TITLE

Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength

AUTHOR(S)
Bottlang, Michael; Doornink, Josef; Fitzpatrick, Daniel C.; Madey, Steven M.
PUB. DATE
August 2009
SOURCE
Journal of Bone & Joint Surgery, American Volume;Aug2009, Vol. 91-A Issue 8, p1985
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Several strategies to reduce construct stiffness have been proposed to promote secondary bone healing following fracture fixation with locked bridge plating constructs. However, stiffness reduction is typically gained at the cost of construct strength. In the present study, we tested whether a novel strategy for stiffness reduction, termed far cortical locking, can significantly reduce the stiffness of a locked plating construct while retaining its strength. Methods: Locked plating constructs and far cortical locking constructs were tested in a diaphyseal bridge plating model of the non-osteoporotic femoral diaphysis to determine construct stiffness in axial compression, torsion, and bending. Subsequently, constructs were dynamically loaded until failure in each loading mode to determine construct strength and failure modes. Finally, failure tests were repeated in a validated model of the osteoporotic femoral diaphysis to determine construct strength and failure modes in a worst-case scenario of bridge plating in osteoporotic bone. Results: Compared with the locked plating constructs, the initial stiffness of far cortical locking constructs was 88% lower in axial compression (p <0.001), 58% lower in torsion (p <0.001), and 29% lower in bending (p <0.001). Compared with the locked plating constructs, the strength of far cortical locking constructs was 7% lower (p = 0.005) and 16% lower (p < 0.001) under axial compression in the non-osteoporotic and osteoporotic diaphysis, respectively. However, far cortical locking constructs were 54% stronger (p < 0.001) and 9% stronger (p = 0.04) under torsion and 21% stronger (p < 0.001) and 20% stronger (p = 0.02) under bending than locked plating constructs in the non-osteoporotic and osteoporotic diaphysis, respectively. Within the initial stiffness range, far cortical locking constructs generated nearly parallel interfragmentary motion. Locked plating constructs generated significantly less motion at the near cortex adjacent to the plate than at the far cortex (p < 0.01). Conclusions: Far cortical locking significantly reduces the axial stiffness of a locked plating construct. This gain in flexibility causes only a modest reduction in axial strength and increased torsional and bending strength. Clinical Relevance: Far cortical locking may provide a novel bridge plating strategy to enhance interfragmentary motion for the promotion of secondary bone healing while retaining sufficient construct strength.
ACCESSION #
43637152

 

Related Articles

  • Volumetric analysis of corticocancellous bones using CT data. Krappinger, Dietmar; Linde, Astrid; Rosenberger, Ralf; Glodny, Bernhard; Blauth, Michael; Niederwanger, Christian // Skeletal Radiology;May2012, Vol. 41 Issue 5, p503 

    Objective: To present a method for an automated volumetric analysis of corticocancellous bones such as the superior pubic ramus using CT data and to assess the reliability of this method. Materials and methods: Computed tomography scans of a consecutive series of 250 patients were analyzed. A...

  • Clinical utility of tomosynthesis in suspected scaphoid fracture. A pilot study. Geijer, Mats; Börjesson, Annika M.; Göthlin, Jan H. // Skeletal Radiology;Jul2011, Vol. 40 Issue 7, p863 

    Background: Radiography alone will not detect all scaphoid fractures. There is a reported prevalence between 9 and 33% of occult scaphoid fractures. The evidence-based literature suggests that magnetic resonance imaging (MRI) is the most suitable secondary imaging modality due to the ability to...

  • APPLICATION OF LOCAL VIBRATIONS IN DELAYED AND NON-UNION FRACTURES: A CASE STUDY. SALLÌ, M.; TROMBETTA, C.; ABUNDO, P.; TRAVISI, T.; ROSATO, N.; FOTI, C. // Journal of Orthopedics;Jan-Apr2013, Vol. 5 Issue 1, p5 

    A case study was performed to assess the efficacy of local vibration treatments (LV) in delayed-union and non-union fractures through therapeutic exercise vibration (TEV) by analyzing the radiological trend. A male patient presenting a right tibial fracture was treated with TEV. A monthly...

  • Treatment of Intra-articular Comminuted Os Calcis Fractures. Hatzokos, Ippokratis; Karataglis, Dimitrios; Papadopoulos, Pericles; Dimitriou, Chris; Christodoulou, Anastasios; Pournaras, John // Orthopedics;Jan2006, Vol. 29 Issue 1, p25 

    Focuses on a study which presented an operative technique for the management of comminuted intra-articular os calcis fractures. Materials and methods; Clinical and radiographic evaluation conducted; Results of the study.

  • Conservative management of thoracolumbar and lumbar spine compression and burst fractures: functional and radiographic outcomes in 136 cases treated by closed reduction and casting. Weninger, Patrick; Schultz, Arthur; Hertz, Harald // Archives of Orthopaedic & Trauma Surgery;Feb2009, Vol. 129 Issue 2, p207 

    Both fractures of the lumbar spine and at the thoracolumbar junction are quite common. The treatment of these fracture types is discussed controversially. Some authors advocate surgical treatment even in fractures without neurologic compromise while other series report good results after...

  • TWO AND THREE-DIMENSIONAL COMPUTED TOMOGRAPHY FOR THE CLASSIFICATION AND MANAGEMENT OF DISTAL HUMERAL FRACTURES. Doornberg, Job; Lindenhovius, Anneluuk; Kloen, Peter; van Dijk, C. Niek; Zurakowski, David; Ring, David // Journal of Bone & Joint Surgery, American Volume;Aug2006, Vol. 88-A Issue 8, p1795 

    Background: Complex fractures of the distal part of the humerus can be difficult to characterize on plain radiographs and two-dimensional computed tomography scans. We tested the hypothesis that three-dimensional reconstructions of computed tomography scans improve the reliability and accuracy...

  • Effect of Ovariectomy, Malnutrition and Glucocorticoid Application on Bone Properties in Sheep: A Pilot Study. Lill, C. A.; Fluegel, A. K.; Schneider, E. // Osteoporosis International;Jun2002, Vol. 13 Issue 6, p480 

    : The demographic changes in the human population continue to lead to an increasing incidence of osteoporosis. The main clinical symptom of osteoporosis is fracture. Fracture fixation in osteoporosis is frequently complicated by failure of fixation. There is a great need for a large-animal model...

  • Radiographic evaluation of acute scaphoid fractures. Parajuli, B.; Uprety, S. // Journal of Institute of Medicine;Aug2015, Vol. 37 Issue 2, p106 

    Introduction: Scaphoid fracture is the commonest carpal bone fracture. Various radiographic views have been proposed for diagnosing it. This study was conducted to determine which radiographic view/s among five different views showed scaphoid fracture consistently. Methods: This prospective...

  • Getting all the breaks--fractures, splints, and casts.  // Current Health 1;Dec97, Vol. 21 Issue 4, p26 

    Presents information about fractured bone. Three kinds of fractures; Signs and symptoms of a fractured bone; Tips on how to handle a person who have fractured bone; Its healing process. INSETS: What's your fracture IQ?;When you're too far from help--splint.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library