TITLE

Computational studies for a multiple-frequency electron cyclotron resonance ion source (abstract)

AUTHOR(S)
Alton, G.D.
PUB. DATE
March 1996
SOURCE
Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p989
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses an abstract for a multiple-frequency electron cyclotron resonance ion source. Processes that affect the maximum electron energy; Technique to overcome the stochastic heating of the electrons; Simulation of magnetic field distributions using particle-in-cell codes.
ACCESSION #
4367183

 

Related Articles

  • Ion Beam Extraction from Large Bore 11 to 13 GHz ECR Ion Source with a Pair of Cylindrically Comb-Shaped Magnetic Fields. Watanabe, T.; Satani, T.; Matsui, Y.; Sato, F.; Kato, Y.; Iida, T. // AIP Conference Proceedings;11/3/2008, Vol. 1066 Issue 1, p533 

    We have developed a large bore electron cyclotron resonance (ECR) ion source with cylindrically comb-shaped magnetic field configuration to realize high current density and comparatively large bore ion beam which can be used for beam processes under low pressure and low microwave power. It is...

  • Broad Ion Beam Extraction from Large Bore ECR Ion Source with Cylindrically Comb-Shaped Magnetic Fields Configuration by Feeding Simultaneously 11 to 13 GHz and 2.45 GHz Microwaves. Kato, Y.; Satani, T.; Matsui, Y.; Watanabe, T.; Muramatsu, M.; Tanaka, K.; Asaji, T.; Kitagawa, A.; Sato, F.; Iida, T. // AIP Conference Proceedings;11/3/2008, Vol. 1066 Issue 1, p348 

    We tried to enlarge the operation window of an electron cyclotron resonance (ECR) ion source for producing the ECR plasma confined by cylindrically comb-shaped magnetic field, and for extracting the broad ion beam under the low pressures and low microwave powers. The magnetic field by permanent...

  • Deduction of edge electron density with multiply charged ions in ORNL volume-type electron cyclotron resonance ion source. You, H.-J.; Woo, H.-J.; Chung, K.-S.; Liu, Y.; Meyer, F. W.; Lho, T.; Lee, M.-J. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02A319 

    The electron densities in the argon plasmas of the ORNL 6 GHz electron cyclotron resonance (ECR) ion source with a flat central magnetic field have been deduced from the ion branches of the electric probe current-voltage curves measured in the edge region of the plasmas. To overcome the...

  • An Electron Cyclotron Resonance Ion Source with Cylindrically Comb-Shaped Magnetic Field Configuration. Kato, Yushi; Sasaki, Hiroshi; Asaji, Toyohisa; Kubo, Takashi; Sato, Fuminobu; Iida, Toshiyuki // AIP Conference Proceedings;2006, Vol. 866 Issue 1, p373 

    A new concept on magnetic field of plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of comb-shaped magnet...

  • On a simulation of ion confinement in ECRIS plasmas. Mironov, V.; Stiebing, K. E. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p626 

    A particle-in-cell code has been developed for modeling the charged particle three-dimensional dynamics in the magnetic field of an electron cyclotron resonance ion source (ECRIS). The code incorporates the leap-frog particle pusher and Takizuka-Abé's method for simulating the small-angle...

  • Status of the pulsed magnetic field electron cyclotron resonance ion source. Mühle, C.; Ratzinger, U.; Bleuel, W.; Jöst, G.; Leible, K.; Schennach, S.; Wolf, B. H. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p1078 

    Synchrotrons like the heavy-ion synchrotron SIS at GSI need an efficient low duty cycle injector (typical 1-pulse/s and 200-µs pulse length). To improve the peak current, an electron cyclotron resonance (ECR) ion source has been designed using a pulsed magnetic field (PuMa) to force ion...

  • Improved design of cusp-type electron-cyclotron resonance ion sources. Ishii, S.; Kato, Y. // Review of Scientific Instruments;Jul1995, Vol. 66 Issue 7, p3873 

    Discusses the design of an ion source of electron-cyclotron resonance using cusp magnetic field. Plasma generation by the whistler wave; Proposed design of the ion source; Additional electron emitted by the repeller of low work function; Atomic flux from the cylindrical surface.

  • Electron cyclotron resonance ion source frequency scaling and radial confinement in a quadrupole magnetic field. Pu, Y. K.; Halverson, W.; Petty, C.; Smatlak, D.; Torti, R. // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p276 

    Experiments have been conducted on Constance B to study transport properties in electron cyclotron resonance (ECR) heated plasmas of high-charge-state neon ions. Measurements were made of confinement parallel and perpendicular to the magnetic field at heating frequencies of 10.5 and 14 GHz, and...

  • Electron cyclotron resonance ion source one-dimensional fluid modeling. Edgell, Dana H.; Kim, Jin-Soo; Bogatu, Ioan N.; Pardo, Richard C.; Vondrasek, Richard C. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p641 

    A one-dimensional (ID) fluid computer model for multiple ion species in an electron cyclotron resonance ion source (ECRIS) plasma has been developed. The ions species are assumed to be highly collisionally coupled and are treated using ID fluid equations. The non-Maxwellian anisotropic electron...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics