TITLE

Albumin in the pump prime: its effect on postoperative weight gain

AUTHOR(S)
Zarro, D.L.; Palanzo, D.A.; Phillips, T.G.
PUB. DATE
March 2001
SOURCE
Perfusion;Mar2001, Vol. 16 Issue 2, p129
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An investigation was conducted to determine whether adding albumin to the prime of the cardiopulmonary bypass circuit had any effect on postoperative weight gain. Patients undergoing non-emergency myocardial revascularization for coronary artery disease were divided into two groups. Group I (albumin) received 250 ml of 5% human albumin in their pump prime, whereas group II (control) served as controls. The same surgeon, anesthesia technique, perfusion circuit and conduct, and postoperative management were employed for all patients in the study. No statistically significant differences could be found between the groups for any of the variables studied, including fluid intake during surgery and the first 24 h postoperation, urine output, fluid balance and postoperative weight gain. The authors conclude from this investigation that adding 250 ml of 5% human albumin to the pump prime has no effect on postoperative weight gain. The next step could be to examine the effect of using larger amounts of albumin or plasma volume expanders in the pump prime.
ACCESSION #
4524365

 

Related Articles

  • Effects of 2 size classes of intratracheally administered airborne dust particles on primary and secondary specific antibody responses and body weight gain of broilers: A pilot study on the effects of naturally occurring dust. Lai, H. T. L.; Nieuwland, M. G. B.; Aarnink, A. J. A.; Kemp, B.; Parmentier, H. K. // Poultry Science;Mar2012, Vol. 91 Issue 3, p604 

    We studied the effects of a concurrent challenge on slow-growing broilers with 1) airborne particles of 2 sizes: fine dust (smaller than 2.5 microns) and coarse dust (between 2.5 and 10 microns) that were directly collected from a broiler house and 2) lipopolysaccharide on intratracheal...

  • Normothermic perfusion and lung function after cardiopulmonary bypass: effects in pulmonary risk patients. Ranucci, M.; Soro, G.; Frigiola, A.; Menicanti, L.; Ditta, A.; Candido, G.; Tambalo, S. // Perfusion;1997, Vol. 12 Issue 5, p309 

    Fifty patients at risk for postoperative lung dysfunction and undergoing elective coronary revascularization have been randomly assigned to receive normothermic (36?C) perfusion with warm heart protection (NP group) or hypothermic (28?C) perfusion with cold heart protection (HP group). Lung...

  • Effects of flow types in cardiopulmonary bypass on gastric intramucosal pH. Hamulu, A.; Atay, Y.; Yagdi, T.; Discigil, B.; Bakalim, T.; Buket, S.; Bilkay, O. // Perfusion;1998, Vol. 13 Issue 2, p135 

    The aim of this study was to determine the relationship between splanchnic perfusion and oxygen consumption, and flow types in cardiopulmonary bypass (CPB), by measuring gastric intramucosal pH. Twenty patients undergoing elective open-heart surgery were prospectively randomized to receive...

  • A retrospective study on perfusion incidents and safety devices. Mejak, B.L.; Stammers, A.; Rauch, E.; Vang, S.; Viessman, T. // Perfusion;Jan2000, Vol. 15 Issue 1, p51 

    Despite the acceptance of extracorporeal circulation as an effective modality to facilitate cardiac surgery, patient outcomes can be negatively influenced by the occurrence of perfusion incidents. A perfusion survey was conducted to identify safety techniques and incidents related to...

  • The selection of priming fluids for cardiopulmonary bypass in the UK and Ireland. Lilley, Angela // Perfusion;Sep2002, Vol. 17 Issue 5, p315 

    The ideal prime for Cardiopulmonary Bypass (CPB) has never been fully established. The development of acid-base disorders during some routine cases and the possible contribution to this from priming fluids caused this hospital to question its protocol. As a result, we conducted a survey of UK...

  • Lessons from perfusion surveys. Kurusz, M. // Perfusion;1997, Vol. 12 Issue 4, p221 

    Examines surveys on perfusion done in the U.S. since 1977. Comparative data on commonly used devices or techniques that have been promoted to make cardiopulmonary bypass safer; Lessons regarding survey research in general.

  • Techniques of paediatric modified ultrafiltration: 1996 survey results. Darling, E.; Nanry, K.; Shearer, I.; Kaemmer, D.; Lawson, S. // Perfusion;1998, Vol. 13 Issue 2, p93 

    In September 1996, perfusionists from 50 paediatric open-heart surgery programmes were contacted to identify centres that are currently using the technique of modified ultrafiltration (MUF). Of the 50 centres contacted, 22 (44%) were utilizing the technique. These centres were surveyed on the...

  • Sydney Abstracts.  // Perfusion;1998, Vol. 13 Issue 2, p83 

    Presents several research abstracts on cardiovascular perfusion. 'Surface Coatings: Is there a Difference?,' by S.B. Horton, C.A. Thuys, E.B. O'Connor, R.J. Mullaly, W. Butt and T.R. Karl; 'Use of Modified Ultrafiltration in Cardiopulmonary Bypass,' by Kevin Menezes, Ravi Swami, K. Jagannath, K....

  • Effect of surface coating on platelet count drop during cardiopulmonary bypass. Palanzo, D.A.; Zarro, D.L.; Manley, N.J.; Montesano, R.M.; Quinn, M.; Gustafson, P.A. // Perfusion;1999, Vol. 14 Issue 3, p195 

    This study was designed to investigate the effect of surface coating on platelet count drop during cardiopulmonary bypass (CPB). Sixty patients undergoing open-heart surgery were randomly divided into three groups each receiving a different type of coated hollow-fiber membrane oxygenator. The...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics