TITLE

Digital image processing of images obtained with a Pu-Be(~10[Sup 7]) neutron source

AUTHOR(S)
Panchal, C.G.; Sinha, A.; Bhawe, B.D.; Shyam, A.; Srinivasan, M.; Joshi, V.M.
PUB. DATE
August 1996
SOURCE
Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p2775
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Demonstrates improvements in a nuclear particle scintillation imaging system by implementing image enhancement techniques which overcome some of the difficulties associated with small scale radiography systems. Description of the image capture device, some of the basic algorithms and an approach for better visualization of image details.
ACCESSION #
4376459

 

Related Articles

  • Direct search for dark matter particles deep underground by DAMA experiment. Belli, P.; Bernabei, R.; Cerulli, R.; Montecchia, F.; Amato, M.; Ignesti, G.; Incicchitti, A.; Prosperi, D.; Dai, C. J.; He, H. H.; Kuang, H. H.; Ma, J. M. // AIP Conference Proceedings;2001, Vol. 586 Issue 1, p95 

    DAMA is searching for rare processes by developing and using several kinds of radiopure scintillators: NaI(Tl), liquid Xenon and CaF[SUB2](Eu). Here, in particular, results achieved during four annual cycles with a model independent analysis and with model dependent ones in the investigation of...

  • Development of scintillation materials for medical imaging and other applications. Melcher, C. L. // AIP Conference Proceedings;Feb2013, Vol. 1512 Issue 1, p1310 

    Scintillation materials that produce pulses of visible light in response to the absorption of energetic photons, neutrons, and charged particles, are widely used in various applications that require the detection of radiation. The discovery and development of new scintillators has accelerated in...

  • New limit of the G-parity irregular weak nucleon current detected in β decays of spin aligned [sup 12]B and [sup 12]N. Minamisono, K.; Matsuta, K.; Minamisono, T.; Yamaguchi, T.; Sumikama, T.; Nagatomo, T.; Ogura, M.; Iwakoshi, T.; Fukuda, M.; Mihara, M.; Koshigiri, K.; Morita, M. // AIP Conference Proceedings;2002, Vol. 610 Issue 1, p1044 

    The G-parity irregular induced tensor form factor in the weak nucleon axial vector current has been precisely determined by measuring the alignment correlation terms in the β-ray angular distributions of the purely spin aligned mirror pair [sup 12]B(I[sup π]=1[sup +],T[sub 1/2]=20.2 ms)...

  • On the Influence of Ionization Density in a Fast Charged Particle Track on the Light Output of Scintillations. Lyapidevskii, V. K.; Ryazanov, M. I. // Technical Physics;Jul2000, Vol. 45 Issue 7, p948 

    It is shown that ionization density due to a fast charged particle influences the light output of a scintillator through the relaxation transition of an electron from an impurity atom to a host-material ion.

  • A silicon strip detector system for high resolution particle tracking in turbulence. Voth, Greg A.; Porta, Arthur La; Crawford, Alice M.; Bodenschatz, Eberhard; Ward, Curt; Alexander, Jim // Review of Scientific Instruments;Dec2001, Vol. 72 Issue 12, p4348 

    We describe a high speed imaging system that is used to track tracer particles in highly turbulent flows. The system uses silicon strip detectors designed for high energy physics experiments and is capable of reading two detectors at a frame rate of 70 kHz. Each detector contains 512 strips and...

  • High-sensitivity scintillating-fiber imaging detector for high-energy neutrons. Ress, D.; Lerche, R.A.; Ellis, R.J.; Heaton, G.W.; Lehr, D.E. // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p4943 

    Presents a high-sensitivity scintillating-fiber imaging detector for high-energy neutrons. Conversion of the neutron radiation to blue light; Description of each fiber; Testing of the fiber-optic readout system; Characterization of the overall efficiency of the detector using the DT-fusion...

  • Helicity of orientation parameters of photofragments in fluorescence-imaging experiments. Kuo-mei CHen; Cheng-chih Pei // Journal of Chemical Physics;10/22/1998, Vol. 109 Issue 16, p6647 

    Examines the detection scheme in fluorescence-imaging. Aim in determining helicity of photofragment orientation parameters; Usage of polarized photolysis lasers in helicity determination; Establishment of a pattern recognition from fluorescence images of photofragment in helicity state;...

  • Interaction of Electron Neutrinos with 56Fe in the LSD for Eνe ≤ 50 MeV. Gaponov, Yu. V.; Ryazhskaya, O. G.; Semenov, S. V. // Physics of Atomic Nuclei;Nov2004, Vol. 67 Issue 11, p1969 

    The neutrino pulses detected by the LSD (Liquid Scintillator Detector) on February 23, 1987, are analyzed on the basis of a two-stage model of supernova explosion. The number of events due to the electron-neutrino interaction with 56Fe in the LSD is calculated. The obtained number of signals is...

  • New Organic Scintillators for Neutron Detection. Iwanowska, Joanna; Szczęśniak, Tomasz // AIP Conference Proceedings;1/5/2010, Vol. 1204 Issue 1, p165 

    This paper present the current work on neutron detection in Soltan Institute for Nuclear Studies. Lately, we have focused our research on the development of new organic scintillators including liquid scintillators for neutron detection and associated measurements. We measured liquid...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics