TITLE

Narrow bandpass multilayer x-ray monochromator

AUTHOR(S)
Sammar, A.; Krastev, K.; Andre, J.-M.; Barchewitz, R.
PUB. DATE
August 1997
SOURCE
Review of Scientific Instruments;Aug1997, Vol. 68 Issue 8, p2969
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Proposes a method to reduce the bandpass of soft x-ray multilayer Bragg reflectors. Components and theoretical principles of the narrow bandpass monochromator; Methods used to design the monochromator; Performance testing of the device.
ACCESSION #
4358585

 

Related Articles

  • Angular distribution measurement of fragment ions from a molecule using a new beamline consisting of a Grasshopper monochromator. Saito, Norio; Suzuki, Isao H.; Onuki, Hideo; Nishi, Morotake // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2190 

    Optical characteristics of a new beamline consisting of a premirror, a Grasshopper monochromator, and a refocusing mirror have been investigated. The intensity of the monochromatic soft x-ray was estimated to be about 10[sup 8] photons/(s 100 mA ) at 500 eV with the storage electron energy of...

  • High resolution in the soft x-ray range from a toroidal grating monochromator. Reich, T.; Hussain, Z.; Moler, E.; Blackwell, M.; Kaindl, G.; Shirley, D. A.; Howells, M. R. // Review of Scientific Instruments;Sep93, Vol. 64 Issue 9, p2552 

    A resolving power, E/δE, of ≥ 13 000 has been achieved with the modified 6 m/160° toroidal grating monochromator (TGM) installed on Beam Line 8-1 at the Stanford Synchrotron Radiation Laboratory. The resolving power of the TGM was increased by replacing the entrance and exit slits...

  • Low pass filter for soft x-ray monochromators. Terminello, L. J.; McLean, A. B.; Santoni, A.; Spiller, E.; Himpsel, F. J. // Review of Scientific Instruments;Jun90, Vol. 61 Issue 6, p1626 

    A low pass filter is described that suppresses higher-order diffraction light from vacuum ultraviolet and soft x-ray monochromators. It consists of a triple silicon reflector with the angle of incidence matched to the desired photon energy cutoff. The performance is calculated and tested...

  • Variable groove-spaced grating monochromator for soft x-ray emission spectroscopy at CAMD/LSU. Asfaw, A.; Ederer, D.L.; Zhou, L.; Lin, L.; Osborn, K.; Callcott, T.A.; Miyano, K.E.; Morikawa, E. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1627 

    Describes a variable groove-spaced grating monochromator for soft x-ray emission that was commissioned at the Center for Advanced Microstructures and Devices at Louisiana State University in Baton Rouge, Louisiana. Optical design; TNT beamline; Photon flux; Resolution.

  • Performance of a materials science facility at the Photon Factory: Soft x-ray beamline BL 13C... Shimada, H.; Matsubayashi, N.; Imamura, M.; Sato, T.; Yoshimura, Y.; Hayakawa, T.; Takehira, K.; Toyoshima, A.; Tanaka, K.; Nishijima, A. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1780 

    Describes the performance data of an undulator soft x-ray beamline based on the cylindrical element monochromator concept. Outline of the beamline; Intensity and resolution; Application of the facility.

  • A simple spherical grating by-pass monochromator dedicated to soft x-ray emission spectroscopy Ghiringhelli, G.; Tagliaferri, A.; Braicovich, L.; Brookes, N. B. // Review of Scientific Instruments;Apr98, Vol. 69 Issue 4, p1610 

    Presents the spherical grating Polarized Light Improved Flux Efficiency Monochromator for soft x-ray emission spectroscopy. Description of the instrument; Analysis of the optical performance; Limiting factor of the device.

  • High resolution and symmetry resolved core-level spectroscopy using soft x-ray undulator (invited). Yagishita, A.; Shigemasa, E. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1383 

    The performance of a soft x-ray undulator beamline equipped with a 10 m grazing incidence monochromator is described. Several experimental results are presented to exemplify the good performance. The decomposition of photoabsorption spectra of CO and O[sub 2] into their component molecular...

  • Performance of the cooling system for the soft x-ray double-crystal monochromator at the Photon Factory. Funabashi, M.; Nomura, M.; Kitajima, Y.; Yokoyama, T.; Ohta, T.; Kuroda, H. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1983 

    A crystal cooling system was designed and tested successfully for the soft x-ray double-crystal monochromator in an ultrahigh-vacuum environment at the Photon Factory. The temperature rise at the surface of the InSb first crystal is reduced to less than 45 °C at an average stored current of...

  • Monochromators for the undulator U49 at the BESSY II storage ring. Petersen, H.; Senf, F.; Schafers, F.; Bahrdt, J. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1777 

    Describes the construction of two types of monochromators for use on the planned soft x-ray undulator U49 of the BESSY II storage ring. Design goal and boundary conditions; Plane grating monochromator beamline; Spherical grating monochromator beamline.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics