TITLE

Theoretical investigation of electron temperature variation across magnetic filter in a negative

AUTHOR(S)
Shirai, Mikito; Ogasawara, Masatada; Koishimine, Takehiko; Hatayama, Akiyoshi
PUB. DATE
March 1996
SOURCE
Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1085
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses results of a theoretical investigation of electron temperature variation across magnetic filter in a negative ion source. Electron loss along the magnetic field; Mean free path of electrons along the magnetic field; Determination of decay constants.
ACCESSION #
4367219

 

Related Articles

  • Electrons in the negative-ion-based NBI on JT-60 U. Kisaki, M.; Hanada, M.; Kamada, M.; Tanaka, Y.; Kobayashi, K.; Sasao, M. // AIP Conference Proceedings;3/12/2009, Vol. 1097 Issue 1, p344 

    The stripped electron trajectories in a large negative ion accelerator with multi-apertures and three acceleration stages, where non-uniform stray magnetic field is horizontally created, are calculated in the JT-60 negative ion source by a 3-D numerical code. The horizontal non-uniform stray...

  • Beam deflection by plasma grid filter current in the negative-ion source for JT-60U neutral beam injection system. Umeda, N.; Ikeda, Y.; Hanada, M.; Inoue, T.; Kawai, M.; Kazawa, M.; Komata, M.; Mogaki, K.; Ohga, T. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A529 

    In the JT-60U negative-ion-based neutral beam injection system, the effect of negative ion and electron deflection by the plasma grid (PG) magnetic filter was studied. After a long-pulse operation of up to 19 s, a local melting was observed on the beamline near the ion source, facing the...

  • New developments in rf-driven multicusp H- ion sources. Peters, J. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A528 

    rf H- sources are in permanent use for accelerators such as HERA and the SNS. The stability and H- current of these sources depend very much on the transition region between plasma and extractor. The physics of the extraction plasma region was the subject of very detailed investigations with...

  • Improvement of beam uniformity by magnetic filter optimization in a Cs-seeded large negative-ion source. Hanada, M.; Seki, T.; Takado, N.; Inoue, T.; Tobari, H.; Mizuno, T.; Hatayama, A.; Dairaku, M.; Kashiwagi, M.; Sakamoto, K.; Taniguchi, M.; Watanabe, K. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A515 

    The influence of magnetic filter configuration on the beam uniformity was examined to improve beam uniformity in a large Cs-seeded negative-ion source. By reducing the filter strength of the transverse magnetic field used in a typical negative-ion source, the beam uniformity was largely improved...

  • Negative ion transport inside collisional presheaths. Cavenago, M. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02B709 

    Modeling of negative ion sources proposed for spallation sources or neutral beam injectors must include several ion production mechanisms, in particular, for wall production, the initially backward ion motion must be reversed in the presheath to obtain extraction. An adequate analytic...

  • Effects of the weak magnetic field and electron diffusion on the spatial potential and negative ion transport in the negative ion source. Sakurabayashi, T.; Hatayama, A.; Bacal, M. // Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1770 

    The effects of the weak magnetic filed on the negative ion (H-) extraction in a negative ion source have been studied by means of a two-dimensional electrostatic particles in their self-consistent electric field. In addition, the effect of the electron diffusion across the weak magnetic field is...

  • Modeling multiple-frequency electron cyclotron resonance heating. Spencer, J. Andrew; Kim, Charlson; Kim, Jin-Soo; Evstatiev, Evstati G.; Svidzinski, Vladimir; Cluggish, Brian // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    Electron cyclotron resonance (ECR) heating influences two of the main parameters (electron temperature and, indirectly, density) that determine the charge state of the ions produced in an ECR ion source (ECRIS). Therefore, various schemes to optimize ECR heating in the ECRIS have been pursued...

  • Electron beam ion sources in the reflex mode of operation (review and progress report) (invited). Donets, E. D. // Review of Scientific Instruments;Feb2000, Vol. 71 Issue 2, p810 

    Focuses on reflex mode of electron beam ion source (EBIS) operation. Repeated use of electrons; Decrease of a consumed electric power compared to the electron beam power in the normal mode of EBIS operation; Phase transition observation; Energy and spatial distribution of the string electrons;...

  • Deduction of the absolute negative ion density by using planar and cylindrical electric probes simultaneously. Chung, Kyu-Sun; Kado, Shinichiro // Physics of Plasmas;Oct2006, Vol. 13 Issue 10, p104509 

    Analytic formulas are derived for the deduction of the absolute density of negative ions by using the measured electron temperatures and saturation currents of positive ions and negative charges from current-voltage curves taken by planar and cylindrical probes at two different pressures without...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library