Magnetic microscopy using a liquid nitrogen cooled YBa[sub 2]Cu[sub 3]O[sub 7] superconducting

Black, R.C.; Mathai, A.; Wellstood, F.C.; Dantsker, E.; Miklich, A.H.; Nemeth, D.T.; Kingston, J.J.; Clarke, J.
April 1993
Applied Physics Letters;4/26/1993, Vol. 62 Issue 17, p2128
Academic Journal
Evaluates magnetic microscopy through liquid nitrogen cooled YBa[sub 2]Cu[sub 3]O[sub 7] superconducting quantum interference device. Production of two-dimensional images of magnetic fields; Development of magnetic flux microscope; Presentation of magnetic images.


Related Articles

  • Low-frequency noise and linearity of a YBa...superconducting quantum interference device... Krey, S.; Barthelmess, H.-J. // Journal of Applied Physics;12/1/1999, Vol. 86 Issue 11, p6602 

    Presents information on a study which investigated the noise and flux sensing area of a field cooled direct current superconducting quantum interference device magnetometer. Application of magnetometer; Use of liquid nitrogen in measuring the noise of the magnetometer.

  • High-T[sub c] superconducting quantum interference device observation of heat-affected zone in a spot-welded Fe–Cr–Ni system. Watanabe, Yoshimi; Kang, S. H.; Chan, J. W.; Morris Jr., J. W.; Clarke, John // Applied Physics Letters;9/1/2003, Vol. 83 Issue 9, p1878 

    A study was carried out to observe a heat-affected zone (HAZ) in a deformed Fe–Cr–Ni system containing α[sup ′] martensite using high-T[sub c] superconducting quantum interference device (SQUID) microscopy. Microstructure and remanent magnetization images were studied by...

  • Magnetic properties of Sr-ferrite dot arrays by electron beam lithography. Liu, Xiaoxi; Itoh, Fumitake // Journal of Applied Physics;5/15/2003, Vol. 93 Issue 10, p7423 

    We have successfully prepared Sr-ferrite dot arrays with perpendicular magnetic anisotropy by electron beam lithography. Virgin magnetic configurations detected by magnetic force microscopy (MFM) show single domain configuration for a 0.5 μm dot, while multidomain configurations are found for...

  • Single layer YBa[sub 2]Cu[sub 3]O[sub 7] radio frequency SQUID magnetometers with direct-coupled.... Zhang, Y.; Kruger, U.; Kutzner, R.; Wordenweber, R.; Schubert, J.; Zander, W.; Sodtke, E.; Braginski, A.I. // Applied Physics Letters;12/26/1994, Vol. 65 Issue 26, p3380 

    Examines the magnetic field resolution of superconducting quantum interference device (SQUID) magnetometers in liquid nitrogen. Attainment of flux noise spectral density in SQUID; Pattern of washer structures by optical lithography; Measurement of SQUID within multilayered mumetal magnetic...

  • Magnetic imaging of YBCO on RABiTS using a squid microscope. Nielsen, A. P.; Kerchner, H. R.; Lobb, C. J.; Barbara, P. // AIP Conference Proceedings;2002, Vol. 614 Issue 1, p1134 

    Using a scanning SQUID microscope we have magnetically imaged YBCO films grown upon Rolling-Assisted Biaxial Textured Substrates (RABiTS). The measurements clearly show a strong (about 3 Oe) and non-uniform spontaneous magnetization due to the Ni-based substrate. The YBCO film on a ferromagnetic...

  • Thermalized ground state of artificial kagome spin ice building blocks. Arnalds, Unnar B.; Farhan, Alan; Chopdekar, Rajesh V.; Kapaklis, Vassilios; Balan, Ana; Papaioannou, Evangelos Th.; Ahlberg, Martina; Nolting, Frithjof; Heyderman, Laura J.; Hjörvarsson, Björgvin // Applied Physics Letters;9/10/2012, Vol. 101 Issue 11, p112404 

    We present a direct magnetic imaging study on the thermal macrospin ordering of artificial kagome spin ice building blocks. Using photoemission electron microscopy, employing x-ray magnetic circular dichroism, we are able to resolve the single domain magnetic nature of the macrospins and...

  • Magnetic force microscopy of epitaxial magnetite films through the Verwey transition. Lee, A. K. H.; Jayathilaka, P. B.; Bauer, C. A.; Monti, M. C.; Markert, J. T.; de Lozanne, A.; Miller, Casey W. // Applied Physics Letters;10/18/2010, Vol. 97 Issue 16, p162502 

    Magnetic force microscopy was performed on 300 nm thick magnetite films grown epitaxially on MgO (001) at temperatures ranging from well below to well above the Verwey transition temperature, TV. Frequency shift images were acquired at different locations on the sample as temperature was...

  • High-temperature superconducting quantum interference device with cooled LC resonant circuit for measuring alternating magnetic fields with improved signal-to-noise ratio. Qiu, Longqing; Zhang, Yi; Krause, Hans-Joachim; Braginski, Alex I.; Usoskin, Alexander // Review of Scientific Instruments;May2007, Vol. 78 Issue 5, p054701 

    Certain applications of superconducting quantum interference devices (SQUIDs) require a magnetic field measurement only in a very narrow frequency range. In order to selectively improve the alternating-current (ac) magnetic field sensitivity of a high-temperature superconductor SQUID for a...

  • Position noise in scanning superconducting quantum interference device microscopy. Lee, Su-Young; Matthews, J.; Wellstood, F. C. // Applied Physics Letters;6/14/2004, Vol. 84 Issue 24, p5001 

    Experimentally obtained magnetic field images contain not only magnetic field noise, but also uncertainty in the position at which the data points are recorded. Such position noise degrades the images where the magnetic field gradients are strongest. Our high-Tc scanning superconducting quantum...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics