TITLE

Scanning Kelvin-probe study of the hydrogen-terminated diamond surface in ultrahigh vacuum

AUTHOR(S)
Pakes, C. I.; Hoxley, D.; Rabeau, J. R.; Edmonds, M. T.; Kalish, R.; Prawer, S.
PUB. DATE
September 2009
SOURCE
Applied Physics Letters;9/21/2009, Vol. 95 Issue 12, p123108
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Atomic-force and Kelvin-probe microscopies were employed in ultrahigh vacuum to image the surface topography and contact potential of the hydrogen-terminated and unterminated surfaces of diamond. A variation of about 25 meV in the contact potential was measured on a length scale of 20 nm and ascribed to differently orientated surface domains resulting from hydrogen-plasma processing of the sample. Shifts in the work function arising from sample heating in vacuum and the adsorption of C60 were measured. The Fermi level was found to be 0.7 and 1.1 eV below the valence band maximum for C60 coverages of 1 and 4 monolayer, respectively.
ACCESSION #
44374753

 

Related Articles

  • The interaction of hydrogen with a cobalt(1010) surface. Ernst, K.-H.; Schwarz, E.; Christmann, K. // Journal of Chemical Physics;9/15/1994, Vol. 101 Issue 6, p5388 

    The adsorption of hydrogen on a cobalt(1010) surface was investigated in ultrahigh vacuum (UHV) between 85 and 500 K using Video-LEED, temperature-programmed thermal desorption (TPD), work function (Δ[uppercase_phi_synonym]) measurements, and high-resolution electron energy loss spectroscopy...

  • Do's and Don'ts of Designing UHV Chambers. Comello, Vic // R&D Magazine;Oct99, Vol. 41 Issue 11, p18 

    Discusses the steps in designing an ultrahigh vacuum chamber for measuring the effects of molecular contamination on sensitive optical surfaces. Design process; Significance of sample handing; Requirements of the processes that will take place in the chamber. INSET: Special Enclosures Enable...

  • New getter pump for ultrahigh vacuum systems and transportable enclosure. Firpo, G.; Pozzo, A. // Review of Scientific Instruments;Nov2004, Vol. 75 Issue 11, p4828 

    We have developed a new type of nonevaporable getter (NEG) pump. It is based on the getter strip St707, produced by SAES getters S.p.A, fitted into a CF-flanged container. The pump is activated at 400°C for 1 h and its pumping behavior is studied for H2, CO, and N2. The pumping speed is about...

  • Cryogenic vacuum tribology of diamond and diamond-like carbon films. Aggleton, M.; Burton, J. C.; Taborek, P. // Journal of Applied Physics;Jul2009, Vol. 106 Issue 1, p13504 

    Friction measurements have been performed on microcrystalline, ultrananocrystalline, and diamond-like carbon (DLC) films with natural diamond counterfaces in the temperature range of 8 K to room temperature. All films exhibit low friction (μ≤0.1) in air at room temperature. In ultrahigh...

  • Construction of an innovative heating apparatus for ultrahigh vacuum platens used in high pressure reaction cells. Romano, Esteban J.; Schulz, Kirk H. // Review of Scientific Instruments;Apr2004, Vol. 75 Issue 4, p983 

    A robust heater for use with platen sample holders which are incorporated on commercial ultrahigh vacuum (UHV) reaction cells is described. The system is built with readily available commercial parts and requires minimal tooling for construction. The heater, as built in this publication, will...

  • An alternative for gas dosing in ultrahigh vacuum adsorption studies. Glines, Andrew M.; Carter, Robert N.; Anton, A. Brad // Review of Scientific Instruments;Feb1992, Vol. 63 Issue 2, p1826 

    We describe the design, construction, calibration, and operation of a dosing system for controlled exposures of solid surfaces to gases in ultrahigh vacuum. The doser includes seven parallel tubes in a hexagonal pattern, sized to give nearly uniform flux over a 6-mm-diam circle on the sample,...

  • Ultrahigh vacuum compatible all-glass high pressure reaction cell for accurate and reproducible measurement of small reaction rates. Reichl, W.; Rosina, G.; Rupprechter, G.; Zimmermann, C.; Hayek, K. // Review of Scientific Instruments;Mar2000, Vol. 71 Issue 3 

    An ultrahigh vacuum preparation and analysis chamber with an externally attached high pressure reaction cell is described. The novel all-glass design of the reaction cell allows the study of reaction kinetics in a clean environment but under conditions close to those of conventional catalysis....

  • Apparatus for adsorption studies. Rocca, M.; Valbusa, U.; Gussoni, A.; Maloberti, G.; Racca, L. // Review of Scientific Instruments;Sep91, Vol. 62 Issue 9, p2172 

    In this paper a UHV apparatus for studying adsorption of gases on surfaces will be described. The system is specifically designed for measuring the sticking coefficient of a molecule on the surface and its dependence on energy and angle of incidence. The method is based on the use of an electron...

  • Laser plasma source of amorphic diamond. Collins, C. B.; Davanloo, F.; Juengerman, E. M.; Osborn, W. R.; Jander, D. R. // Applied Physics Letters;1/16/1989, Vol. 54 Issue 3, p216 

    Amorphic diamond films characterized by a high percentage of sp3 bonds have been prepared in an UHV environment with a laser plasma source of carbon ions. Peak power densities in excess of 1011 W/cm2 were found necessary to produce films at growth rates of 0.5 μm/h over areas of 20 cm2 having...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics