TITLE

Theoretical and experimental studies of the ZnSe/CuInSe[sub 2] heterojunction band offset

AUTHOR(S)
Nelson, Art J.; Schwerdtfeger, C.R.; Su-Huai Wei; Zunger, Alex; Rioux, D.; Patel, R.; Hochst, Hartmut
PUB. DATE
May 1993
SOURCE
Applied Physics Letters;5/17/1993, Vol. 62 Issue 20, p2557
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the ZnSe/CuInSe[sub 2] heterojunction valence band offset using synchrotron radiation soft x-ray photoemission spectroscopy. Demonstration of common anion rule failure; Measurement of photoemission after growth to observe valence band changes.
ACCESSION #
4323200

 

Related Articles

  • Soft x-ray source for BEPC synchcrotron radiation laboratory. Cui, M. Q.; Xu, W. X.; Liu, L. B.; Heng, H. G.; Tang, E. S.; Sun, Z. Y.; Qi, L. R.; Xian, D. C. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1905 

    A set of fine-focusing soft x-ray sources has been manufactured to meet the requirements of research and development work at the BEPC Synchrotron Radiation Laboratory. The electrical and optical characteristics of the source as well as preliminary experiments on contact microscopy performed with...

  • A magnetizing system for dichroism measurements in soft x-ray emission excited by synchrotron... Dallera, C.; Ghiringhelli, G.; Braicovich, L. // Review of Scientific Instruments;Feb1996, Vol. 67 Issue 2, p355 

    Discusses the design and performance of a magnetic circuit suitable for magnetizing solid samples in the measurements of soft x-ray emission dichroism excited by synchrotron radiation. Layout of the magnetic circuit; Technical details.

  • A novel intensity interferometer for synchrotron radiation in the vacuum ultraviolet and soft x-ray regions. Tai, RenZhong; Takayama, Yasuhiro; Takaya, Noriko; Miyahara, Tsuneaki; Yamamoto, Shigeru; Sugiyama, Hiroshi; Urakawa, Junji; Hayano, Hitoshi; Ando, Masami // Review of Scientific Instruments;Mar2000, Vol. 71 Issue 3 

    Based upon a method of Hanbury-Brown and Twiss, while considering the nonstationary characteristics of synchrotron radiation (SR), a novel optical intensity interferometer was constructed to extract the true two-photon correlation of soft x-ray SR. This intensity interferometer consists of an...

  • Synthesis of ammonium and organic compounds from N[sub 2],H[sub 2]O vapor, and CO[sub 2] gas mixtures by synchrotron radiation induced photochemical reactions at atmospheric pressure and at room temperature. Utsumi, Yuichi; Hattori, Tadashi // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1387 

    Several compound materials were synthesized from N[sub 2],H[sub 2]O vapor, and CO[sub 2] gas mixtures using synchrotron radiation induced photochemical reactions at atmospheric pressure and at room temperature. Ammonium and nitrogen oxides were successfully synthesized from N[sub 2],H[sub 2]O...

  • X-ray image monitoring using a new soft x-ray plate: Ag/chalcogenide film. Utsugi, Yasushi; Kakuchi, Masami; Maezawa, Hideki // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2295 

    A new soft x°ray plate of Ag/chalcogenide film is proposed, which offers in situ monitoring of high-resolution x-ray images. Soft x-ray exposure of synchrotron and undulator radiation causes color change in the Ag/chalcogenide film, capable of yielding a potential resolution, on the order of...

  • Design and fabrication of condenser zone plates for a soft x-ray microscopy beamline in Hefei. Su, Yong-gang; Hong, Yi-lin; Fu, Shao-jun; Tao, Xiao-ming; Zhang, Yun-wu // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2041 

    A synchrotron radiation soft x-ray beamline for scanning microscopy mainly, is being constructed in Hefei. It contains a linear monochromator consisting of a diaphragm of 7 μm diameter and one of three condenser zone plates (CZP). The three CZPs are for three overlapping wavelength ranges...

  • Structural uniformity of multilayered tungsten-carbon Bragg reflectors prepared by rf magnetron sputtering. Takenaka, Hisataka; Takaoka, Hidetoshi; Ishii, Yoshikazu; Hashizume, Hiroo // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2021 

    Large area W-C multilayered films used as Bragg reflectors for SR in soft and hard x-ray regions are fabricated using alternate sputter deposition. The structure uniformity of these films is examined by our newly designed triple-axis diffractometer for large area x-ray diffraction topography...

  • A dedicated soft x-ray beamline for x-ray absorption spectroscopy (abstract). Morrison, T. I.; Lien, N. C.; Bunker, B. A.; Sayers, D. E.; Heald, S. M.; Fareria, L.; Scrofani, J. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1991 

    We will present the design, capabilities, and characteristics of the recently commissioned Beamline X-11B at the National Synchrotron Light Source. This line has been designed to optimally function in the "soft" x-ray regime (1-5 keV), but can easily be used up to the design limit of the storage...

  • Status of insertion device and beamline design for ELETTRA. Rosei, R.; Walker, R. P. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1809 

    ELETTRA is a new ultrahigh-brightness VUV/soft x-ray synchrotron radiation facility under construction by Sincrotrone Trieste in Italy. The main features of the project and its status are described. Details of the expected properties of the different types of radiation source are presented, and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics