TITLE

Electron holography in the study of the leakage field of magnetic force microscope sensor tips

AUTHOR(S)
Matteucci, G.; Muccini, M.; Hartmann, U.
PUB. DATE
April 1993
SOURCE
Applied Physics Letters;4/12/1993, Vol. 62 Issue 15, p1839
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Investigates the leakage magnetic field produced by sharp ferromagnetic probes. Application of electron holography; Obtainment of interference fringes; Evaluation of the phase difference in the simulated map of the dipole field.
ACCESSION #
4323117

 

Related Articles

  • Noise Measurement of Interacting Ferromagnetic Particles with High Resolution Hall Microprobes. Komatsu, K.; L'Hôte, D.; Nakamae, S.; Ladieu, F.; Mosser, V.; Kerlain, A.; Konczykowski, M.; Dubois, E.; Dupuis, V.; Perzynski, R. // AIP Conference Proceedings;4/23/2009, Vol. 1129 Issue 1, p153 

    We present our first experimental determination of the magnetic noise of a superspin-glass made of <1 pico-liter frozen ferrofluid. The measurements were performed with a local magnetic field sensor based on Hall microprobes operated with the spinning current technique. The results obtained,...

  • Electrical measurements with a SQUlD susceptometer. Wong, H. K. // Review of Scientific Instruments;Jun91, Vol. 62 Issue 6, p1664 

    We describe the design of a probe that can be inserted into a SQUID susceptometer (S.H.E. model VTS-805) for electrical measurements at variable temperature and high magnetic field. This top-loading probe allows multisample measurements and rapid sample replacement without disturbing the...

  • Scanning Hall probe microscopy with shear force distance control. Schweinbo¨ck, Thomas; Weiss, Dieter; Lipinski, Martin; Eberl, Karl // Journal of Applied Physics;5/1/2000, Vol. 87 Issue 9, p6496 

    We describe a new type of scanning Hall probe microscope operating at room temperature for quantitative and noninvasive measurements of magnetic stray fields. The probe-sample distance is controlled by piezoelectrical detection of the shear forces acting on an oscillating cantilever. The Hall...

  • Thin-film magnetic patterns in an external field. Bryant, Paul; Suhl, Harry // Applied Physics Letters;5/29/1989, Vol. 54 Issue 22, p2224 

    The behavior of ideally soft ferromagnetic films in the presence of a weak coplanar magnetic field is explored by the method of characteristics. Solutions are found which have no internal field or in some cases have field-free zones. Results are specifically given for circular and elliptic...

  • Spiral Vortices in Ferromagnets. Borisov, A. B. // JETP Letters;3/10/2001, Vol. 73 Issue 5, p242 

    New types of magnetic defects in two-dimensional ferromagnets are found in the exchange approximation, and the influence of magnetic anisotropy on their structure is analyzed. � 2001 MAIK �Nauka / Interperiodica�.

  • Photothermally modulated stray field imaging of magnetic materials. Hoppstadter, D.; Netzelmann, U. // Applied Physics Letters;7/25/1994, Vol. 65 Issue 4, p499 

    Presents a technique for ferromagnetic material imaging using photothermally modulated stray fields of the surfaces. Use of focused laser beam heating; Measurement of magnetic flux changes; Lateral resolution of the images achieved.

  • Helical magnetic configuration formed by using shaped ferromagnetic material. Nishimura, K.; Komori, A.; Koide, Y.; Sato, N. // Review of Scientific Instruments;Oct88, Vol. 59 Issue 10, p2169 

    Formation of a straight helical magnetic field is attempted by using ferromagnetic material. A shaped ferromagnetic cylinder, which modifies an external uniform magnetic field, is demonstrated to realize an l=3 helical magnetic field that is suitable for plasma experiments. The measured values...

  • Magnetic and transport behaviors of La[sub 0.5](Sr[sub 0.53]Ca[sub 0.47])[sub 0.5]MnO[sub 3] under pressure, magnetic field, and Fe doping. Sun, J. R.; Liu, Z. X.; Yeung, C. F.; Chan, H. N.; Wong, H. K.; Li, R. W.; Shen, B. G. // Journal of Applied Physics;3/1/2002, Vol. 91 Issue 5, p3139 

    Effects of pressure, magnetic field, and Mn-site doping on the magnetic structure and resistive behavior of La[sub 0.5](Sr[sub 0.53]Ca[sub 0.47])[sub 0.5]Mn[sub 1 - χFe[sub χ (0≤ χ ≤ 0.10) have been experimentally studied. The system experiences two magnetic transitions...

  • High accuracy magnetic field measurements with a Hall probe. Schott, C.; Popovic, R.S.; Alberti, S.; Tran, M.Q. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2703 

    Describes a silicon-based temperature stabilized axial Hall probe with an absolute accuracy of +/-40 ppm in the range from 0 to 6 T. Hall probe configuration; Magnetic field configuration; Calibration procedure.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics