TITLE

Microwave proton source development for a high-current linac injector (invited)

AUTHOR(S)
Sherman, J.; Bolme, G.; Geisik, C.; Gilpatrick, D.; Hansborough, L.; Hodgkins, D.; Lara, P.; Meyer, E.; Power, J.; Rose, C.; Sandoval, D.; Schafstall, P.; Schneider, J.D.; Stettler, M.; Stevens Jr., R.; Thuot, M.; Wright, R.; Zaugg, T.; Spence, D.
PUB. DATE
March 1996
SOURCE
Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1296
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Addresses the proton source and low-energy beam transport (LEBT) studies comprising the technical basis for the 75 keV injector. Beam space charge neutralization; Enhanced proton fraction development; Integration of the microwave proton source with the proton-beam extraction system; Voltage of hydrogen ion beam currents.
ACCESSION #
4367292

 

Related Articles

  • Single-mode or controlled multimode microwave cavity applicators for precision materials processing. Asmussen, J.; Lin, H. H.; Manring, B.; Fritz, R. // Review of Scientific Instruments;Aug1987, Vol. 58 Issue 8, p1477 

    The detailed description, the experimental demonstration, and the design of single-mode microwave cavity applicators are presented. These microwave applicators utilize an internally tuned, single-mode (or selective multimode) cylindrical cavity to focus and match microwave energy into...

  • Novel tunable reentrant microwave cavity. Migliuolo, M.; Castner, T. G. // Review of Scientific Instruments;Feb1988, Vol. 59 Issue 2, p388 

    A cylindrical reentrant cavity is discussed that features a tunable resonant frequency. The tuning range can, in principle, be as large as a factor of 3, but the present design achieved only a 28% tuning range. Such a system could be utilized where it is necessary to tune the resonant frequency...

  • Novel microwave device for nondestructive electrical characterization of semiconducting layers. Druon, C.; Tabourier, P.; Bourzgui, N.; Wacrenier, J. M. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3431 

    A microwave measurement technique, using a novel cell which enables the sheet resistance (R[Laplacian_variant]), the carrier density (n), and the mobility (μ) of epitaxial layers to be measured, is proposed. The system, controlled by a microcomputer, performs this characterization by...

  • Simple analytical model of gain saturation in microchannel plate devices. Giudicotti, L.; Bassan, M.; Pasqualotto, R.; Sardella, A. // Review of Scientific Instruments;Jan1994, Vol. 65 Issue 1, p247 

    We derive, discuss, and test against experimental data an analytical model of the gain saturation in microchannel plate (MCP) devices. By introducing a simple recharging circuit for each dynode, we extend the well-known, unsaturated gain model of Eberhardt to a microchannel operating in...

  • Space-charge effects in a velocity analyzer of variable geometry. Donoso, Guillermo; Martín, Pablo // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3381 

    A velocity analyzer of adjustable interelectrode distance has been used to study the space-charge effects on the characteristic curve. The effects become apparent for distances larger than about 10λD. The theoretical analysis considering the trapped ions in the vicinity of the entrance grid...

  • Conformal irradiation by proton beam scanning and multilayer energy filter. Sakae, Takeji; Nohtomi, Akihiro; Tsunashima, Yoshikazu; Terunuma, Toshiyuki; Sato, Masaru; Hayakawa, Yoshinori; Maruhashi, Akira // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1292 

    Using a new energy filter, three-dimensional conformal irradiation for proton therapy can be realized by monoenergetic beam scanning. It is a big advantage that the method does not necessitate energy scanning from the viewpoint of shortening the scanning time for cancer treatment of a moving...

  • First observation of Moiré fringes in a proton beam generated by a 100 fs laser pulse. Mackinnon, A. J.; Patel, P. K.; Price, D. W.; Hicks, D.; Borghesi, M.; Romagnani, L. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1917 

    High contrast Moire fringes have been observed when two gratings were inserted into a proton beam produced from the interaction of a 100 TW laser beam with a thin solid foil. Moiré fringes with modulation close to 20% were observed in protons with energies between 4 and 7 MeV. The fringes...

  • Development of a new instrument for performing microwave thermal analysis. Parkes, G. M. B.; Tada, Haruna; Bond, G.; Kumpel, Amy E.; Barnes, P. A.; Lathrop, Richard E.; Charsley, E. L.; Slanina, John B.; Nieva, Patricia; Zavracky, Paul; Miaoulis, Ioannis N.; Wong, Peter Y. // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    This article describes the design and operation of a new thermal analysis instrument which uses microwaves to simultaneously heat and detect thermally induced transformations in samples with masses in the range of 50 mg to 0.5 g. The data acquisition and control software developed for the...

  • Advanced interferometric phase and amplitude noise measurements. Rubiola, Enrico; Giordano, Vincent // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2445 

    The measurement of the close-to-the-carrier noise of two-port radio frequency and microwave devices is a relevant issue in time and frequency metrology and in some fields of electronics, physics, and optics. While phase noise is the main concern, amplitude noise is often of interest. Presently...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics