TITLE

Photonic sensor devices for explosive detection

AUTHOR(S)
Willer, Ulrike; Schade, Wolfgang
PUB. DATE
September 2009
SOURCE
Analytical & Bioanalytical Chemistry;Sep2009, Vol. 395 Issue 2, p275
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
For the sensitive online and in situ detection of gaseous species, optical methods are ideally suited. In contrast to chemical analysis, no sample preparation is necessary and therefore spectroscopic methods should be favorable both in respect of a fast signal recovery and economically because no disposal is needed. However, spectroscopic methods are currently not widely used for security applications. We review photonic sensor devices for the detection of explosives in the gas phase as well as the condensed phase and the underlying spectroscopic techniques with respect to their adaptability for security applications, where high sensitivity, high selectivity, and a low false-alarm rate are of importance. The measurements have to be performed under ambient conditions and often remote handling or even operation in standoff configuration is needed. For handheld and portable equipment, special attention is focused on the miniaturization and examples for already-available sensor devices are given.
ACCESSION #
43707191

 

Related Articles

  • PRODUCTS.  // LC-GC Europe;Jul2003, Vol. 16 Issue 7, p438 

    Features several products in analytical chemistry. Photon detectors; Viscosity and light scattering detectors; Capillary columns; Mass spectrometry software; Flash columns and cartridges; Polyolefin characterization.

  • High spectral resolution, photon counting detector for Doppler temperature measurements in magnetically confined plasmas. Benjamin, R. D.; Terry, J. L.; Moos, H. W. // Review of Scientific Instruments;Apr87, Vol. 58 Issue 4, p520 

    This paper describes the design, construction, and performance of a single-stage microchannelplate image intensifier used as a photon counting detector over the wavelength range from 1150 to ∼2000 Å. The intensifer incorporates three high strip current (∼ 300 µA) microchannel...

  • Optical gas detection using metal film enhanced leaky mode spectroscopy. Osterfeld, M.; Franke, H.; Feger, C. // Applied Physics Letters;5/10/1993, Vol. 62 Issue 19, p2310 

    Performs optical gas detection using metal film enhanced leaky mode spectroscopy. Importance of optical sensors in aggressive environment application; Application of the Kretschmann geometry technique in combination with amorphous fluorocarbon film; Dependence of the response duration on size...

  • Bandpass photon detector with high efficiency for inverse photoemission spectroscopy. Schäfer, I.; Drube, W.; Schlüter, M.; Plagemann, G.; Skibowski, M. // Review of Scientific Instruments;Apr87, Vol. 58 Issue 4, p710 

    We report on a significant improvement of a simple, but effective bandpass photon detector specially suited for inverse photoemission studies. It consists of a commercial open CuBe multiplier with a CaF[sub 2] entrance window. The latter acts as a low pass, the high pass and the quantum...

  • A new nonclipped correlator for photon count spectroscopy. Correia, Carlos; Santos, Filomena P. // Review of Scientific Instruments;Sep89, Vol. 60 Issue 9, p2937 

    A circuit for photon count spectroscopy and its interface to a digital signal processor (DSP) are described. The complete circuit is housed in a standard IBM-PC board and, as it contains its own processor and memory, has a background mode of operation that releases the host system for being used...

  • Products.  // Spectroscopy;Oct2001, Vol. 16 Issue 10, p50 

    Evaluates several spectroscopic devices. CoatMaster 450 XRF coating thickness measurement system from Edax; AutoPellet press used in sample preparation for x-ray spectroscopy from Carver; Infrared Variable Angle Spectroscopic Ellipsometer for thin film characterization from J.A. Woollam.

  • Elimination of endpoint-discontinuity artifacts in the analysis of spectra in reciprocal space. Yoo, S. D.; Aspnes, D. E. // Journal of Applied Physics;6/15/2001, Vol. 89 Issue 12, p8183 

    Reciprocal-space analysis offers several advantages for determining critical point parameters in optical and other spectra, for example the separation of baseline effects, information, and noise in low-, medium-, and high-index Fourier coefficients, respectively. However, endpoint-discontinuity...

  • Calendar.  // Spectroscopy;Dec2004, Vol. 19 Issue 12, p130 

    Presents a calendar of activities in the spectroscopy sector for January 2005.

  • Compton suppression system at Penn State Radiation Science and Engineering Center. Çetiner, N. Ö.; Ünlü, K.; Brenizer, J. S. // Journal of Radioanalytical & Nuclear Chemistry;Jun2008, Vol. 276 Issue 3, p615 

    A Compton suppression system is used to reduce the contribution of scattered gamma-rays that originate within the HPGe detector to the gamma-ray spectrum. The HPGe detector is surrounded by an assembly of guard detectors, usually NaI(T1). The HPGe and NaI(T1) detectors are operated in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics