ABSTRACT
Describes a photon detector with spatial and temporal resolution capabilities. Components of the detector; Quantum efficiency of the instrument; Maximum data rate for a pixel; Determination of the absolute time of a single event within 100 nanoseconds; Single pixel response.
ACCESSION #
4321231

 

Related Articles

  • Status Of The PHase Analyzer SYstem Project. Menk, Ralf-Hendrik; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p949 

    The objective of the presented project, which started 3 years ago under the patronage of the European commission, is the thorough study and the full exploitation of the ‘diffraction enhanced imaging’ (DEI) technique. DEI exploits phase effects and allows in principle low absorbing...

  • An Ultra-High-Speed Detector for Synchrotron Radiation Research. Bussat, J.-M.; Fadley, C. S.; Hussain, Z.; Kay, A. W.; Lebedev, G.; Ludewigt, B. A.; Meddeler, G.; Nambu, A.; Press, M.; Spieler, H.; Turko, B.; West, M.; Zizka, G.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p945 

    An ultra high-speed, one-dimensional multi-channel detector for electrons and soft x-ray photons has been developed to permit full utilization of fluxes from third- and fourth-generation synchrotron radiation sources. The detector has 768 channels of buffered counters with a maximum linear...

  • Measurement of photons via conversion pairs in $\sqrt{s_{NN}}$ =200 GeV Au+Au collisions with the PHENIX experiment at RHIC. Dahms, T. // European Physical Journal C -- Particles & Fields;Jan2007, Vol. 49 Issue 1, p249 

    Thermal photons can provide information on the temperature of the new state of matter created at RHIC. In the pT region of 1–3 GeV/c thermal photons are expected to be the dominant direct photon source. Therefore, a possible excess compared to a pure decay photon signal due to a thermal...

  • Monte Carlo simulation of NaI(TL) detector in a shadow-shield scanning bed whole-body monitor for uniform and axial cavity activity distribution in a BOMAB phantom. Akar, D. K.; Patni, H. K.; Nadar, M. Y.; Ghare, V. P.; Rao, D. D. // Radiation Protection Dosimetry;Jul2013, Vol. 155 Issue 3, p292 

    This study presents the simulation results for 10.16 cm diameter and 7.62 cm thickness NaI(Tl) detector response, which is housed in a partially shielded scanning bed whole-body monitor (WBM), due to activity distributed in the axial cavities provided in the Indian reference BOMAB phantom....

  • Kβ/Kα X-Ray Intensity Ratios for Co, Ni, Cu, and Zn in Phthalocyanines Complexes. BALTAS, H.; ERTUGRAL, B.; KANTAR, C.; SASMAZ, S.; YILMAZ, E.; CEVIK, U. // Acta Physica Polonica, A.;Jun2011, Vol. 119 Issue 6, p764 

    The Kβ=Kα X-ray intensity ratios of Co, Ni, Cu and Zn in metalophthalocyanines complexes have been studied. Co, Ni, Cu and Zn elements have been excited by using 59.5 keV photons emitted by 50 mCi 241Am radioactive source. K X-rays emitted by samples have been counted by a Si(Li) detector...

  • Note: A sampling method for quantum random bit generation. Yu, L. M.; Yang, M. J.; Wang, P. X.; Kawata, S. // Review of Scientific Instruments;Apr2010, Vol. 81 Issue 4, p046107 

    In this note, we present a new sampling method for quantum random bit generation. The new method requires only one single-photon detector and does not measure the time slots of emitted photons. A binary random bit sequence obtained is independent on the time slot of the pulses and the precision...

  • A Study on Determination of an Optimized Detector for Single Photon Emission Computed Tomography. Khoshakhlagh, Mohammad; Islamian, Jalil Pirayesh; Abedi, Mohammad; Mahmoudian, Babak; Mardanshahi, Ali Reza // World Journal of Nuclear Medicine;Jan-Apr2016, Vol. 15 Issue 1, p12 

    The detector is a critical component of the single photon emission computed tomography (SPECT) imaging system for giving accurate information from the exact pattern of radionuclide distribution in the target organ. The SIMIND Monte Carlo program was utilized for the simulation of a Siemen's dual...

  • Counting Your Single NIR Photons. Forsyth, Keith // R&D Magazine;Jan2007, Vol. 49 Issue 1, p21 

    The article presents information on the SU-02-SPC, an analytical instrument developed by Sensors Unlimited Inc. to make counting or timing single near-infrared photons easier. Light signals are connected to the instrument through an FC optical fiber connector. Its mode of operations include...

  • Experimental study of direct photon emission in K/it− → π−π0γ decay using ISTRA+ detector. Uvarov, V. A.; Akimenko, S. A.; Bolotov, V. N.; Britvich, G. I.; Datsko, K. V.; Duk, V. A.; Filin, A. P.; Inyakin, A. V.; Khmelnikov, V. A.; Konstantinov, A. S.; Konstantinov, V. F.; Korolkov, I. Ya.; Laptev, S. V.; Leontiev, V. M.; Novikov, V. P.; Obraztsov, V. F.; Polyakov, V. A.; Polyarush, A. Yu.; Romanovsky, V. I.; Ronjin, V. M. // Physics of Atomic Nuclei;Jan2006, Vol. 69 Issue 1, p26 

    The branching ratio in the charged-pion-kinetic-energy region of 55 to 90 MeV for the direct photon emission in the K − → π−π0γ decay has been measured using in-flight decays detected with the ISTRA+ setup operating in the 25-GeV/ c negative secondary beam of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics