TITLE

Simultaneous resolution of spectral and temporal properties of UV and visible fluorescence using

AUTHOR(S)
Kelly, Lisa A.; Trunk, John G.; Polewski, Krzysztof; Sutherland, John C.
PUB. DATE
February 1995
SOURCE
Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1496
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the position-sensitive single-photon detector of the fluorescence spectrometer assembled at the U9B beamline of the National Synchrotron Light Source to allow simultaneous multiwavelength and time-resolved fluorescence detection. System of operation of the spectrometer; Derivation of the centroid position of the photon-induced electron cascade.
ACCESSION #
4331061

 

Related Articles

  • Design and development of a rapid acquisition laser-based fluorometer with simultaneous spectral and temporal resolution. Pitts, Jonathan D.; Mycek, Mary-Ann // Review of Scientific Instruments;Jul2001, Vol. 72 Issue 7, p3061 

    We report the design, development, and characterization of a sensitive, time-resolved fluorescence spectrometer capable of measuring fluorescence spectra and transient decays simultaneously, with data acquisition times less than 1 s. The spectrometer, a portable fluorescence lifetime...

  • High-speed multichannel photon counter for time-resolved laser spectroscopy. Baba, Hiroshi; Hoshina, Satoshi; Sakurai, Katsumi; Takeuchi, Nobuo // Review of Scientific Instruments;Oct85, Vol. 56 Issue 10, p1926 

    A versatile, high-speed multichannel counter, which has maximum temporal resolution Δt=30 ns and channel length up to 4095, has been developed for various kinds of time-resolved laser spectroscopic measurements. High speed, large counting capacity, low cost for fabrication, and ease of...

  • A system for time-resolved laser fluorescence spectroscopy with multiple picosecond gating. Cubeddu, R.; Docchio, F.; Liu, W. Q.; Ramponi, R.; Taroni, P. // Review of Scientific Instruments;Oct88, Vol. 59 Issue 10, p2254 

    A computer-controlled system for time-resolved fluorescence spectroscopy is described. The system provides the simultaneous acquisition of the fluorescence decay curve, of the time-integrated emission spectrum, and of two time-gated spectra. Gating within the fluorescence decay is provided by...

  • Space-time resolving vacuum ultraviolet spectrometer based on a rotating polyhedral mirror. Lin, Xiaodong; Xiaodong Lin; Xie, Jikang; Jikang Xie // Review of Scientific Instruments;May2000, Vol. 71 Issue 5 

    Using a rotating polyhedral mirror and a vacuum ultraviolet (VUV) monochromater, a space-time resolving VUV diagnostic system is developed. Measurement of the O VI (103.2 nm) radiation on the HT-6M tokamak shows that the time resolution of the system is better than 4 ms and the space resolution...

  • Time-resolved evanescent wave-induced fluorescence anisotropy for the determination of molecular conformational changes of proteins at an interface. Gee, Michelle L.; Lensun, Levie; Smith, Trevor A.; Scholes, Colin A. // European Biophysics Journal;2004, Vol. 33 Issue 2, p130 

    We have shown that the molecular conformation of a protein at an interface can be probed spatially using time-resolved evanescent wave-induced fluorescence spectroscopic (TREWIFS) techniques. Specifically, by varying the penetration depth of the evanescent field, variable-angle TREWIFS, coupled...

  • An integrated instrumentation for light-scattering and time-resolved fluorescence measurements. Musolino, M.; Cubeddu, R.; Pifferi, A.; Taroni, P.; Lago, P.; Rovati, L. // Review of Scientific Instruments;Mar95, Vol. 66 Issue 3, p2405 

    Describes an integrated instrumentation which combines in the same system static and dynamic laser light scattering and time-resolved fluorescence spectroscopy on the same sample contained in a thermostated cuvette. Overall time resolution of fluorescence measurements; Benefits in the use of...

  • Pulsed laser photolysis kinetics study of the O(3P)+ClO reaction. Nicovich, J. M.; Wine, P. H.; Ravishankara, A. R. // Journal of Chemical Physics;11/1/1988, Vol. 89 Issue 9, p5670 

    A pulsed laser photolysis technique has been employed to study the kinetics of the important stratospheric reaction O+ClO→k1Cl+O2 in N2 buffer gas over the temperature and pressure ranges 231–367 K and 25–500 Torr. 351 nm pulsed laser photolysis of Cl2/O3/N2 mixtures...

  • Nanosecond time-resolved vacuum ultraviolet spectrometer for ion diode spectroscopy. Nash, T.; Noack, D.; Filuk, A. B. // Review of Scientific Instruments;Sep93, Vol. 64 Issue 9, p2493 

    A 1-m normal incidence spectrometer has been modified for use as a diagnostic of ion diode plasmas. To improve instrumental sensitivity, an elliptical mirror images an anode surface plasma onto the entrance slit of an f/10 normal incidence spectrometer. The detector is a time-resolving copper...

  • Time-resolved measurement of energy and species of an intense pulsed ion beam. Matsuzawa, T.; Takahashi, A.; Masugata, K.; Ito, M.; Matsui, M.; Yatsui, K. // Review of Scientific Instruments;Dec1985, Vol. 56 Issue 12, p2279 

    A time-resolvable Thomson-parabola spectrometer is developed employing a microchannel-plate image intensifier, which acts as a high-speed shutter (∼5 ns) by gating the applied voltage. Using such a spectrometer, we have achieved the measurement of temporal behavior of beam energy for...

Share

Read the Article

Courtesy of

Sorry, but this item is not currently available from your library.