TITLE

Experimental study of fluid flow and heat transfer from a square prism approaching the wall of a wind tunnel

AUTHOR(S)
Chakrabarty, Dipes; Brahma, Ranajit
PUB. DATE
July 2009
SOURCE
Journal of Engineering Physics & Thermophysics;Jul2009, Vol. 82 Issue 4, p697
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Experimental investigations of fluid flow and heat transfer have been carried out to study the effect of wall proximity due to flow separation around square prisms. Experiments have been carried for Reynolds number equal to 2.6∙104. The results are presented in the form of pressure coefficient, drag coefficient, and Nusselt numbers for various height ratios, blockage ratios, and angles of attack. The pressure coefficient distribution shows positive values on the front face, whereas on the rear face negative values are observed. The drag coefficient decreases with increase in angle of attack as the height ratio decreases, and its maximum value takes place at an angle of about 50°. Both the local and average Nusselt numbers decrease as the height ratio decreases.
ACCESSION #
44841963

 

Related Articles

  • EXPERIMENTAL INVESTIGATIONS OF HEAT TRANSFER ENHANCEMENT FROM DIMPLED SURFACE IN A CHANNEL. Kore, Sandeep S.; Satishchandra V. Joshi; Narayan K.Sane // International Journal of Engineering Science & Technology;2011, Vol. 3 Issue 8, p6277 

    An experimental investigation has been carried out to study heat transfer and friction coefficient by dimpled surface. The aspect ratio of rectangular channel is kept 4:1 and Reynolds number based on hydraulic diameter is varied from 10000 to 40000. The ratios of dimple depth to dimple print...

  • Two‐phase flow convective condensation of refrigerant mixtures under gas/liquid injection. Samuel M. Sami; Joseph D. Comeau // International Journal of Energy Research;Dec2005, Vol. 29 Issue 15, p1355 

    The influence of gas/liquid injection on two‐phase flow condensation heat transfer characteristics of some refrigerant mixtures in horizontal enhanced surface tubing is presented.Correlations were proposed to predict the impact of the gas/liquid injection on the heat transfer...

  • Heat transfer and friction factor enhancement in a square channel having integral inclined discrete ribs on two opposite walls. Chaube, Alok; Gupta, Shailesh; Verma, Prakash // Journal of Mechanical Science & Technology;May2014, Vol. 28 Issue 5, p1927 

    The influence of a gap provided in integral inclined ribs on heat transfer and friction factor enhancement is investigated. Experiments are conducted to obtain heat transfer and friction factor characteristics in a square channel with two opposite in-line ribbed walls for Reynolds numbers from...

  • Heat transfer enhancement in solar air heater with V-shaped perforated baffles. Chamoli, Sunil; Thakur, N. S. // Journal of Renewable & Sustainable Energy;Mar2013, Vol. 5 Issue 2, p023122 

    This experimental study, investigates the heat transfer and friction characteristics in a rectangular duct having its one broad wall heated and roughened with periodic V-down shaped perforated baffles. This work covered a range of Reynolds number (Re) 3800-19 000, open area ratio (β) 12%-44%,...

  • Numerical Flow and Heat Transfer in a Channel with Various Shaped Ribs. Kanoun, M.; Baccar, M.; Mseddi, M. // International Review of Mechanical Engineering;May2008, Vol. 2 Issue 3, p489 

    A numerical investigation of convective heat transfer between a fluid and some physical obstacles (ribs) mounted on the lower wall (12 ribs) and on the upper wall (13 ribs) of a channel was conducted This technique is used in the internal cooling of turbine blades. The governing equations have...

  • Numerical Investigation of Forced Convection Heat Transfer from Square Cylinders in a Channel Covered by Solid wall - Conjugate Situation. Kanna, P. Rajesh; Sivasubramanian, M.; Uthayakumar, M. // FME Transactions;2017, Vol. 45 Issue 1, p16 

    Flow over two isothermal offset square cylinders in a confined channel is simulated for different Reynolds number to reveal the forced convection heat transfer from the heated square cylinders to the ambient fluid for the fixed blockage ratio. The channel is covered by solid walls and conjugate...

  • Performance analysis of W-shaped rib roughened solar air heater. Lanjewar, Atul Manikrao; Bhagoria, Jiwan Lal; Sarviya, Rishindra Mohan // Journal of Renewable & Sustainable Energy;Jul2011, Vol. 3 Issue 4, p043110 

    Artificial rib roughness is a convenient method for enhancing thermal performance of solar air heater. An experimental investigation has been carried out to study the thermo-hydraulic performance of solar air heater using W-shaped ribs on absorber plate, the roughened wall being heated while the...

  • EXPERIMENTAL INVESTIGATION OF FORCED CONVECTIVE HEAT TRANSFER IN RECTANGULAR MICRO-CHANNELS. Kalaivanan, R.; Rathnasamy, R. // Journal of Engineering & Applied Sciences;2010, Vol. 5 Issue 5, p21 

    This paper investigates the experimental program on the study of heat transfer characteristics in micro-channels. The two test sections used are of 47 and 50 micro-channels in rectangular cross-section of equivalent diameters 387 and 327 μm, respectively. Each channel of length 192 mm is...

  • COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES. SELVARAJ, Ponnusamy; SARANGAN, Jagannathan; SURESH, Sivan // Thermal Science;2013, Vol. 17 Issue 4, p1125 

    The article presents computational fluid dynamics studies on heat transfer, pressure drop, friction factor, Nusselt number and thermal hydraulic performance of a plain tube and tube equipped with the three types of internal grooves (circular, square and trapezoidal).Water was used as the working...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library