaca, New York.

  • A Fourier transform mass spectrometer for surface analysis by laser-induced thermal desorption of molecular adsorbates. Land, Donald P.; Pettiette-Hall, Claire L.; Sander, Dirk; McIver, Robert T.; Hemminger, John C. // Review of Scientific Instruments;Jun90, Vol. 61 Issue 6, p1674 

    A Fourier transform mass spectrometer (FTMS) for ultrahigh-vacuum surface studies is described. The instrument incorporates standard surface analysis techniques such as Auger electron spectroscopy (AES), low-energy electron diffraction (LEED), and Ar ion sputtering, along with laser-induced...

  • A static Fourier-transform spectrometer based on Wollaston prisms. Padgett, M.J.; Harvey, A.R. // Review of Scientific Instruments;Apr95, Vol. 66 Issue 4, p3807 

    Describes the design of a static Fourier-transform spectrometer based on Wollaston prisms. Principle of operation; Production of an interferogram in the spatial domain; Localization of the interference fringes coincident with the plane of detector; Calculation of the wavelength spectrum.

  • TES -- TECHNOLOGY AND PHYSICS. de Korte, P. // EAS Publications Series;2009, Vol. 37, p19 

    This paper gives an overview of the potential of and developments on Transition Edge Sensors for astronomical research from Space. This type of sensor is under development for imaging X-ray spectrometers as well as for very sensitive InfraRed and sub-mm imaging detectors. This paper describes...

  • An automatic molecular beam microwave Fourier transform spectrometer. Andresen, U.; Dreizler, H.; Grabow, J.-U.; Stahl, W. // Review of Scientific Instruments;Dec1990, Vol. 61 Issue 12, p3694 

    We present hardware and software details of the pulsed molecular beam microwave Fourier transform (MB-MWFT) spectrometer used in the Kiel microwave group. We emphasize an automatic scanning facility which greatly increases the efficiency of MB-MWFT spectroscopy for the measurement of unassigned...

  • Satellite observations and modeling of transport in the upper troposphere through the lower mesosphere during the 2006 major stratospheric sudden warming. Manney, G. L.; Harwood, R. S.; MacKenzie, I. A.; Minschwaner, K.; Allen, D. R.; Santee, M. L.; Walker, K. A.; Hegglin, M. I.; Lambert, A.; Pumphrey, H. C.; Bernath, P. F.; Boone, C. D.; Schwartz, M. J.; Livesey, N. J.; Daffer, W. H.; Fuller, R. A. // Atmospheric Chemistry & Physics;2009, Vol. 9 Issue 14, p4775 

    An unusually strong and prolonged stratospheric sudden warming (SSW) in January 2006 was the first major SSW for which globally distributed long-lived trace gas data are available covering the upper troposphere through the lower mesosphere. We use Aura Microwave Limb Sounder (MLS), Atmospheric...