ABSTRACT
Biological membranes constitute the set of membranes defining boundaries and organelles in living cells—the structural and functional building blocks of all known living organisms. The integrity of the cell depends on its ability to separate inside from outside and yet at the same time allow massive transport of matter in and out the cell. Nature has elegantly met this challenge by developing membranes in the form of lipid bilayers in which specialized and highly efficient transport proteins are incorporated. This raises the question: is it possible to mimic biological membranes and create membrane-based sensor and/or separation devices? In the development of biomimetic sensor/separation technology, both channels (ion and water channels) and carriers (transporters) are important. Generally, each class of transport proteins conducts specific molecular species in and out of the cell while preventing the passage of others, a property critical for the overall conservation of the cells internal pH and salt concentration. Both ion and water channels are highly efficient membrane pore proteins capable of transporting solutes at very high rates, up to 109 molecules per second. Carrier proteins generally have a lower turnover but are capable of transport against gradients. For both classes of proteins, their unique flux-properties make them interesting as candidates in biomimetic sensor/separation devices. An ideal sensor/separation device requires the supporting biomimetic matrix to be virtually impermeable to anything but the solute in question. In practice, however, a biomimetic support matrix will generally have finite permeabilities to water, electrolytes, and non-electrolytes. The feasibility of a biomimetic device thus depends on the relative transport contribution from both protein and biomimetic support matrix. Also the stability of the incorporated protein must be addressed and the protein-biomimetic matrix must be encapsulated in order to protect it and make it sufficiently stable in a final application. Here I will review and discuss these challenges and how they are met in some current developments of biomimetic sensor/separation devices.
ACCESSION #
44217532

 

Related Articles

  • Microfabrication of biomedical lab-on-chip devices. A review. Giannitsis, Athanasios T. // Estonian Journal of Engineering;Jun2011, Vol. 17 Issue 2, p109 

    No abstract available.

  • Screening of Aptamers on Microfluidic Systems for Clinical Applications. Weng, Chen-Hsun; Huang, Chao-Jyun; Lee, Gwo-Bin // Sensors (14248220);2012, Vol. 12 Issue 7, p9514 

    The use of microfluidic systems for screening of aptamers and their biomedical applications are reviewed in this paper. Aptamers with different nucleic acid sequences have been extensively studied and the results demonstrated a strong binding affinity to target molecules such that they can be...

  • Bioconjugation techniques for microfluidic biosensors. Goddard, Julie M.; Erickson, David // Analytical & Bioanalytical Chemistry;May2009, Vol. 394 Issue 2, p469 

    We have evaluated five bioconjugation chemistries for immobilizing DNA onto silicon substrates for microfluidic biosensing applications. Conjugation by organosilanes is compared with linkage by carbonyldiimidazole (CDI) activation of silanol groups and utilization of dendrimers. Chemistries were...

  • New directions in medical biosensors employing poly(3,4-ethylenedioxy thiophene) derivative-based electrodes. Rozlosnik, Noemi // Analytical & Bioanalytical Chemistry;Oct2009, Vol. 395 Issue 3, p637 

    Demand is growing in the field of medical diagnostics for simple, disposable devices that also demonstrate fast response times, are easy to handle, are cost-efficient, and are suitable for mass production. Polymer-based microfluidic devices meet the requirements of cost efficiency and mass...

  • A Gentler Reveille.  // Technology Review;Jul/Aug2011, Vol. 114 Issue 4, p18 

    Information on the Wakemate armband from Perfect Third is presented.

  • The Measured Life. SINGER, EMILY // Technology Review;Jul/Aug2011, Vol. 114 Issue 4, p38 

    Information on new types of devices that monitor activity, sleep, diet and even mood including the Zeo monitor that tracks one's sleep, a startup's device that tracks heart rate, body temperature, movement and sweat levels, and the BodyMedia armband that tracks calories burned is presented.

  • Design, Fabrication and Characterization of a Low-Impedance 3D Electrode Array System for Neuro-Electrophysiology. Kusko, Mihaela; Craciunoiu, Florea; Amuzescu, Bogdan; Halitzchi, Ferdinand; Selescu, Tudor; Radoi, Antonio; Popescu, Marian; Simion, Monica; Bragaru, Adina; Ignat, Teodora // Sensors (14248220);Dec2012, Vol. 12 Issue 12, p16571 

    Recent progress in patterned microelectrode manufacturing technology and microfluidics has opened the way to a large variety of cellular and molecular biosensor-based applications. In this extremely diverse and rapidly expanding landscape, silicon-based technologies occupy a special position,...

  • Chemistry in nanochannel confinement. Gardeniers, Han J. G. E. // Analytical & Bioanalytical Chemistry;May2009, Vol. 394 Issue 2, p385 

    This review addresses the questions of whether it makes sense to use lithographically defined nanochannels for chemistry in liquids, and what it is possible to learn from experiments on that topic. The behavior of liquids in different classes of pores (categorized according to their size) is...

  • Electrospinning of PCL/PVP blends for tissue engineering scaffolds. Kim, Gyeong-Man; Le, Kim; Giannitelli, Sara; Lee, Yu; Rainer, Alberto; Trombetta, Marcella // Journal of Materials Science: Materials in Medicine;Jun2013, Vol. 24 Issue 6, p1425 

    Currently, one of the main drawbacks of using poly( ε-caprolactone) in the biomedical and pharmaceutical fields is represented by its low biodegradation rate. To overcome this limitation, electrospinning of PCL blended with a water-soluble poly( N-vinyl-2-pyrrolidone) was used to fabricate...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics