TITLE

Soft x-ray emission spectrometer for undulator radiation

AUTHOR(S)
Shin, S.; Agui, A.; Fujisawa, M.; Tezuka, Y.; Ishii, T.; Hirai, N.
PUB. DATE
February 1995
SOURCE
Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1584
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes an experimental system for high-resolution soft x-ray emission spectroscopy that was designed to be attached to the undulator beamlines. Geometry of the spectrometer; Focusing properties; Resolution obtained by the system.
ACCESSION #
4330668

 

Related Articles

  • Performance of a very high resolution soft x-ray beamline BL25SU with a twin-helical undulator at SPring-8. Saitoh, Y.; Kimura, H.; Suzuki, Y.; Nakatani, T.; Matsushita, T.; Muro, T.; Miyahara, T.; Fujisawa, M.; Soda, K.; Ueda, S.; Harada, H.; Kotsugi, M.; Sekiyama, A.; Suga, S. // Review of Scientific Instruments;Sep2000, Vol. 71 Issue 9 

    We report on the excellent performance of a newly constructed soft x-ray helical undulator beamline BL25SU of SPring-8 for photon energies 500-1800 eV. The full beamline was designed to perform very high resolution soft x-ray spectroscopy of solids with using high brilliance, highly circularly...

  • High-resolution soft x-ray spectrometer for the NSTX tokamak. Beiersdorfer, P.; Bitter, M.; May, M. J.; Roquemore, L. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1974 

    A high-resolution spectrometer for measuring the soft x-ray emission (7-24 Ã…) has been implemented on the National Spherical Tokamak Experiment (NSTX). The instrument will be used to study the K-shell spectra of O, Ne, and Mg as well as the L-shell spectra of Fe and Ni and to calibrate...

  • Radial profiles of 2p-ls heliumlike oxygen lines measured from the compact helical system using a vacuum crystal spectrometer Muto, Sadatsugu; Morita, Shigeru; Kondo, Katsumi // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1039 

    Discusses the design and construction of a Johann type vacuum crystal spectrometer to measure soft x-ray lines in the region in which 2p-1s transitions of oxygen and 3l-2l' transitions of metallic impurities exist. Structure of the spectrometer; Detector; Radial profiles of helium-like oxygen...

  • Precise measurement technology of soft-x-ray spectrum using dual transmission grating spectrometer. Jiamin Yang; Yaonan Ding; Wenghai Zhang; Jiyan Zhang; Zhijian Zheng // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4268 

    A novel transmission grating spectrometer, called a dual-transmission grating spectrometer, has been designed and established. This spectrometer adopts two transmission gratings to disperse x rays twice, which suppresses the overlap of the grating higher-order diffraction, cuts out the transfer...

  • An electron imaging approach to soft-x-ray transmission spectromicroscopy. De Stasio, Gelsomina; Lorusso, G.F.; Droubay, T.; Kohli, M.; Muralt, P.; Perfetti, P.; Margaritondo, G.; Kelly, T.F.; Tonner, B.P. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p737 

    Discusses the testing of a soft-x-ray transmission spectromicroscopy technique. Testing of silicon features over silicon nitride substrates; Lateral and energy resolutions; Transmission curves as a function of photon energy; Chemical nature of the contrast; Optimum thickness of the Au photocathode.

  • Development of a high-efficiency high-resolution particle-induced x-ray emission system for chemical state analysis of environmental samples. Hasegawa, J.; Tada, T.; Oguri, Y.; Hayashi, M.; Toriyama, T.; Kawabata, T.; Masai, K. // Review of Scientific Instruments;Jul2007, Vol. 78 Issue 7, p073105 

    We have developed a high-efficiency high-resolution particle-induced x-ray emission (PIXE) system employing a von Hamos–type crystal spectrometer for a chemical state identification of trace elements in environmental samples. The energy resolution of the system was determined to be about...

  • PittCon 2000 in Review.  // Spectroscopy;May2000, Vol. 15 Issue 5, p38 

    Describes the products featured at the Pittsburgh Conference on spectroscopy instruments which was held in New Orleans, Louisiana from March 12 to 17, 2002. AAS6-Vario atomic absorption system from A.J. Jena Analytical Products; AI 1200/2200 atomic absorption and plasma emission spectrometer...

  • XRF spectrometer.  // Spectroscopy;Apr2006, Vol. 21 Issue 4, p50 

    The article evaluates PANalytical's Axios-Minerals wavelength dispersive, sequential X-ray fluorescence spectrometer and offers information on design, key features and applications.

  • Imaging transmission grating spectrometer for magnetic fusion experiments. Blagojevic, B.; Stutman, D.; Finkenthal, M.; Moos, H. W.; Kaita, R.; Majeski, R. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1988 

    The Johns Hopkins Plasma Spectroscopy Group is developing a transmission grating based imaging spectrometer for the ultrasoft x-ray [(USXR), 10-300 Ã…] range. The spectrometer will be integrated into an impurity diagnostic package for magnetic fusion experiments, which provides time and space...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics