TITLE

Characterization of optical microring ultrasound detector by using a high frequency focused photoacoustic transmitter

AUTHOR(S)
Hyoung Won Baac; Tao Ling; Sheng-Wen Huang; Ashkenazi, Shai; Guo, L. Jay
PUB. DATE
October 2009
SOURCE
Applied Physics Letters;10/5/2009, Vol. 95 Issue 14, p144105
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We characterize a response of optical microring resonator to high frequency focused ultrasound. To properly evaluate the response over high frequency and broadband spectrum, we use a photoacoustic concave transmitter generating and subsequently focusing the ultrasound. A detected focused profile reveals two types of spatial peaks due to the special ring-shaped detector geometry interacting with the high frequency focused ultrasound. Spectral analysis shows that those peaks are contributed by the main and the side lobes of focused ultrasound, respectively. Experimental focal widths agree with theoretical values within ±2 μm error, which can be attributed to the narrow width of waveguide.
ACCESSION #
44539662

 

Related Articles

  • High-speed Intravascular Photoacoustic Imaging of Lipid-laden Atherosclerotic Plaque Enabled by a 2-kHz Barium Nitrite Raman Laser. Pu Wang; Teng Ma; Slipchenko, Mikhail N.; Shanshan Liang; Jie Hui; Shung, K. Kirk; Roy, Sukesh; Sturek, Michael; Qifa Zhou; Zhongping Chen; Ji-Xin Cheng // Scientific Reports;11/7/2014, p1 

    Lipid deposition inside the arterial wall is a key indicator of plaque vulnerability. An intravascular photoacoustic (IVPA) catheter is considered a promising device for quantifying the amount of lipid inside the arterial wall. Thus far, IVPA systems suffered from slow imaging speed (~50 s per...

  • Acoustic mode suppression in an off-axially coupled resonant cell for laser photoacoustic spectroscopy. Nukihara, K.; Izuhara, I.; Sokabe, N. // Review of Scientific Instruments;Jan2003, Vol. 74 Issue 1, p316 

    We report a resonant photoacoustic cell of off-axis coupling type for laser photoacoustic spectroscopy of molecular species at low pressures. Using a waveguide CO[SUB2] laser operating on a 9 μm R (10) line and 4% C[SUB2]H[SUB4]/N[SUB2] standard gas, the time development of the photoacoustic...

  • POSTER PRESENTATION.  // Iranian Journal of Radiology;2009 Supplement, Vol. 6 Issue S1, p105 

    The article presents case studies of various diseases. It highlights various diseases which include retroperitoneal ganglioneuroma, spontaneous intracranial hypotension (SIH) and bronchogenic carcinoma. It states that the diseases were evaluated using various radiological equipments including...

  • Realization of spectrally engineered semiconductor Fabry-Perot lasers with narrow geometrical tolerances. Adolfsson, Göran; Bengtsson, Jörgen; Haglund, Åsa; Nilsson, Bengt; Larsson, Anders // Journal of Applied Physics;May2011, Vol. 109 Issue 9, p093112 

    Spectrally engineered semiconductor Fabry-Perot laser resonators are designed to enhance the optical feedback for selected longitudinal modes, which thereby require less gain for lasing. This is achieved by introducing refractive index perturbations along the length of the resonator. However,...

  • Phase-sensitive detection of signals with non-sinusoidal modulation: The rectangular wave modulation case and its application to the photoacoustic technique. Rojas-Trigos, J. B.; Brindis-López, F. D.; Calderón, A. // Latin-American Journal of Physics Education;Sep2013, Vol. 7 Issue 3, p504 

    The phase-sensitive detection is a powerful mathematical tool in the recovering of signals, at low noise/signal ratio, in many areas of science and engineering. Specifically in Photo thermal Science and Techniques (in all its variants) is essential the implementation of a stage of amplification...

  • Prognosis.  // Current Medical Literature: Cardiology;2006, Vol. 25 Issue 3, p78 

    The article presents several studies related to medical prognosis. One study examined the diagnostic value of adenosine cardiac magnetic resonance in patients who are troponin-negative with coronary artery disease. Another study identified the connection between clinical presentation and plaque...

  • Espondilodiscitis, experiencia en nefrología. Ramírez-Huaranga, Marco A.; de la Nieta-García, M. Dolores Sánchez; Anaya-Fernández, Sara; Arambarri-Segura, Minerva; Caparrós-Tortosa, Guadalupe; Rivera-Hernández, Francisco; Romera-Segorbe, Ana; Vozmediano-Poyatos, M. Carmen; Ferreras-García, Isabel // Nefrologia;2013, Vol. 33 Issue 2, p250 

    Spondylodiscitis is an infection of the vertebral body and adjacent intervertebral discs, whose most common means of spreading is the haematogenous route. It is a rare disease but its overall incidence is increasing, mainly due to increased bacteraemia in patients with intravascular devices,...

  • Spondylodiscitis, nephrology department's experience. Ramírez-Huaranga, Marco A.; de la Nieta-García, M. Dolores Sánchez; Anaya-Fernández, Sara; Arambarri-Segura, Minerva; Caparrós-Tortosa, Guadalupe; Rivera-Hernández, Francisco; Romera-Segorbe, Ana; Vozmediano-Poyatos, M. Carmen; Ferreras-García, Isabel // Nefrologia;2013, Vol. 33 Issue 2, p250 

    Spondylodiscitis is an infection of the vertebral body and adjacent intervertebral discs, whose most common means of spreading is the haematogenous route. It is a rare disease but its overall incidence is increasing, mainly due to increased bacteraemia in patients with intravascular devices,...

  • Detection of coronary plaques using MR coronary vessel wall imaging: validation of findings with intravascular ultrasound. Gerretsen, Suzanne; Kessels, Alfons; Nelemans, Patty; Dijkstra, Jouke; Reiber, Johan; Geest, Rob; Katoh, Marcus; Waltenberger, Johannes; Engelshoven, Jos; Botnar, Rene; Kooi, M.; Leiner, Tim // European Radiology;Jan2013, Vol. 23 Issue 1, p115 

    Objectives: Compared with X-ray coronary angiography (CAG), magnetic resonance imaging of the coronary vessel wall (MR-CVW) may provide more information about plaque burden and coronary remodelling. We compared MR-CVW with intravascular ultrasound (IVUS), the standard of reference for coronary...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics