ABSTRACT
Presents results of a performance test of a large negative ion source for a JT-60U negative-ion-based neutral beam injector. Design features of the ion source; Pulse duration; Uniformity of the source plasma; Extraction of negative ions; Full power test.
ACCESSION #
4367194

 

Related Articles

  • High-current surface-plasma negative-ion sources with geometrical focusing. Belchenko, Yu. I.; Kupriyanov, A. S. // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p484 

    Long-pulsed surface plasma multiaperture models with hydrogen negative-ions output of up to 1 A and with an average current density of 60 mA/cm² are described. The experimental and simulated negative-ion production efficiencies of pure hydrogen and cesiated surface-plasma sources with...

  • Experiments on a reflex-type sheet plasma negative-ion source. Ando, A.; Kuroda, T.; Oka, Y.; Kaneko, O.; Karita, A.; Kawamoto, T. // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p442 

    Negative hydrogen ions are extracted from a reflex-type sheet plasma. Electron density and temperature profiles are measured with changing the filling gas pressure, and they are optimized to the H[sup -] production at the optimum gas pressure. The optimum gas pressure is 5 m Torr for the...

  • Origin of extracted negative ions by 3D PIC-MCC modeling. Surface vs Volume comparison. Mochalskyy, S.; Lifschitz, A. F.; Minea, T. // AIP Conference Proceedings;9/26/2011, Vol. 1390 Issue 1, p30 

    The development of a high performance negative ion (NI) source constitutes a crucial step in the construction of Neutral Beam Injector (NBI) of the future fusion reactor ITER. NI source should deliver 40 A of H- (or D-), which is a technical and scientific challenge, and requires a deeper...

  • Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source. Nakano, Haruhisa; Tsumori, Katsuyoshi; Nagaoka, Kenichi; Shibuya, Masayuki; Fantz, Ursel; Kisaki, Masashi; Ikeda, Katsunori; Osakabe, Masaki; Kaneko, Osamu; Asano, Eiji; Kondo, Tomoki; Sato, Mamoru; Komada, Seiji; Sekiguchi, Haruo; Takeiri, Yasuhiko // AIP Conference Proceedings;9/26/2011, Vol. 1390 Issue 1, p359 

    A Cavity Ring-Down (CRD) system was applied to measure the density of negative hydrogen ion (H-) in vicinity of extraction surface in the H- source for the development of neutral beam injector on Large Helical Device (LHD). The density measurement with sampling time of 50 ms was carried out. The...

  • Plasma diagnostic tools for optimizing negative hydrogen ion sources. Fantz, U.; Falter, H. D.; Franzen, P.; Speth, E.; Hemsworth, R.; Boilson, D.; Krylov, A. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A516 

    The powerful diagnostic tool of optical emission spectroscopy is used to measure the plasma parameters in negative hydrogen ion sources based on the surface mechanism. Results for electron temperature, electron density, atomic-to-molecular hydrogen density ratio, and gas temperature are...

  • Commissioning of the negative ion testbed ELISE. Kraus, W.; Fantz, U.; Franzen, P.; Fröschle, M.; Heinemann, B.; Martens, C.; Riedl, R.; Wünderlich, D. // AIP Conference Proceedings;Feb2013, Vol. 1515 Issue 1, p129 

    The tests of the large RF driven sources for the ITER neutral beam system will be started on the neutral beam test facility PRIMA in Padua not before 2015. As an important intermediate step a half size ITER source has been designed at Max Planck Institute for Plasma Physics (IPP) and will be...

  • Numerical analysis of primary electrons in a tandem-type negative ion source. Katoh, K.; Takado, N.; Hatayama, A.; Hanada, M.; Seki, T.; Inoue, T. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A535 

    To clarify the physical mechanism of the plasma spatial nonuniformity observed in tandem-type negative-ion sources, the primary electron-transport process has been analyzed by a three-dimensional Monte Carlo simulation code. In the model, equations of motion for electrons are numerically solved....

  • Modeling of an Inductive Negative Ion Source for Neutral Beam Injection. Hagelaar, G. J. M.; Boeuf, J.-P.; Simonin, A. // AIP Conference Proceedings;3/19/2008, Vol. 993 Issue 1, p55 

    We present a self-consistent two-dimensional model of a high-power inductive plasma source for negative ion production in hydrogen. The model is quasi-neutral and describes the transport and chemistry of different particle species by fluid equations including inertia and viscosity terms, coupled...

  • Negative-ion plasma sources. Sheehan, D. P.; Rynn, N. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1369 

    Three designs for negative-ion plasma sources are described. Two sources utilize metal hexafluorides such as SF[sub 6] and WF[sub 6] to scavenge electrons from electron-ion plasmas and the third relies upon surface ionization of alkali halide salts on heated alumina and zirconia. SF[sub 6]...