TITLE

Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer

AUTHOR(S)
Hoevers, H. F. C.; Hoevers, H.F.C.; Bento, A. C.; Bento, A.C.; Bruijn, M. P.; Bruijn, M.P.; Gottardi, L.; Korevaar, M. A. N.; Korevaar, M.A.N.; Mels, W. A.; Mels, W.A.; de Korte, P. A. J.; de Korte, P.A.J.
PUB. DATE
December 2000
SOURCE
Applied Physics Letters;12/25/2000, Vol. 77 Issue 26
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The current noise at the output of a microcalorimeter with a voltage biased superconducting transition edge thermometer is studied in detail. In addition to the two well-known noise sources: thermal fluctuation noise from the heat link to the bath and Johnson noise from the resistive thermometer, a third noise source strongly correlated with the steepness of the thermometer is required to fit the measured noise spectra. Thermal fluctuation noise, originating in the thermometer itself, fully explains the additional noise. A simple model provides quantitative agreement between the observed and calculated noise spectra for all bias points in the superconducting transition. © 2000 American Institute of Physics.
ACCESSION #
4414826

 

Related Articles

  • Performance of Mo/Au TES microcalorimeters. Lindeman, Mark A.; Brekosky, Regis P.; Figueroa-Feliciano, Enectali; Finkbeiner, Fred M.; Li, Mary; Stahle, Caroline K.; Stahle, Carl M.; Tralshawala, Nilesh // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p203 

    We are developing X-ray calorimeters to meet the specifications of the ConstellationX mission. Each calorimeter consists of a transition-edge-sensor (TES) thermometer, which is suspended on a silicon-nitride membrane. Our TES thermometers are Mo/Au bilayer films that are biased in the sharp...

  • Nanoscale radio-frequency thermometry. Schmidt, D. R.; Yung, C. S.; Cleland, A. N. // Applied Physics Letters;8/4/2003, Vol. 83 Issue 5, p1002 

    We experimentally demonstrate the high bandwidth readout of a thermometer based on a superconductor-insulator-normal metal (SIN) tunnel junction, embedded in a rf resonant circuit. Our implementation enables basic studies of the thermodynamics of mesoscopic nanostructures. It can also be applied...

  • Performance of Resistive Microcalorimeters and Bolometers. Galeazzi, Massimiliano // AIP Conference Proceedings;2006, Vol. 850 Issue 1, p1599 

    In recent years microcalorimeters and bolometers have achieved impressive performance in terms of energy resolution or Noise Equivalent Power (NEP). However their performance is still significantly worse than predicted by ideal models. The difference is due primarily to non-ideal effects that...

  • Results of CRESST phase I. Cozzini, C.; Altmann, M.; Angloher, G.; Bruckmayer, M.; Bucci, C.; Cooper, S.; Di Stefano, P.; von Feilitzsch, F.; Frank, T.; Hauff, D.; Jagemann, Th.; Jochum, J.; Keeling, R.; Kraus, H.; Macallister, J.; Pro¨bst, F.; Ramachers, Y.; Schnagl, J.; Seidel, W.; Sergeyev, I. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p481 

    Results of the CRESST experiment at Gran Sasso using 262 g sapphire calorimeters with tungsten phase transition thermometers are presented. Calibration and analysis methods are described. Data taken in 2000 have been used to place limits on WIMP dark matter particles in the galactic halo. The...

  • Performance of X-ray microcalorimeters with an energy resolution below 4.5 eV and 100 μs response time. Tiest, W. M. Bergmann; Hoevers, H. F. C.; Mels, W. A.; Ridder, M. L.; Bruijn, M. P.; de Korte, P. A. J.; Huber, M. E. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p199 

    The performance of X-ray microcalorimeters with a Ti/Au Transition Edge Sensor (TES) and a Cu absorber has been investigated. With these microcalorimeters we achieve energy resolutions below 4.5 eV FWHM for 5.89 keV X-rays in combination with a response time of about 100 µs. The measured...

  • ac calorimeter for measurements of adsorbed gases on metal films at 4He temperatures. Kenny, T. W.; Richards, P. L. // Review of Scientific Instruments;Feb1990, Vol. 61 Issue 2, p822 

    An analysis is presented of the performance of an ideal ac calorimeter limited only by thermodynamic noise. A calorimeter based on this analysis is described which is designed for studies of the heat capacity of monolayers and multilayers of atoms and molecules adsorbed on a variety of surfaces....

  • Transition edge sensors for imaging spectrometers. Hoevers, H. F. C. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p193 

    This paper describes single pixel microcalorimeters with a superconductor-to-normal phase transition thermometer, as developed for high resolution X-ray spectroscopy, and discusses the discrepancies between their theoretical and experimental performance. Moreover, the status and development of...

  • The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory. Kelley, R. L.; Bandler, S. R.; Doriese, W. B.; Ezoe, Y.; Fujimoto, R.; Gottardi, L.; den Hartog, R.; den Herder, J.-W.; Hoevers, H.; Irwin, K.; Ishisaki, Y.; Kilbourne, C. A.; de Korte, P.; van der Kuur, J.; Mitsuda, K.; Ohashi, T.; Piro, L.; Porter, F. S.; Sato, K.; Shinozaki, K. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p757 

    The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for...

  • calorimeter.  // Hutchinson Dictionary of Scientific Biography;2005, p1 

    Instrument used in the determination of quantities of heat change.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics