TITLE

7The electromagnetic modes of a helical resonator

AUTHOR(S)
Diehl, Robert; Wheatley, David M.; Castner, T.G.
PUB. DATE
November 1996
SOURCE
Review of Scientific Instruments;Nov96, Vol. 67 Issue 11, p3904
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents a study that probed the electric fields of the helical resonator using metallic copper and heavily doped silicon (Si):phosphorous (P) disks. Fundamental frequency and odd harmonics; Measurement of the relative frequency shift and the change in quality factor; Insertion of the disk as a probe mounted on a dielectric support rod.
ACCESSION #
4321023

 

Related Articles

  • On Internal Mode Resonance in a Nonlinearly Vibrating Volumetrically Charged Dielectric Drop. Shiryaeva, S.O. // Technical Physics;Feb2003, Vol. 48 Issue 2, p152 

    In the approximation quadratic in the amplitude of an arbitrary initial deformation of an equilibrium spherical uniformly (volumetrically) charged drop of a dielectric liquid, an analytical expression for the drop surface generatrix as a function of time is derived in the case when the drop...

  • Dielectric measurements with helical resonators. Deri, R. J. // Review of Scientific Instruments;Jan1986, Vol. 57 Issue 1, p82 

    A method for measuring dielectric properties with helical resonators is presented and analyzed. The procedure is based on an equivalent circuit model which treats the helix as a length of transmission line; an experimental approach for determination of the model parameters is demonstrated....

  • Resonators for accurate dielectric measurements in conducting liquids Hamelin, Jean; Mehl, James B.; Moldover, Michael R. // Review of Scientific Instruments;Jan1998, Vol. 69 Issue 1, p255 

    Describes a modified radio-frequency resonator for accurate measurements of zero-frequency dielectric constant of conducting liquid. Analysis of resonance frequency using lumped-component equivalent circuit; Link between resonance frequency and quality factor of resonance; Determination of...

  • Measurement of microwave dielectric properties using the parallel-plate dielectric resonance technique. Sheen, Jyh; Bhalla, A. S.; Cross, L. E. // Journal of Applied Physics;9/15/1994, Vol. 76 Issue 6, p3935 

    Reports on the adoption of a modified field model of the parallel-plate open dielectric resonator to measure the dielectric constants and loss tangents of low loss materials. Expression for the electric fields in each region; Results of dielectric constant measurements.

  • Dielectric properties of pulsed-laser deposited SrTiO[sub3] films at microwave frequency ranges. Hong, J. P.; Kwak, J. S.; Kim, C. O.; Park, S. J.; Sok, J. H.; Lee, E. H. // Journal of Applied Physics;9/15/2000, Vol. 88 Issue 6, p3592 

    Studies the dielectric constant and loss tangent of SrTiO[sub 3] thin films under the influence of an applied dc voltage. Use of a gold resonator with a flip-chip capacitor at cryogenic temperatures for the measurement.

  • Frequency Dependence of the Permittivity of a Dielectric Obtained by a Resonator Method. Salov, V.; Zabolotsky, A.; Gazizov, T. // Russian Physics Journal;Oct2014, Vol. 57 Issue 6, p855 

    The article illustrates a method and an algorithm for the calculation of the dielectric permittivity in a wide range of frequencies. It mentions that the technique is based on the determination of frequencies of natural oscillations of a rectangular volume resonator with dielectric sample. It...

  • Effective properties of split-ring resonator metamaterials using measured scattering parameters: Effect of gap orientation. Varadan, Vasundara V.; Tellakula, Anilkumar R. // Journal of Applied Physics;8/1/2006, Vol. 100 Issue 3, p034910 

    This paper presents experimental S-parameter data (amplitude and phase) in the 8–26 GHz range for split-ring resonator (SRR) metamaterial samples exhibiting electric (E) and/or magnetic (H) resonances at 10.4 GHz depending on the orientation of the gaps of the SRRs with respect to the E...

  • Enhanced sensitivity for high-pressure EPR using dielectric resonators. Bromberg, Steven E.; Chan, I. Y. // Review of Scientific Instruments;Jul1992, Vol. 63 Issue 7, p3670 

    We present a modified Merrill–Bassett diamond anvil cell for performing electron paramagnetic resonance (EPR) experiments under high pressure. The design centers on two mutually coupled TiO2 dielectric resonators mounted close to the diamonds. This configuration produces a tangential...

  • Transparent miniature dielectric resonator for electron paramagnetic resonance experiments. Blank, Aharon; Stavitski, Eli; Levanon, Haim; Gubaydullin, Firdus // Review of Scientific Instruments;May2003, Vol. 74 Issue 5, p2853 

    Presents a novel miniature dielectric resonator for X-band electron paramagnetic resonance experiments. Features of the resonator based on a single crystal of KTaO[sub 3]; Consideration of several configurations of resonators; Presentation of the findings in terms of both experimental and...

  • Experimental evidence of resonant effective permittivity in a dielectric metamaterial. Lepetit, T.; Akmansoy, É.; Ganne, J.-P. // Journal of Applied Physics;Jan2011, Vol. 109 Issue 2, p023115 

    We designed and fabricated a dielectric metamaterial consisting of one set of high permittivity resonators. We experimentally showed that this metamaterial exhibits resonant effective permittivity, issued from the second mode of Mie resonances of these resonators. Therefore, metamaterials...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics