ABSTRACT
Here a new conductivity probe, which is basically a stainless steel tube with a plastic plug with a hole, plugged in one end, is described. The tube is externally insulated and the other electrode is (usually earthed) a metallic slab fixed in the fluid. The electronic used is of a conventional type and uses a 1 kHz signal whose amplitude is modulated by the conductance across the probes terminals. The signal is amplified, rectified, and filtered. The probe is different from the conventional probes, in that the fluid is sucked through the small hole in the probe tip, and only through the fluid in the tip can an electric current flow. Hence, the output and the dynamic response depend, respectively, on the conductivity of the small volume of the fluid in the tip, and how fast it can be replaced. Tests on this and other types of probes, show that this probe has almost no drift and has a satisfactory dynamic response. Probes with different tip geometries have also been tested and show that the frequency response of the probe (typically 200 Hz) does not change significantly. Possible adaptation of such a probe for oceanographic measurements will be discussed. The author has successfully used such a system for laboratory study of turbulence in stratified fluids. © 2000 American Institute of Physics.
ACCESSION #
4410276

 

Related Articles

  • Active low frequency vertical vibration isolation. Hensley, Joel M.; Peters, Achim; Chu, Steven // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2735 

    Describes the construction of a system that isolates a key element of an experimental setup from vertical motions of the ground and the surrounding apparatus. Theory; Mechanical system; Electronic feedback; Alignment.

  • Feasibility and applicability of integrated metrology using spectroscopic ellipsometry in a cluster tool. Piel, J. Ph.; Boher, P.; Stehle´, J. L.; Pickering, C. // AIP Conference Proceedings;2001, Vol. 550 Issue 1, p538 

    For any industrial integrated metrology application three key issues must be addressed - feasibility, applicability and cost-effectiveness. This paper reports progress on the integration of spectroscopic ellipsometry (SE) in the cool-down chamber. SE is capable of providing rapid information on...

  • Three-in-one functionality. whitel // MWP (Online Edition);10/ 4/2012, p207 

    The article evaluates Talyrond 500 instruments for roundness, form and surface finish measurements.

  • Instrument for the in situ measurement of haze in aircraft windscreens. Gallagher III, Frank W.; Brock, Fred V. // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2083 

    Reports on the development of a prototype instrument that measures haze in aircraft windscreens. Elimination of ambient light and compensation for the remaining illumination; Need for precise orientation of the collimator and the integrating sphere.

  • Absolute calibration of nuclear activation diagnostics for intense pulsed ion beams. Young, F.C.; Boller, J.R.; Stephanakis, S.J. // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2182 

    Describes absolute calibration of an annihilation-radiation sodium iodide (NaI) coincidence detection system for short-lived ion-induced radioactivity. Incident proton intensity; Comparison of absolute fluences of pulsed proton beams with ion beam fluences measured by carbon calorimetry.

  • Apparatus for the rapid measurement of electrical transport properties for both "needle-like" and bulk materials. Pope, A. L.; Littleton, R. T.; Tritt, Terry M. // Review of Scientific Instruments;Jul2001, Vol. 72 Issue 7, p3129 

    Described in this article is an apparatus in which thermopower and resistivity can be measured almost simultaneously from 10 to 300 K in a closed cycle refrigerator system. A distinction of this system is that the samples are mounted on integrated circuit (IC) chips for rapid introduction of the...

  • New surface forces apparatus using two-beam interferometry. Kawai, Hiroshi; Sakuma, Hiroshi; Mizukami, Masashi; Abe, Takashi; Fukao, Yasuhiro; Tajima, Haruo; Kurihara, Kazue // Review of Scientific Instruments;Apr2008, Vol. 79 Issue 4, p043701 

    We designed a new surface forces apparatus for measuring the interactions between two nontransparent substrates and/or in nontransparent liquids. The small displacement of a surface, the bottom one in this study, was measured by the two-beam (twin path) interferometry technique using the phase...

  • Plateau tank apparatus for the study of liquid bridges. Resnick, A.; Alexander, J.I.D. // Review of Scientific Instruments;Mar97, Vol. 68 Issue 3, p1495 

    Focuses on apparatus used to study the equilibrium and dynamical behavior of liquid bridges under reduced effective gravity. Creation and manipulation of liquid bridges using independent computer controlled stepper motors which drive linear motion tables; Visualization of the bridges with a...

  • A calibration standard for laser-Doppler perfusion measurements. Liebert, A.; Leahy, M.; Maniewski, R. // Review of Scientific Instruments;Nov95, Vol. 66 Issue 11, p5169 

    Describes the development of a calibration standard for the laser-Doppler perfusion monitors. Inadequacies of the common method of calibration that relies on the Brownian motion of latex microspheres in water solution; Power spectral density of laser-Doppler signals; Introduction of a static...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics