TITLE

Effect of pressure on electrospray characteristics

AUTHOR(S)
Marginean, Ioan; Page, Jason S.; Kelly, Ryan T.; Tang, Keqi; Smith, Richard D.
PUB. DATE
November 2009
SOURCE
Applied Physics Letters;11/2/2009, Vol. 95 Issue 18, p184103
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An experimental study of pulsating electrosprays operated at subambient pressure is reported. The pressure domain that affords stable electrospray operation appears to be limited by the vapor pressure of the liquid. The voltage driving the electrospray is shown to have a logarithmic dependence on pressure. The observed scaling amends the relationship currently used to calculate the electric field at the tip of the meniscus of an electrified liquid.
ACCESSION #
45036499

 

Related Articles

  • Voltage effects on the volumetric flow rate in cone-jet mode electrospraying. Smith, K. L.; Alexander, M. S.; Stark, J. P. W. // Journal of Applied Physics;3/15/2006, Vol. 99 Issue 6, p064909 

    Electrospray data collected demonstrate the detailed dependence of volumetric flow rate through an electrospray system upon the applied voltage. The sensitivity of nominal flow rate to applied voltage was found to be higher for lower nominal flow rates. For a volumetric flow rate ∼4 nL/s a...

  • Non-coalescence of oppositely charged drops. Ristenpart, W. D.; Bird, J. C.; Belmonte, A.; Dollar, F.; Stone, H. A. // Nature;9/17/2009, Vol. 461 Issue 7262, p377 

    Electric fields induce motion in many fluid systems, including polymer melts, surfactant micelles and colloidal suspensions. Likewise, electric fields can be used to move liquid drops. Electrically induced droplet motion manifests itself in processes as diverse as storm cloud formation,...

  • Electrospray Ionization for Mass Spectrometry.  // LC-GC North America;Feb2012, Vol. 30 Issue 2, p182 

    The article discusses on electrospray ionization (ESI) for mass spectrometry and its processes. It says that the first stage of EIS is the production of charged eluent droplets at the tip of sprayer through using electric field. It mentions that whole solvent desolvation occurs during the...

  • Investigation of electrospray stability with a dynamic liquid flow splitter. Arseniev, A.; Krasnov, N.; Muradymov, M. // Journal of Analytical Chemistry;Dec2014, Vol. 69 Issue 14, p1320 

    The article gives the results of research of electrospray stability with the use of a dynamic splitting of a flow in the spray area under normal conditions. An acidified water-acetonitrile solution (1: 1) was used as an eluant. Experimental results for the used configuration of electrospray...

  • Temperature and structural changes of water clusters in vacuum due to evaporation. Caleman, Carl; van der Spoel, David // Journal of Chemical Physics;10/21/2006, Vol. 125 Issue 15, p154508 

    This paper presents a study on evaporation of pure water clusters. Molecular dynamics simulations between 20 ns and 3 μs of clusters ranging from 125 to 4096 molecules in vacuum were performed. Three different models (SPC, TIP4P, and TIP5P) were used to simulate water, starting at...

  • The micro-discharge family (dark, corona, and glow-discharge) for analytical applications realized by dielectric barriers. Franzke, J. // Analytical & Bioanalytical Chemistry;Oct2009, Vol. 395 Issue 3, p549 

    The similarity principles of electric plasmas, and the current-voltage characteristics of the most prominent kinds of discharges used for analytical applications, are discussed. Most of the discharges can be miniaturized, and some of the analytical applications of different discharges can be...

  • Experiments on single event electrospraying. Stachewicz, Urszula; Dijksman, J. Frits; Yurteri, Caner U.; Marijnissen, Jan C. M. // Applied Physics Letters;12/17/2007, Vol. 91 Issue 25, p254109 

    In order to use electrospraying as an on demand deposition method, well defined and reproducible single electrospraying events have been studied. To generate a single electrospraying event, rectangular voltage pulses superimposed on a constant bias voltage were applied, and optimum settings of...

  • A micropixelated ion-imaging detector for mass resolution enhancement of a QMS instrument. Syed, Sarfaraz; Eijkel, Gert; Maher, Simon; Kistemaker, Piet; Taylor, Stephen; Heeren, Ron // Analytical & Bioanalytical Chemistry;Mar2015, Vol. 407 Issue 8, p2055 

    An in-vacuum position-sensitive micropixelated detector (Timepix) is used to investigate the time-dependent spatial distribution of different charge state (and hence different mass-to-charge ( m/z)) ions exiting an electrospray ionization (ESI)-based quadrupole mass spectrometer (QMS)...

  • Enhanced Sensitivity in Proteomics Analyses Using NanoLC-MS and FAIMS. Venne, Karine; Bonneil, Eric; Eng, Kevin; Thibault, Pierre // PharmaGenomics;May2004, Vol. 4 Issue 4, p30 

    The article discusses about the technique used for the identification of trace-level peptides present in complex protein digests. Two recent ion mobility technologies drift-tube ion mobility spectrometry and high field asymmetric waveform ion mobility mass spectrometry (FAIMS) were introduced as...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics