TITLE

Calorimetric low temperature detectors for low-energetic heavy ions and their application in accelerator mass spectrometry

AUTHOR(S)
Kraft-Bermuth, S.; Andrianov, V. A.; Bleile, A.; Echler, A.; Egelhof, P.; Kiseleva, A.; Kiselev, O.; Meier, H. J.; Meier, J. P.; Shrivastava, A.; Weber, M.; Golser, R.; Kutschera, W.; Priller, A.; Steier, P.; Vockenhuber, C.
PUB. DATE
October 2009
SOURCE
Review of Scientific Instruments;Oct2009, Vol. 80 Issue 10, p103304
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The energy-sensitive detection of heavy ions with calorimetric low temperature detectors was investigated in the energy range of E=0.1–1 MeV/amu, commonly used for accelerator mass spectrometry (AMS). The detectors used consist of sapphire absorbers and superconducting aluminum transition edge thermometers operated at T∼1.5 K. They were irradiated with various ion beams (13C,197Au,238U) provided by the VERA tandem accelerator in Vienna, Austria. The relative energy resolution obtained was ΔE/E=(5–9)×10-3, even for the heaviest ions such as 238U. In addition, no evidence for a pulse height defect was observed. This performance allowed for the first time to apply a calorimetric low temperature detector in an AMS experiment. The aim was to precisely determine the isotope ratio of 236U/238U for several samples of natural uranium, 236U being known as a sensitive monitor for neutron fluxes. Replacing a conventionally used detection system at VERA by the calorimetric detector enabled to substantially reduce background from neighboring isotopes and to increase the detection efficiency. Due to the high sensitivity achieved, a value of 236U/238U=6.1×10-12 could be obtained, representing the smallest 236U/238U ratio measured at the time. In addition, we contributed to establishing an improved material standard of 236U/238U, which can be used as a reference for future AMS measurements.
ACCESSION #
44909746

 

Related Articles

  • The VERA heavy ion program-status and prospects. Golser, R.; Federmann, G.; Kutschera, W.; Priller, A.; Steier, P.; Vockenhuber, C. // AIP Conference Proceedings;2001, Vol. 576 Issue 1, p627 

    Since the start of VERA operation in 1996 the long term goal has been to perform AMS up to the heaviest radionuclides. Last fall a major step forward was made with the installation of movable slits which float up to 13 kV inside the injector bouncer chamber. The injector mass resolution has been...

  • Calorimetric low temperature detectors for mass identification of heavy ions. Kraft, S.; Bleile, A.; Egelhof, P.; Golser, R.; Kisselev, O.; Kutschera, W.; Liechtenstein, V.; Meier, H. J.; Priller, A.; Shrivastava, A.; Steier, P.; Vockenhuber, C.; Weber, M. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p405 

    The energy sensitive detection of heavy ions with calorimetric low temperature detectors (CLTDs) is investigated for the energy range E = 0.1-1 MeV/u, commonly used for accelerator mass spectrometry (AMS). Such measurements complement earlier investigations [1, 2] at higher energies (E = 5-300...

  • Calorimetric low-temperature detectors for high resolution x-ray spectroscopy on stored highly stripped heavy ions. Bleile, A.; Egelhof, P.; Kraft, S.; McCammon, D.; Meier, H. J.; Shrivastava, A.; Stahle, C. K.; Weber, M. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p409 

    The accurate determination of the Lamb shift in heavy hydrogen-like ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields, not accessible otherwise. For the investigation of the Lyman-α transitions in [sup 208]Pb[sup 81+] or [sup 238]U[sup 91+] with...

  • The Multi-Purpose Detector for NICA heavy-Ion Collider at JINR. Rogachevsky, O. // Physics of Atomic Nuclei;May2012, Vol. 75 Issue 5, p598 

    The Multi-Purpose Detector (MPD) is designed to study heavy-ion collisions at the Nuclotron-based heavy Ion Collider fAcility (NICA) at JINR, Dubna. Its main components located inside a superconducting solenoid are a tracking system composed of a silicon microstrip vertex detector followed by a...

  • Measurements of InGaAs metal–semiconductor–metal photodetectors under high-illumination conditions. Aliberti, K.; Wraback, M.; Stead, M.; Newman, P.; Shen, H. // Applied Physics Letters;4/22/2002, Vol. 80 Issue 16, p2848 

    We report on temporal response measurements of InGaAs metal–semiconductor–metal photodetectors (MSM–PDs) under high-illumination conditions. The peak current efficiency of the MSM–PDs decreases as optical pulse energy increases due to space-charge-screening effects....

  • The AMS Measurements and Its Applications in Nuclear Physics at China Institute of Atomic Energy (CIAE). Shan Jiang; Hongtao Shen; Ming He; Xiangdong Ruan; Weimin Wu; Kejun Dong; Guozhu He; Xianggao Wang; Jian Yuan; Wei Wang; Shaoyong Wu // AIP Conference Proceedings;5/12/2010, Vol. 1235 Issue 1, p144 

    Accelerator Mass Spectrometry (AMS), initiated in late 1970s at McMaster university based on the accelerator and detector technique, has long been applied in the studies on archaeology, geology, and cosmology, as a powerful tool for isotope dating. The advantages of AMS in the analysis of rare...

  • Multispectral long-wavelength quantum-well infrared photodetectors. Mitra, P.; Case, F. C.; McCurdy, J. H.; Zaidel, S. A.; Claiborne, L. T. // Applied Physics Letters;5/12/2003, Vol. 82 Issue 19, p3185 

    Multispectral detector arrays for application in the 8-11 μm spectral band have been fabricated from GaAs/AlGaAs multiple quantum-well (MQW) materials. For efficient narrow-band coupling of the infrared radiation, three-dimensional diffractive resonant optical cavities are patterned into the...

  • Recent photon physics results from the ALICE experiment at the LHC. Arbor, Nicolas // EPJ Web of Conferences;2013, Issue 60, p1 

    We present an overview of the photon analysis in pp and Pb-Pb collisions with data taken by the ALICE experiment at the LHC. The ALICE detectors reconstruct photons by using the two electromagnetic calorimeters (photon spectrometer, sampling calorimeter) and central tracking systems for photon...

  • Evolution of the 2-MeV electrostatic energy analyzer for TEXT-Upgrade (abstract). McLaren, P. E.; Hickok, R. L.; Crowley, T. P.; Lewis, J. F.; Schatz, J. G.; Schoch, P. M.; Connor, K. A.; Ouroua, A. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4582 