TITLE

Scanning calorimeter for nanoliter-scale liquid samples

AUTHOR(S)
Olson, E. A.; Olson, E.A.; Efremov, M. Yu.; Efremov, M. Yu; Kwan, A. T.; Kwan, A.T.; Lai, S.; Petrova, V.; Schiettekatte, F.; Shiettekatte, F.; Warren, J. T.; Warren, J.T.; Zhang, M.; Allen, L. H.; Allen, L.H.
PUB. DATE
October 2000
SOURCE
Applied Physics Letters;10/23/2000, Vol. 77 Issue 17
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We introduce a scanning calorimeter for use with a single solid or liquid sample with a volume down to a few nanoliters. Its use is demonstrated with the melting of 52 nL of indium, using heating rates from 100 to 1000 K/s. The heat of fusion was measured to within 5% of the bulk value, and the sensitivity of the measurement was ±7 μW. The heat of vaporization of water was measured in the scanning mode to be within ±23% of the bulk value by actively vaporizing water droplets from 2 to 100 nL in volume. Results within 25% were obtained for the heat of vaporization by using the calorimeter in a heat-conductive mode and measuring the passive evaporation of water. Temperature measurements over a period of 10 h had a standard deviation of 3 mK. © 2000 American Institute of Physics.
ACCESSION #
4414664

 

Related Articles

  • calorimeter.  // Taber's Cyclopedic Medical Dictionary (2009);2009, Issue 21, p342 

    An encyclopedia entry for "calorimeter" is presented.

  • Automated, small sample-size adiabatic calorimeter. Van Oort, Michiel J. M.; White, Mary Anne // Review of Scientific Instruments;Jul1987, Vol. 58 Issue 7, p1239 

    An automated adiabatic calorimeter with an internal volume of 5 cm3, operable over the temperature range from 30 to 380 K is described. One of the main advantages of this calorimeter over others in use is the much abbreviated down time during sample changes, due to interchangeable sample vessels...

  • Development of a high-sensitivity, computer-controlled titration calorimeter. Baisden, P. A.; Grant, P. M.; Kinard, W. F. // Review of Scientific Instruments;Oct87, Vol. 58 Issue 10, p1937 

    A highly sensitive, adiabatic titration calorimeter controlled by a personal computer is described. Operation of the entire calorimetric titration is automated, including the thermoelectric offset of the heat of stirring, the electrical calibration of the heat capacity, the addition of titrant,...

  • High-pressure photoacoustic calorimetry. Daffron, John A.; Farrell, Gerard J.; Burkey, Theodore J. // Review of Scientific Instruments;Oct2000, Vol. 71 Issue 10 

    A high-pressure photoacoustic calorimeter has been developed to operate up to 200 MPa. Photoacoustic calorimetry can be used to study the microsecond kinetics and thermodynamics of reactions in solution. Both thermal expansion and volume of reaction contribute to the generation of the...

  • A modified dual-slope method for heat capacity measurements of condensable gases. Pilla, S.; Hamida, J. A.; Hamida, J.A.; Sullivan, N. S.; Sullivan, N.S. // Review of Scientific Instruments;Oct2000, Vol. 71 Issue 10 

    A high resolution nonadiabatic method for measuring the heat capacity (C[sub P]) of bulk samples of condensable gases in the range of 7.5-70 K is described. In this method C[sub P] is evaluated by directly comparing the heating and cooling rates of the sample temperature for two algebraically...

  • Differential microcalorimeter for liquid samples. Barbini, A.; Bertolini, D.; Cassettari, M.; Papucci, F.; Salvetti, A.; Salvetti, G.; Veronesi, S. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1308 

    A microcalorimeter for liquid samples with high performance and low cost is described. It is essentially a differential apparatus in a ‘‘twin’’ configuration with two cylindrical cells. Two resistive sensors, put in a Wheatstone bridge, are wound on the cells to measure...

  • An isothermal scanning calorimeter controlled by linear pressure variations from 0.1 to 400 MPa. Calibration and comparison with the piezothermal technique. Randzio, Stanislaw L.; Grolier, Jean-Pierre E.; Quint, Jacques R. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p960 

    An isothermal scanning calorimeter controlled by linear pressure variations is described for the pressure range 0.1-400 MPa at temperatures from 303 to 573 K. The rate of pressure variations can be as low as 0.002 MPa/s over the whole pressure range. The functioning of the instrument was tested...

  • The 2009-2014 Outlook for Calorimeters and Thermal Analysis Equipment in India. Parker, Philip M. // Country Outlook Reports;1/ 2/2010, pN.PAG 

    Several charts are presented that depict the 2009-2014 outlook for calorimeters and thermal analysis equipment in various cities in India including Kanpur, Pune, and Kolkata.

  • ac nanocalorimeter for measuring heat capacity of biological macromolecules in solution. Haruhiko Yao; Kenji Ema; Harumi Fukada; Katsutada Takahashi; Ichiro Hatta // Review of Scientific Instruments;Sep2003, Vol. 74 Issue 9, p4164 

    A precise calorimeter has been developed to measure the heat capacity of a small amount of liquid using a novel ac calorimetric method in which the effect of heat loss from a sample cell is corrected using the phase of the ac temperature. The sample cell is made of a fine glass tube, whose outer...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics