TITLE

Development of special rotor for centrifugal separation of isotopes in solid pure metals

AUTHOR(S)
Ono, Masao; Sueyoshi, Masanori; Okayasu, Satoru; Ting Hao; Esaka, Fumitaka; Osawa, Takahito; Iguchi, Yusuke; Mashimo, Tsutomu
PUB. DATE
August 2009
SOURCE
Review of Scientific Instruments;Aug2009, Vol. 80 Issue 8, p083908
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A prototype rotor with two grooves for the multistage centrifugal isotope separation in solid state was developed to test a new idea. This idea is based on the sedimentation of constitutional atoms in solid. In the performance test using indium specimen, it is verified that the developed rotor can receive all injected molten-indium droplets from an automatic raw-material feeding system even at the high rotational speed of 97 000 rpm without the loss of rotational stability, and the received indium specimens can be transferred in/between two grooves through the plastic flow under the influence of strong centrifugal force even in the solid state. The isotope ratio of centrifuged indium specimens was analyzed employing the secondary ion mass spectrometry, and it is confirmed that intended isotope separation by the centrifugation is realized in the solid state. The developed rotor can be used to perform the isotope separation on at least solid metals under the conditions of up to 400 °C in specimen temperature and 0.4×106g in centrifugal force field.
ACCESSION #
43975400

 

Related Articles

  • Analyzer combines MSRI and SIMS.  // R&D Magazine;Sep97, Vol. 39 Issue 10, p25 

    Focuses on the Mass Spectroscopy of Recoiled Ion Analyzer (MSRI) which provides surface analysis by MSRI and secondary ion mass spectroscopy (SIMS). What is monitored by the analyzer; Why surface analysis is not possible under these conditions using other techniques; Details on the utilization...

  • Where Is Gravity? Dalton, Cindy Devine; Sikora, Teresa; Sikora, Ed // Gravity;2001, p14 

    The chapter describes where gravity can be found. Gravity is everywhere, even in space. The gravitational pull of the Earth keeps the Space Shuttle in orbit around it. Centrifugal force is discussed.

  • Field-induced segregation effects during secondary-ion mass spectrometry depth profiling of Cu and Na implanted in silicon. Vriezema, C. J.; Janssen, K. T. F.; Boudewijn, P. R. // Applied Physics Letters;5/15/1989, Vol. 54 Issue 20, p1981 

    Segregation effects during secondary-ion mass spectrometry (SIMS) depth profiling of Cu and Na implanted in n- and p-type Si are investigated under different oxygen bombardment conditions. The segregation effects are studied also with SIMS using Cs bombardment. These experiments revealed that Cu...

  • Secondary ion mass spectroscopy study of Zn or Cd implanted and rapid thermally annealed Pd/Ge.... Ressel, P.; Strusny, H. // Applied Physics Letters;8/29/1994, Vol. 65 Issue 9, p1174 

    Examines elemental redistribution in zinc or cadmium implanted Pd/Ge contacts to p-InGaAs using backside secondary ion mass spectroscopy. Observation of Pd-In-Ga-As layer at annealing temperatures; Diffusion of germanium to the contact interface; Potential of Pd/Ge contact to be a shallow ohmic...

  • CF4/O2 plasma induced damage in Si-implanted n-type GaAs crystals. Wada, Jun; Matsukura, Yusuke // Journal of Applied Physics;7/15/1997, Vol. 82 Issue 2, p617 

    Studies the CF4/O2 or CF4 plasma induced damage in Si-implanted n-type GaAs crystals with the use of Hall measurement and secondary ion mass spectrometry (SIMS) analysis. Degradation of the sheet resistance during postannealing; Fluorine contamination observed in the surface region of the crystals.

  • Isotopic tracer studies of oxygen transport through SiO2 films at 1000 °C using secondary ion mass spectrometry. Han, C. J.; Helms, C. R. // Journal of Applied Physics;3/1/1986, Vol. 59 Issue 5, p1767 

    Analyzes dry oxides grown on silicon at 1000 ° Celsius at 1 atm using purified [sup16]Oxygen[sub2] and purified [sup18]Oxygen[sub2] employing secondary ion mass spectrometry (SIMS). SIMS profile of an oxide sample; Information on the diffusion rate for lattice oxygen near the interface.

  • Characterization of the noise in secondary ion mass spectrometry depth profiles. Chu, D. P.; Dowsett, M. G.; Cooke, G. A. // Journal of Applied Physics;12/15/1996, Vol. 80 Issue 12, p7104 

    Presents a study which characterized the noise in secondary ion mass spectrometry (SIMS) depth profiles. Use of the Poissonian relation between the measured mean-square error and mean; Sources of SIMS; Separation of noise from signals.

  • Examination of deuterium transport through device structures. Chen, P. J.; Wallace, R. M. // Applied Physics Letters;12/7/1998, Vol. 73 Issue 23 

    We use secondary ion mass spectrometry to characterize the hydrogen/deuterium distribution and concentration on 0.18 μm “metal” oxide silicon test structures subjected to deuterium anneals. We examine the temperature dependence and the influence of doping on the transport of...

  • Carbon diffusion in undoped, n-type, and p-type GaAs. Cunningham, B. T.; Guido, L. J.; Baker, J. E.; Major, J. S.; Holonyak, N.; Stillman, G. E. // Applied Physics Letters;8/14/1989, Vol. 55 Issue 7, p687 

    The effects of background doping, surface encapsulation, and As4 overpressure on carbon diffusion have been studied by annealing samples with 1000 Å p-type carbon doping spikes grown within 1 μm layers of undoped (n-), Se-doped (n+), and Mg-doped (p+) GaAs. The layers were grown by...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics