Cooling Health-Care Technology

Beaty, Don
July 2009
Heating/Piping/Air Conditioning Engineering;Jul2009, Vol. 81 Issue 7, p22
The article focuses on the cooling of information-technology (IT) systems in health-care facilities. It explores the differences between IT and procedure rooms, which have been considered as the major categories of technology in health-care facilities. It also provides suggestions on how to select cooling equipment and systems for IT spaces.


Related Articles

  • 10 things to remember about radiant cooling systems. McDonell, Geoff // Consulting-Specifying Engineer;Nov2007, Vol. 42 Issue 5, p58 

    The article offers points to remember when delineating ceiling radiant cooling systems. The key points to remember in radiant cooling includes reducing the cooling loads, concentrate on the building envelope to reduce the effect of outdoor climate fluctuations and space temperature design...

  • Reactions of Chiller Maintain Efficiency.  // Air Conditioning Heating & Refrigeration News;5/1/2006, Vol. 228 Issue 1, p10 

    The article offers information on the advantages of variable speed technology to users of industrial chillers as well as chiller manufacturers. Variable speed, when applied to a refrigeration compressor works to always fit the compressor output to the demand for cooling. The compressor always...

  • Cooling Load Calculations For Radiant Systems. BAUMAN, FRED; JING JUAN (DOVE); SCHIAVON, STEFANO // ASHRAE Journal;Dec2013, Vol. 55 Issue 12, p20 

    The article discusses the benefits of radiant cooling and heating systems over the all-air distribution systems in terms of energy efficiency. It refers to a research evidence that reveals the big difference of sensible zone cooling loads for radiant systems from the cooling loads for...

  • How to Efficiently Cool or Condense. Demakos, Peter // Process Cooling & Equipment;May2004, p18 

    Focuses on the usage of wet-surface air coolers for auxiliary fluid cooling and vapor condensing. Basic principle of operation; Air requirements; Maintenance and repair; Design specification; Water use and disposal issues.

  • Dehumidification.  // ACR News: Air Conditioning & Refrigeration News;Feb2010, Vol. 26 Issue 5, p19 

    The article discusses the process of dehumidification. It elaborates on the potential problems posed by humidity which include overloading of cooling plants due to high latent load, equipment difficulties in packaging areas with high moisture levels, and spoilage of raw materials in unprotected...

  • Variable-Frequency Drives. Tomczyk, John // Air Conditioning Heating & Refrigeration News;10/5/2009, Vol. 238 Issue 5, p16 

    The article focuses on the significance of variable-frequency drives (VFD) in the creation of heating, air conditioning and refrigeration (HVACR) systems. It notes that systems with variable-speed fan motors can deliver variable air volume (VAV) flows to match the heating and cooling demands of...

  • Accuracy Tests for Simulations of VAV Dual- Duct, Single-Zone, Four-Pipe Fan-Coil, and Four-Pipe Induction Air-Handling Systems. G. K. Yuill; J. S. Haberl; J. S. Caldwell // ASHRAE Transactions;2006, Vol. 112 Issue 2, p377 

    This paper provides a method for verifying the accuracy of computer models that simulate the performance of the airhandling components of four types of heating, ventilating, and air-conditioning systems: the dual fan VAV dual-duct system, the single-zone system, the four-pipe fan coil system,...

  • Mixing Old and New. Amborn, Randy // ASHRAE Journal;Nov2006, Vol. 48 Issue 11, pB4 

    The article focuses on the renovation of TMPC Reality Corp.'s buildings, formerly Park Towers in the U.S. Part of the renovation of the two buildings included a building automation system controlling the floors and air-handling units. Here, TPMC chose BACnet protocol system. With the use of the...

  • Comparison between Underfloor Supply and Overhead Supply Ventilation Designs for Data Center High-Density Clusters. Schmidt, Roger R.; Iyengar, Madhusudan // ASHRAE Transactions;2007, Vol. 113 Issue 1, p115 

    Data center facilities that house computer equipment represent a high capital investment and are typically designed to function for at least a few years, often without any down time. The computer equipment is usually designed with the assumption of rack air inlet temperatures in the 20-30° C...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics