TITLE

Novel technique for investigating the temperature effect on the diffusion coefficient of

AUTHOR(S)
Ping-Hei Chen; Jr-Ming Miao; Ching-Sung Jian
PUB. DATE
August 1996
SOURCE
Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p2831
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a technique that uses a piezoelectronic quartz crystal microbalance in determining the diffusion coefficient of naphthalene into air. Measurement uncertainty of the diffusion of coefficient of naphthalene into air with the present system; Recommended use of an empirical correlation for researchers interested in employing the naphthalene sublimation technique.
ACCESSION #
4376466

 

Related Articles

  • Use of polyclonal antibodies to ochratoxin A with a quartz–crystal microbalance for developing real-time mycotoxin piezoelectric immunosensors. Vidal, J. C.; Duato, P.; Bonel, L.; Castillo, J. R. // Analytical & Bioanalytical Chemistry;May2009, Vol. 394 Issue 2, p575 

    A piezoelectric immunosensor was tested for ochratoxin A (OTA) mycotoxin detection through the immobilization of OTA–bovine serum albumin (OTA–BSA) conjugate on gold-coated quartz crystals (AT-cut/5 MHz). Immunoassays were performed in a flow-injection system through frequency...

  • Quartz crystal microbalance determination of vapors of volatile organic compounds on carbon nanotubes under batch conditions. Shogenov, Yu.; Kuchmenko, T.; Grazhulene, S.; Red'kin, A. // Journal of Analytical Chemistry;Jan2012, Vol. 67 Issue 1, p21 

    Specific features of the sorption of vapors of monoatomic aliphatic alcohols and aromatic compounds on coatings formed from carbon nanotubes of various genesis studied by the method of piezoelectric micro weighing are considered. The morphology of the coatings is considered in dependence on the...

  • Nanocrystalline diamond enhanced thickness shear mode resonator. Williams, Oliver A.; Mortet, Vincent; Daenen, Michael; Haenen, Ken // Applied Physics Letters;2/5/2007, Vol. 90 Issue 6, p063514 

    A nanocrystalline diamond coated thickness shear mode resonator has been fabricated as an alternative to the quartz crystal microbalance. Due to the low temperature phase transition of quartz, the piezoelectric material was replaced with langasite, a piezoelectric with no phase transition up to...

  • Active control scheme for improving mass resolution of film bulk acoustic resonators. He, Xue-feng; Liu, Xing; Yin, Xian-fang; Wen, Zhi-yu; Chen, Ke-wan // Applied Mathematics & Mechanics;Jun2011, Vol. 32 Issue 6, p749 

    High mass resolution of sensors based on film bulk acoustic resonators (FBARs) is required for the detection of small molecules with the low concentration. An active control scheme is presented to improve the mass resolution of the FBAR sensors by adding a feedback voltage onto the driving...

  • Analyzing Spur-Distorted Impedance Spectra for the QCM. Sae Moon Yoon; Nam Joon Cho; Kay Kanazawa // Journal of Sensors;2009, p1 

    The quartz crystal microbalance (QCM) is a sensitive device for determining the properties of materials loading it. One of the fundamental means of making these measurements is the so-called impedance (or admittance) spectra method. The resonant properties of the piezoelectric QCM sensor are...

  • Determination of flux ionization fraction using a quartz crystal microbalance and a gridded... Green, K.M.; Hayden, D.B.; Juliano, D.R; Ruiz, D.N. // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4555 

    Reports on the determination of flux ionization fraction using a quartz crystal microbalance (QCM) and a gridded energy analyzer in an ionized magnetron sputtering system. Mounting of the sensor on a linear motion; Introduction of radio-frequency power through a coil; Determination of the metal...

  • Piezoelectric crystals enhance detection of biologicals. Cassidy, Robert // R&D Magazine;Jan95, Vol. 37 Issue 1, p50 

    Features piezoelectric (PZ) quartz crystal microbalance (QCM) systems useful for researchers as a fast, direct and cheaper method for real-time measurement of biomolecular reactions. Uses; Benefits; Developments in the field of PZ crystals. INSET: How PZ Biosensors work..

  • Erratum: Quartz crystal microbalance thin-film dissolution [Rev. Sci. Instrum. 60, 489 (1989)]. Hinsberg, William D.; Kanazawa, Kay K. // Review of Scientific Instruments;Dec1989, Vol. 60 Issue 12, p3835 

    Presents a correction to a research article on quartz crystal microbalance thin-film dissolution published in a 1989 issue of the journal 'Review of Scientific Instruments.'

  • Phase-frequency relationships in oscillating quartz microbalance electrodes: Determination of an... Komplin, Glenn C.; Pietro, William J. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1131 

    Presents a systematic study of the effects of overtone harmonic, operating frequency, and electrode surface area on mass sensitivity of liquid-phase quartz-crystal microbalance (QCM) operation. Complex impedance measurements; Electrical characteristics of the QCM; Complex impedance of...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics