TITLE

Predisposing Factors for Recurrent Shoulder Dislocation After Arthroscopic Treatment

AUTHOR(S)
Porcellini, Giuseppe; Campi, Fabrizio; Pegreffi, Francesco; Castagna, Alessandro; Paladini, Paolo
PUB. DATE
November 2009
SOURCE
Journal of Bone & Joint Surgery, American Volume;Nov2009, Vol. 91-A Issue 11, p2537
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Arthroscopic repair of anterior dislocation of the shoulder can fail. We hypothesized that patients who are at higher risk for redislocation following repair could be recognized preoperatively on the basis of their clinical history. The purpose of the present study was to identify the risk factors for recurrence in a community-based population of patients with traumatic unidirectional instability that was treated with a single arthroscopic technique. Methods: From January 2000 to December 2003, 625 patients with anterior unidirectional instability were managed with an arthroscopic Bankart technique, and 385 met the criteria for inclusion in the study. Demographic data were collected, and clinical follow-up was performed at three, six, twelve, twenty-four, and thirty-six months. Results: At thirty-six months, thirty-one patients (8.1%) had experienced a redislocation; the rate was 13.3% among patients who were twenty-two years of age and younger and 6.3% among older patients. Age at the time of the first dislocation, male sex, and the time from the first dislocation until surgery were significant risk factors for recurrence (p < 0.05 for all). Conclusions: Patients who are more likely to have a redislocation following arthroscopic repair of an anterior shoulder dislocation can be identified preoperatively on the basis of sex, age, and the time from the first dislocation to surgery. Level of Evidence: Prognostic Level II. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
45351647

 

Related Articles

  • Artroscopía de rodilla sin la utilización de dispositivos para isquemia. Villarreal, José María Busto; Figueroa Cal y Mayor, Francisco; Flores, Carlos Terán; Cadena, Carlos Martín Carlos; Quiñones, Marco Antonio González // Acta Ortopedica Mexicana;may/jun2005, Vol. 19 Issue 3, p109 

    The percentage of adverse effects after the use of ischemia devices in knee arthroscopy is relatively high, likewise absolute contraindications exist for the use of these devices. In an intent of obviating this effects without sacrificing the visualization of the surgical field have appealed to...

  • Arthroscopically Assisted Coronoid Fracture Fixation: A Preliminary Report. Michael Hausman; Raymond Klug; Sheeraz Qureshi; Rachel Goldstein; Bradford Parsons // Clinical Orthopaedics & Related Research;Dec2008, Vol. 466 Issue 12, p3147 

    Abstract  We investigated the feasibility of arthroscopically assisted reduction and fixation of small coronoid fractures and the anterior capsule for treatment of patients with Regan and Morrey Types I and II (O’Driscoll Types I and II) coronoid fractures with...

  • 360° arthroscopic capsular release in patients with adhesive capsulitis of the glenohumeral joint – indication, surgical technique, results. Jerosch, Joerg // Knee Surgery, Sports Traumatology, Arthroscopy;May2001, Vol. 9 Issue 3, p178 

    Adhesive capsulitis of the glenohumeral joint is said to be a self-limiting process. However, in some patients the disease can last much longer than 1 year, which may lead patients to more invasive treatment than merely undergoing physiotherapy. Other patients do not accept this severe...

  • Evaluation of a virtual-reality-based simulator using passive haptic feedback for knee arthroscopy. Fucentese, Sandro; Rahm, Stefan; Wieser, Karl; Spillmann, Jonas; Harders, Matthias; Koch, Peter // Knee Surgery, Sports Traumatology, Arthroscopy;Apr2015, Vol. 23 Issue 4, p1077 

    Purpose: The aim of this work is to determine face validity and construct validity of a new virtual-reality-based simulator for diagnostic and therapeutic knee arthroscopy. Methods: The study tests a novel arthroscopic simulator based on passive haptics. Sixty-eight participants were grouped...

  • Arthroscopy and microfracture technique in the treatment of osteochondritis dissecans of the humeral capitellum: report of three adolescent gymnasts. Bojanić, Ivan; Ivković, Alan; Borić, Igor; Bojanić, Ivan; Ivković, Alan; Borić, Igor // Knee Surgery, Sports Traumatology, Arthroscopy;May2006, Vol. 14 Issue 5, p491 

    The aim of this paper is to report on three cases of symptomatic osteochondritis dissecans of the humeral capitellum in adolescent gymnasts, two females and one male. In all the cases arthroscopic surgery was performed. During arthroscopy, loose osteochondral fragments were removed, the defect...

  • Arthroscopic arthrolysis for the treatment of stiffness after total knee replacement gives moderate improvements in range of motion and functional knee scores.  // Advances in Orthopaedics;Sep2010, Vol. 2 Issue 3, p130 

    In this small study, the authors found that arthroscopic arthrolysis was effective for the treatment of knee stiffness following total knee arthroplasty.

  • Arthroscopic Treatment of Anterior-Inferior Glenohumeral Instability. Gartsman, Gary M.; Roddey, Toni S.; Hammerman, Steven M. // Journal of Bone & Joint Surgery, American Volume;Jul2000, Vol. 82-A Issue 7, p991 

    Background: Previous studies on arthroscopic treatment of anterior-inferior glenohumeral instability have focused on the repair of lesions of the anterior-inferior aspect of the labrum (Bankart lesions) and have demonstrated failure rates of as high as 50 percent. The current investigation...

  • Arthroscopic treatment of symptomatic type D medial plica. Mehmet Asik; Sercan Akpinar; Feyyaz Ciftci; Necip Cesur; Reha Tandogan // International Orthopaedics;Dec2008, Vol. 32 Issue 6, p799 

    Abstract  We aimed to review the results of subtotal arthroscopic resection of symptomatic type D medial plica. We retrospectively evaluated 23 knees with symptomatic type D medial plica in 22 patients without other intra-articular pathology. All patients complained of chronic knee pain...

  • Complications in knee arthroscopy. Reigstad, Ole; Grimsgaard, Christian // Knee Surgery, Sports Traumatology, Arthroscopy;May2006, Vol. 14 Issue 5, p473 

    All simple arthroscopic procedures during 1999 through 2001 performed at Baerum community hospital were retrospectively examined. Procedures were excluded when being part of more complex procedures. A total of 876 procedures performed on 785 patients were left for examination. Complications were...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics