TITLE

Thermal positive-ion source developed for molecular beam detection

AUTHOR(S)
Kawano, Hiroyuki; Matsui, Seiji; Serizawa, Naoshi
PUB. DATE
March 1996
SOURCE
Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1193
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reports on the development of a thermal positive-ion source for neutral beam detection. Filament diameter of the neutral beam; Schematic diagram; Maximum sensitivities of the electrometers connected to the cylinder and Faraday cup; Optimum range temperatures observed with various sample substrates; Effect of residual gas pressure upon the thermal positive ionization.
ACCESSION #
4367252

 

Related Articles

  • Spectroscopic studies in the VUV range in electron cyclotron resonance ion sources. Jettkant, B.; Berreby, R.; Hitz, D.; Druetta, M. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1258 

    Studies emission lines in the VUV range in electron cyclotron resonance ion sources, CAPRICE and QUADRUMAFIOS. Observation of emission lines from nearly all ionization states; Comparison of ion densities between CAPRICE and QUADRUMAFIOS.

  • Spatial resolved high-energy particle diagnostic system using time-of-flight neutral particle analyzer in large helical device. Ozaki, Tetsuo; Murakami, Sadayoshi; Goncharov, Pavel; Watanabe, Tsuguhiro; Sudo, Shigeru; Narihara, Kazumichi; Tanaka, Kenji; Kubo, Shin; Simozuma, Takashi; Idei, Hiroshi; Oka, Yoshihide; Osakabe, Masaki; Takeiri, Yasuhiko; Tsumori, Katsuyoshi; Ida, Katsumi; Shoji, Mamoru; Nakanishi, Hideya; Sasao, Mamiko; Kaneko, Osamu // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1878 

    The time-of-flight-type neutral particle analyzer has an ability of horizontal scanning from 40 to 100° of the pitch angle. The information from the spatially resolved energy spectrum gives not only the ion temperature but also the information of the particle confinement and the electric...

  • Development testing of the U.S. common long pulse source at 120 kV. Vella, M. C.; Cooper, W. S.; Pincosy, P. A.; Pyle, R. V.; Weber, P. D.; Wells, R. P. // Review of Scientific Instruments;Nov88, Vol. 59 Issue 11, p2357 

    The U. S. magnetic fusion energy program has developed a single design, long-pulse neutral beam source for TFTR, MFTF-B, and DIII-D. The arc is a very compact axial magnetic line cusp. The accelerator is an actively cooled tetrode with water-cooled grid tubes of shaped molybdenum forming...

  • 120-kV testing of a 10×40-cm prototype of the U. S. common long pulse neutral beam source. Weber, P. D.; Owren, H. M.; Paterson, J. A.; Pincosy, P. A.; Pyle, R. V.; Wells, R. P.; Vella, M. C. // Review of Scientific Instruments;Nov86, Vol. 57 Issue 11, p2714 

    The 10 × 40-cm long pulse neutral beam source developed at Lawrence Berkeley Laboratory has been selected as the prototype for the design of the U. S. common long pulse source to be used on tokamak fusion test reactor (TFTR), Doublet-III, and mirror fusion test facility (MFTF-B). The long...

  • Inexpensive, automatic range-switching electrometer. Vanderschmidt, G. F. // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1988 

    A simple circuit is described which implements automatic range switching for an electrometer. The circuit may be expanded to any number of ranges and provides dead-time delay following a range switch. The operator may override automatic operation and use the circuit in conventional manual mode.

  • Rotor electrometer: New instrument for bulk matter quark search experiments. Price, John C.; Innes, Walter; Klein, Spencer; Perl, Martin // Review of Scientific Instruments;Nov86, Vol. 57 Issue 11, p2691 

    The rotor electrometer is a new instrument which we hope will make possible searches for rare fractionally charged impurities in very large quantities of matter. The ultimate goal of the project is to be able to measure the net charge of 10 mg samples of any material to an accuracy of 0.05 q[sub...

  • Ion source metal-arc fault current protection circuit. deVries, G. J.; Lietzke, A. F.; van Os, C. F. A.; Stearns, J. W. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p3098 

    Ion sources can be damaged by arcs between metallic components of the source if these arcs are permitted to last. The negative-biased low-work-function converter in a surface conversion negative ion source is especially susceptible to metal-arc breakdown damage. Here an electronic circuit for...

  • Plasma cathode oxygen-ion source. Shibuya, Takehisa // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2890 

    A plasma cathode ion source has been developed to attain a long lifetime in oxygen-ion production. In this ion source, a plasma of a nonreactive gas serves as a cathode in place of a thermionic tungsten hot cathode used in the conventional Kaufman ion source. An anode ring with an annular slit...

  • Volume source of hydrogen negative ions based on rfelexive discharge: Theory and experiment[sup a)]. Goretsky, V.P.; Ryabtsev, A.V.; Soloshenko, I.A.; Tarasenko, A.F.; Schedrin, A.I. // Review of Scientific Instruments;Apr96, Vol. 67 Issue 4, p1622 

    Reports on the results of theoretical and experimental studies of the stationary volume source of hydrogen negative ions based on reflexive discharge. Measurements of plasma parameters; Parameters of the ion beam; Calculation of dependencies of hydrogen negative ions' current density.