TITLE

Magnet tests and status of the superconducting electron cyclotron resonance source SERSE

AUTHOR(S)
Ciavola, G.; Gammino, S.; Cafici, M.; Castro, M.; Chines, F.; Marletta, S.; Alessandria, F.; Bourg, F.; Briand, P.; Melin, G.; Lagnier, R.; Seyfert, P.; Gaggero, G.; Losasso, M.; Penco, R.
PUB. DATE
March 1996
SOURCE
Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p889
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses results of magnetic tests and the status of the superconducting electron cyclotron resonance source SERSE. Modification of the SERSE magnetic system; Minimization of the coupling between the two input waveguides; B-minimum trap and the magnetic field measurements; Measurement of maximum hexapolar field.
ACCESSION #
4367150

 

Related Articles

  • Effect of discharge microwave frequency on electron temperature of electron cyclotron resonance plasma. Kawai, Y.; Suzuki, T.; Saburi, T.; Fujii, Y. // Review of Scientific Instruments;Mar2001, Vol. 72 Issue 3, p1666 

    The characteristics of argon electron cyclotron resonance plasma discharged by 7.0, 8.0, and 9.4 GHz microwaves were investigated. Experiments were conducted in a fixed magnetic field. It was found that the electron temperatures T[sub e] exhibited a trend of T[sub e7.0]

  • Design aspects of the Debrecen ECR ion source. Biri, S.; Vamosi, J. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p971 

    Reports on the design and construction of the Debrecen electron cyclotron resonance ion source. Functions of the coil and hexapole of the magnetic system; Function of the independent cooling system; Functions of the extraction-focusing electrode system; Capabilities of the TrapCAD code.

  • A compact coaxial electron cyclotron resonance plasma source. Baskaran, R.; Jain, S.K.; Ramamurthy, S.S. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1243 

    Reports on the construction of a compact coaxial electron cyclotron resonance plasma source for plasma deposition experiments. Profiles of the magnetic field in the plasma chamber; Plasma density as a function of the solenoid coil current; Electron temperature; Plasma parameters for the conical...

  • Extraction studies on electron cyclotron resonance ion sources. Leroy, R.; Mandin, J.; Bertrand, P.; Lecesne, N.; Pacquet, J.Y.; Robert, E.; Sortais, P.; Villari, A.C.C. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1350 

    Compares the results of an ion beam extraction experiment using electron cyclotron resonance ion sources and numerical simulation. Influence of the axial magnetic field on multicharged ion beam if the space charge during the acceleration is not compensated; Effect of the decrease of the plasma...

  • Optimization of the Halbach-type magnetic multipole for an electron cyclotron resonance ion source. Suominen, P.; Tarvainen, O.; Koivisto, H.; Hitz, D. // Review of Scientific Instruments;Jan2004, Vol. 75 Issue 1, p59 

    An efficient electron cyclotron resonance ion source requires microwave frequency as high as possible. At the same time, the magnetic field has to meet experimentally found rules. The magnetic field configuration required for efficient operation is provided by a combination of solenoid and...

  • Characteristics of electron cyclotron resonance plasma generated in a rectangular waveguide by high-power microwave. Mishra, Lekha Nath; Shibata, Kanetoshi; Ito, Hiroaki; Yugami, Noboru; Nishida, Yasushi // Review of Scientific Instruments;Jan2004, Vol. 75 Issue 1, p84 

    A new source for the generation of overdense plasma is developed using an electron cyclotron resonance (ECR) technique in a rectangular waveguide by a high-power (1 kW) microwave of frequency 2.45 GHz. The characteristics of the plasma for Ar gas are presented, including a large surface area to...

  • Maximum x-ray energy from compact electron cyclotron resonance based source of x rays. RouilleĀ“, C.; Serebrennikov, K.; Bacal, M. // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2287 

    The x-ray spectra from an electron cyclotron resonance argon plasma produced in a compact magnetic trap, containing a tungsten target, are reported. The maximum attainable x-ray energy was recorded for different magnetic field configurations and energies higher than 300 keV were found. The...

  • Sputtering-assisted production of multicharged boron ions from solid material in a 2.45 GHz... Kato, Yushi; Ishii, Shigeyuki // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2171 

    Reports on the production of multiply charged boron ions and extraction from 2.45 GHz electron cyclotron resonance (ECR) ion source without gaseous feedstocks. Selection of argon as operating gas; Increase in the extracted boron ion current as target nears the ECR zone; Total boron ion current.

  • Efficient production of a [sup 48]Ca beam from oxide material in an electron cyclotron resonance... Harkewicz, R. // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2176 

    Describes a technique which allows the highly efficient production of an isotopically enriched calcium beam from oxide material with reduction by zirconium in an electron cyclotron resonance ion source. Beam quality yielded by the method; Sizes of radial ports of the ion source; Design of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics