TITLE

A short pulse (7 μs FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

AUTHOR(S)
Irimia, Daniel; Dobrikov, Dimitar; Kortekaas, Rob; Voet, Han; van den Ende, Daan A.; Groen, Wilhelm A.; Janssen, Maurice H. M.
PUB. DATE
November 2009
SOURCE
Review of Scientific Instruments;Nov2009, Vol. 80 Issue 11, p113303
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 μs have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 μm nozzle releases about 1016 particles/pulse and the beam brightness was estimated to be 4×1022 particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5×10-6 Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow (Δv/v=2%–3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.
ACCESSION #
45515492

 

Related Articles

  • Large atom number Bose-Einstein condensate machines. Streed, Erik W.; Chikkatur, Ananth P.; Gustavson, Todd L.; Boyd, Micah; Torii, Yoshio; Schneble, Dominik; Campbell, Gretchen K.; Pritchard, David E.; Ketterle, Wolfgang // Review of Scientific Instruments;Feb2006, Vol. 77 Issue 2, p023106 

    We describe experimental setups for producing large Bose-Einstein condensates of 23Na and 87Rb. In both, a high-flux thermal atomic beam is decelerated by a Zeeman slower and is then captured and cooled in a magneto-optical trap. The atoms are then transferred into a cloverleaf-style...

  • Absolute density-profile tomography of molecular beams using multiphoton ionization. Schofield, N. E.; Paganin, D. M.; Bishop, A. I. // Review of Scientific Instruments;Dec2009, Vol. 80 Issue 12, p123105 

    We describe an approach for the absolute density measurement of rotationally symmetric molecular beams via multiphoton ionization. This simple single-projection tomographic technique requires only knowledge of the spatial intensity profile and ionization characteristics of the focused laser beam...

  • Construction of a low velocity metastable helium atomic beam. Woestenenk, G. R.; Thomsen, J. W.; van Rijnbach, M.; van der Straten, P.; Niehaus, A. // Review of Scientific Instruments;Oct2001, Vol. 72 Issue 10, p3842 

    We have constructed an atomic beam of metastable helium atoms He(2 [sup 3]S) with a mean velocity of 300 m/s (15 K) and a yield of 3×10[sup 12] atoms/s sr. The metastable atoms are produced in a dc discharge in a cryogenic environment cooled by liquid helium. Using a hexapole magnetic lens,...

  • Pulsed metastable atomic beam source for time-of-flight applications. Kohlhase, A.; Kita, S. // Review of Scientific Instruments;Dec1986, Vol. 57 Issue 12, p2925 

    A metastable atomic beam source was developed utilizing pulsed helium and argon nozzle beams. A coaxial electron gun, which can be used in a pulsed as well as in a continuous mode, excites the noble gases to their metastable states by electron bombardment in the direction of propagation of the...

  • An efficient trap for the collection of a cadmium atomic beam. Bauman, R.P.; Martin, N.L.S. // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p4900 

    Describes precautions for the successful operation of a cross-beam apparatus which uses an atomic cadmium target. Inclusion of a novel type of high-voltage trap for the collection of cadmium vapor; Minimization of the deleterious effects of the cadmium 'background gas' in the apparatus.

  • Simple emittance measurement of H- beams for neutral beam injectors in magnetic fusion. Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T. // Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2534 

    Discusses an emittance meter developed using the pepper-pot method. Use of Kapton foils to detect intensity distributions of small beamlets at the 'image' plane of pepperpot; Measurement of the beams for the neutral beam injector of the large helical device.

  • Heavy beam loading measurements of an rf accelerating cavity under amplitude and phase control. Fortgang, C. M.; Jachim, S. P.; Geisik, C.; Gutscher, W. D.; Natter, E. F.; Niesen, J. B. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3405 

    A technique for measuring both resistive and reactive particle-beam-loading effects on an rf accelerating cavity is described. A high-power, six-port reflectometer is used to measure the complex cavity impedance, both with and without beam, as a function of cavity resonant frequency. Resistive...

  • A probe for real-time images of particle beams and their analyses in a merged-beams apparatus. Forand, J. L.; Timmer, C.; Wahlin, E.; DePaola, B. D.; Dunn, G. H.; Swenson, D. R.; Rinn, K. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3372 

    We have developed a real-time charged particle beam probe which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a...

  • Neutral atomic beam source by a spark-discharge method. Minowa, Tatsuya; Katsuragawa, Hidetsugu; Inamura, Takashi // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3280 

    A spark-discharge method has been successfully applied to the generation of neutral metal atoms. The neutral atomic source developed by the method has advantages in simplicity, low cost, and high intensity. Resonance ionization spectroscopy of the Fe and Al atoms was carried out by using the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics