The use of computed radiography for routine linear accelerator and simulator quality control

AUTHOR(S)
Patel, I.; Natarajan, T.; Hassan, S. S.; Kirby, M. C.
PUB. DATE
October 2009
SOURCE
British Journal of Radiology;Oct2009, Vol. 82 Issue 982, p827
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Computed radiography (CR) systems were originally developed for the purpose of clinical imaging, and there has been much work published on its effectiveness as a film replacement for this end. However, there has been little published on its use for routine linear accelerator and simulator quality control, and therefore we have evaluated the use of the Kodak 2000RT system with large Agfa CR plates as a replacement for film for this function. A prerequisite for any such use is a detailed understanding of the system behaviour, hence characteristics such as spatial uniformity of response, reproducibility of spatial accuracy, plate signal decay with time and the dose-response of plates were investigated. Finally, a comparison of results obtained using CR for the measurement of radiation field dimensions was made against those from radiographic film, and found to be in agreement within 0.1 mm (mean difference for high-resolution images, 0.3 mm root mean square difference) for megavoltage images and 0.3 mm (maximum difference) for simulator images. In conclusion, the CR system has been shown to be a good alternative to radiographic film for routine quality control of linear accelerators and simulators.
ACCESSION #
44768160

 

Related Articles

  • Reduction of Radiation Load in Digital X-Ray Diagnosis. Vladimirov, L.; Vladimirov, Yu.; Kozlov, A. // Biomedical Engineering;Jan2013, Vol. 46 Issue 5, p204 

    The problems of reduction of the transmission coefficient and the aluminum equivalent of objects installed between the patient and the X-ray detector are discussed. Possible approaches to reduction of X-ray dose in digital X-ray diagnosis are suggested.

  • The dynamic range of digital radiographic systeme : dose reduction or risk of overexposure? Berkhout, Wer; Beuger, D. A.; Sanderink, G. C. H.; van der Stelt, P. F. // Dentomaxillofacial Radiology;Jan2004, Vol. 33 Issue 1, p1 

    To investigate the range of diagnostically acceptable digital radiographs and film as a function of exposure time, as well as the relationship to dose reduction and consequences for dental practice. Five systems for intraoral radiography were used to take a series of radiographs, with increasing...

  • Assessment of Patient Doses in CR Examinations Throughout a Large Health Region. Thakur, Yogesh; Bjarnason, Thorarin; Hammerstrom, Kevin; Marchinkow, Lorie; Koch, Tim; Aldrich, John // Journal of Digital Imaging;Feb2012, Vol. 25 Issue 1, p189 

    Optimization and standardization of radiographic procedures in a health region minimizes patient exposure while producing diagnostic images. This report highlights the dose variation in common computed radiography (CR) examinations throughout a large health region. The RadChex cassette was used...

  • Digital mammography more accurate in certain women.  // Contemporary OB/GYN;Nov2005, Vol. 50 Issue 11, p17 

    The article presents the findings of a study which compares the accuracy of digital mammography over conventional film mammography in detecting breast cancer in women as of November 2005. Findings suggest that digital mammography is highly effective for women below 50 years of age, for those who...

  • Excessive Collimation. Sandridge, Thomas G. // Radiologic Technology;Jan/Feb2013, Vol. 84 Issue 3, p305 

    The article reviews book "Excessive collimation" about technical query by Thomas G Sandridge MS, MEd,R.T.(R).

  • GETTING STARTED WITH PROTOCOL FOR QUALITY ASSURANCE OF DIGITAL MAMMOGRAPHY IN THE CLINICAL CENTRE OF MONTENEGRO. Ivanovic, S.; Bosmans, H.; Mijovic, S. // Radiation Protection Dosimetry;2015 Special Issue, Vol. 165, p363 

    The purpose of this work is (i) to work out a test procedure for quality assurance (QA) in digital mammography with newly released test equipment, including the MagicMax mam multimeter (IBA, Germany) and the anthropomorphic tissue equivalent phantom Mammo AT (IBA, Germany), and (ii) to determine...

  • Three-dimensional imaging in periodontal diagnosis -- Utilization of cone beam computed tomography. Mohan, Ranjana; Singh, Archana; Gundappa, Mohan // Journal of Indian Society of Periodontology;Jan-Mar2011, Vol. 15 Issue 1, p11 

    In the field of periodontology and implantology, assessment of the condition of teeth and surrounding alveolar bone depends largely on two-dimensional imaging modalities such as conventional and digital radiography. Though these modalities are very useful and have less radiation exposure, they...

  • Continuing challenges in defining image quality. Shet, Narendra; Chen, Joseph; Siegel, Eliot L. // Pediatric Radiology;May2011, Vol. 41 Issue 5, p582 

    To achieve significant dose reduction without compromising diagnostic efficacy, it is important to understand the effects of exposure reduction on image quality, a concept that is often mentioned but not well defined in the imaging literature. Studies to assess subjective image quality for...

  • EVALUATION OF PATIENT EFFECTIVE DOSES IN CT UROGRAPHY, INTRAVENOUS UROGRAPHY AND RENAL SCINTIGRAPHY. Hamza, Y.; Sulieman, A.; Abuderman, A.; Alzimami, K.; Omer, H. // Radiation Protection Dosimetry;Jul2015, Vol. 165 Issue 1-4, p452 

    Imaging of the renal system is performed with different techniques depending mainly on clinical symptoms and signs. This study intended to evaluate patient effective doses undergoing renal scintigraphy (technetium-99m-diethylene-triamine-pentaacetic acid), computed tomography urography (CTU) and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics