TITLE

Analysis of the optical reconstruction of shearograms using oblique illumination

AUTHOR(S)
Ng, T.W.
PUB. DATE
August 1997
SOURCE
Review of Scientific Instruments;Aug1997, Vol. 68 Issue 8, p3125
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Analyzes the optical reconstruction of shearograms using oblique illumination. Optical reconstruction setup; Fringe formation in shearography; Numerical analysis of shearogram reconstruction efficacy using oblique illumination.
ACCESSION #
4358615

 

Related Articles

  • Optical Test & Measurement Equipment.  // Laser Focus World;Mar2009 Buyers Guide, p261 

    The article lists suppliers of optical test and measurement equipment including Moeller-Wedel Optical GmbH, AMO WaveFront Sciences LLC and Hamamatsu Corp.

  • Devices for maintaining optical access in high-temperature coal combustion environments. II. Sonic and supersonic flow regions. Cook, Robert L.; Lineberry, John T. // Review of Scientific Instruments;Feb1994, Vol. 65 Issue 2, p466 

    Application of optical diagnostic techniques and instruments in the high-temperature coal combustion environments of large-scale facilities requires a clear optical path into and out of the particle-laden gas stream for long periods of time. In this paper, we describe devices for making...

  • Optical measurements of structure and orientation in sheared carbon-nanotube suspensions. Hobbie, E. K.; Wang, H.; Kim, H.; Han, C. C.; Grulke, E. A.; Obrzut, J. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1244 

    We describe an optical metrology for measuring shear-induced structure and orientation in dilute dispersions of multiwalled carbon nanotubes. Small-angle polarized light scattering and optical microscopy are combined in situ to quantify the structural anisotropy of multiwalled carbon nanotubes...

  • Calibration of optical tweezers with differential interference contrast signals. Capitanio, M.; Romano, G.; Ballerini, R.; Giuntini, M.; Pavone, F. S.; Dunlap, D.; Finzi, L. // Review of Scientific Instruments;Apr2002, Vol. 73 Issue 4, p1687 

    A comparison of different calibration methods for optical tweezers with the differential interference contrast (DIC) technique was performed to establish the uses and the advantages of each method. A detailed experimental and theoretical analysis of each method was performed with emphasis on the...

  • Improved apparatus for picosecond pump-and-probe optical measurements. Capinski, William S.; Maris, Humphrey J. // Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p1720 

    Presents an improved method for making pump-and-probe optical measurements in the picosecond to nanosecond time range. Use of a pump light pulse to excite the sample; Investigation of the resulting changes in the optical properties; Development of an apparatus that utilizes a single-mode...

  • Development of an infrared absorption measurement method using the photothermal deflection effect of thallium bromide iodide (KRS-5): Measurement with a stepped-scan Fourier transform infrared spectrometer. Minato, Hideyuki; Ishido, Yoshinari // Review of Scientific Instruments;Jul2001, Vol. 72 Issue 7, p2889 

    An optical system was produced experimentally for infrared absorption measurements based on the photothermal deflection effect of solid material (KRS-5), which does not require a cell for the medium as does absorption measurement using the photothermal deflection effect of liquids. In this...

  • A holographic dual-channel interferometer. Sharma, Amit K.; Chhachhia, D. P.; Mahajan, C. G.; Aggarwal, A. K. // Current Science (00113891);8/10/2006, Vol. 91 Issue 3, p269 

    A holographic, optics-based dual-channel interferometer with an in-built phase-shifting element is described. The interferometer can be used for testing two different phase objects simultaneously and independently. Additionally, a single object could be studied simultaneously in two different...

  • Multiple-wavelength interferometry measures large seamented mirrors. North-Morris, Michael // Laser Focus World;Oct2005, Vol. 41 Issue 10, pS3 

    The article reports on the ability of multiple-wavelength interferometry to provide a fast, high-quality alternative to contact profiling and scanning techniques. The technique provides a dynamic range of millimeters while maintaining the high resolution of a single wavelength interferometer...

  • Mirror dispersion control of a hollow fiber supercontinuum. Sansone, G.; Steinmeyer, G.; Vozzi, C.; Stagira, S.; Nisoli, M.; De Silvestri, S.; Starke, K.; Ristau, D.; Schenkel, B.; Biegert, J.; Gosteva, A.; Keller, U. // Applied Physics B: Lasers & Optics;Mar2004, Vol. 78 Issue 5, p551 

    Ultrabroadband chirped mirrors with a bandwidth of 270 THz have been manufactured using the BASIC design approach. These mirrors were used to compress the supercon- tinuum of cascaded hollow fibers down to 4.6 fs. The pulse duration was measured with spectral phase interferometry for direct...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library