ABSTRACT
Reports on the workshop about high-current negative-ion sources for pulsed spallation neutron sources. Characteristics; Existing pulsed spallation neutron sources; Ion source requirements; Performance of present ion sources--Penning sources, magnetron sources, Budker planotron and semiplanotron sources.
ACCESSION #
4367294

 

Related Articles

  • Multi-sample negative ion source. Gelbart, W.Z.; Johnson, R.R.; Paul, M.; Shahar, Y.; Schubank, R.B.; Cifarelli, F. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1230 

    Reports on the development and construction of a cesium sputter, negative ion source at Triumf, Canada. Applicability of the ion source in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium; Stages of changer operation.

  • High power negative ion sources for fusion at the Japan Atomic Energy Research Institute (invited). Okumura, Y.; Fujiwara, Y.; Inoue, T.; Miyamoto, K.; Miyamoto, N.; Nagase, A.; Ohara, Y.; Watanabe, K. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1092 

    Re-evaluates the development of high power negative ion sources at the Japanese Atomic Energy Research Institute. Energy level of high current negative ion acceleration; Necessity of increasing gas pressure in the pure volume source; Voltage arc discharge current as a function of the operating...

  • Development of a compact negative ion source using powdery samples. Wada, Motoi; Kawano, Hiroyuki; Sasao, Mamiko // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1233 

    Reports on the development of a compact negative ion source that can be attached to a standard 1.33 inches of copper-gasket flange. Production of negative hydrogen ions using powdery samples; Percent impurity of the ion current extracted with the negative hydrogen ion; Stability of the ion source.

  • On the development of a 15 mA direct current H[sup -] multicusp source. Kuo, T.; Yuan, D.; Jayamanna, K.; McDonald, M.; Baartman, R.; Schmor, P.; Dutto, G. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1314 

    Reports on the development of a 15 mA direct current negative hydrogen multicusp source. Configuration of the single tungsten filament; Electron filtering; Gas conductivity in the extraction channel; Schematics of the extraction geometry.

  • A side extraction PIG negative ion source with a permanent magnet. Jinxiang Yu; Zhizhong Song; Xiaotang Ren // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1378 

    Reports on the development of a side extraction PIG ion source with a permanent magnet. Description of the ion source; Production of hydrogen negative ions; Production of oxygen negative ions; Production of fluorine negative ions; Discharge currents of the negative hydrogen, oxygen and fluorine...

  • Steady state operation of an ampere-class hydrogen negative ion source. Miyamoto, Naoki; Fujiwara, Yukio; Miyamoto, Kenji; Okumura, Yoshikazu // Review of Scientific Instruments;Feb2000, Vol. 71 Issue 2, p738 

    Focuses on experimental results of the long pulse operation of an ampere-class hydrogen negative ion source. Combination of a magnetically filtered multicusp plasma generator and a multiaperture extractor; Negative-ion based neutral beam injector; Measured weight loss of the tungsten filament.

  • Volume source of hydrogen negative ions based on rfelexive discharge: Theory and experiment[sup a)]. Goretsky, V.P.; Ryabtsev, A.V.; Soloshenko, I.A.; Tarasenko, A.F.; Schedrin, A.I. // Review of Scientific Instruments;Apr96, Vol. 67 Issue 4, p1622 

    Reports on the results of theoretical and experimental studies of the stationary volume source of hydrogen negative ions based on reflexive discharge. Measurements of plasma parameters; Parameters of the ion beam; Calculation of dependencies of hydrogen negative ions' current density.

  • Ion source metal-arc fault current protection circuit. deVries, G. J.; Lietzke, A. F.; van Os, C. F. A.; Stearns, J. W. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p3098 

    Ion sources can be damaged by arcs between metallic components of the source if these arcs are permitted to last. The negative-biased low-work-function converter in a surface conversion negative ion source is especially susceptible to metal-arc breakdown damage. Here an electronic circuit for...

  • Plasma cathode oxygen-ion source. Shibuya, Takehisa // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2890 

    A plasma cathode ion source has been developed to attain a long lifetime in oxygen-ion production. In this ion source, a plasma of a nonreactive gas serves as a cathode in place of a thermionic tungsten hot cathode used in the conventional Kaufman ion source. An anode ring with an annular slit...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.